Design of filter to reject motion artifact of pulse oximetry

被引:41
|
作者
Lee, J
Jung, W
Kang, I
Kim, Y
Lee, G
机构
[1] Gyeongsang Natl Univ, Dept Elect Engn, Bioelect Lab, Kyungnam 660701, Gyeongsangnamdo, South Korea
[2] YONAM Coll Engn, Dept Comp & Informat Technol, Jinju 660750, Kyungnam, South Korea
关键词
oxygen saturation; biomedical signal processing; motion artifact filter;
D O I
10.1016/s0920-5489(03)00077-1
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of the pulse oximeter, an instrument which non-invasively measures oxygen saturation in blood, is influenced by a patient's respiration or movement. Generally, the frequency band of the motion artifact signal generated from the patient's movement is overlapped with that of the patient's pulse wave which is measured by the received light sensor. Accordingly, it is difficult to filter the motion artifact of the pulse wave by using a filter which has a cut-off frequency that is fixed. In this study, the motion artifact is removed using the filter bank and the matched filter. Compared with traditional adaptive filter methods, the ratio variation is 50% lower than that of the moving average filter, allowing more stable measurement of oxygen saturation despite the patient's movement. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 50 条
  • [31] EFFECT OF MOTION ARTIFACT ON THE FUNCTION OF 4 PULSE OXIMETERS
    LANGTON, JA
    HANNING, CD
    BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) : P289 - P290
  • [32] Mitigation of Motion Artifacts in Pulse Oximetry through Redundant Sensors
    Alkhoury, Ludvik
    Choi, Jiwon
    Wang, Chizhong
    Mahoney, Sean
    Shender, Barry S.
    Hrebien, Leonid
    Kam, Moshe
    2022 SIGNAL PROCESSING: ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS (SPA), 2022, : 46 - 51
  • [33] Motion-resistant pulse oximetry during circumcision in neonates
    Sahni, R
    Gupta, A
    Rosen, TS
    PEDIATRIC RESEARCH, 2000, 47 (04) : 430A - 430A
  • [34] Discrimination by Design: Is It Time to Recalibrate Interpretation of Pulse Oximetry?
    Barreto, Jessica A.
    Moynihan, Katie M.
    PEDIATRIC CRITICAL CARE MEDICINE, 2023, 24 (06) : 517 - 521
  • [35] Terminal Design of Nontouch Queryable Photoelectric Pulse Oximetry
    Ju, Lan
    Meng, Qingbin
    PROCEEDINGS OF THE 2015 INTERNATIONAL SYMPOSIUM ON COMPUTERS & INFORMATICS, 2015, 13 : 1663 - 1670
  • [36] Sensor design of new type reflectance pulse oximetry
    Liu, Y
    Zhu, JG
    Luo, YH
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 98 - 102
  • [37] Design of a low-cost instrument for pulse oximetry
    Ferrera, F. Magadan
    Ferrero, F. J.
    Blanco, C.
    Viera, J. C.
    Vega, M. G.
    Blanco, J. R.
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 573 - +
  • [38] PULSE OXIMETRY - TECHNICAL ASPECTS OF MACHINE-DESIGN
    POLOGE, JA
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1987, 25 (03) : 137 - 153
  • [39] Using an Adaptive Filter to Remove ECG Motion Artifact Interference
    Bai, Li-Ming
    Fan, Ming-Hui
    Feng, Chen-Hui
    Wang, Liang-Hung
    2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-TAIWAN (ICCE-TW), 2018,
  • [40] PULSE OXIMETRY
    TREMPER, KK
    CHEST, 1989, 95 (04) : 713 - 715