Design of filter to reject motion artifact of pulse oximetry

被引:41
|
作者
Lee, J
Jung, W
Kang, I
Kim, Y
Lee, G
机构
[1] Gyeongsang Natl Univ, Dept Elect Engn, Bioelect Lab, Kyungnam 660701, Gyeongsangnamdo, South Korea
[2] YONAM Coll Engn, Dept Comp & Informat Technol, Jinju 660750, Kyungnam, South Korea
关键词
oxygen saturation; biomedical signal processing; motion artifact filter;
D O I
10.1016/s0920-5489(03)00077-1
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of the pulse oximeter, an instrument which non-invasively measures oxygen saturation in blood, is influenced by a patient's respiration or movement. Generally, the frequency band of the motion artifact signal generated from the patient's movement is overlapped with that of the patient's pulse wave which is measured by the received light sensor. Accordingly, it is difficult to filter the motion artifact of the pulse wave by using a filter which has a cut-off frequency that is fixed. In this study, the motion artifact is removed using the filter bank and the matched filter. Compared with traditional adaptive filter methods, the ratio variation is 50% lower than that of the moving average filter, allowing more stable measurement of oxygen saturation despite the patient's movement. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 50 条
  • [41] Pulse Oximetry
    Nasr, Viviane G.
    DiNardo, James A.
    PEDIATRICS IN REVIEW, 2019, 40 (11) : 605 - 608
  • [42] Pulse oximetry
    Jubran, A
    INTENSIVE CARE MEDICINE, 2004, 30 (11) : 2017 - 2020
  • [43] PULSE OXIMETRY
    ROLLY, G
    VERSICHELEN, L
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1989, 8 (03): : 171 - 174
  • [44] Pulse oximetry
    Amal Jubran
    Intensive Care Medicine, 2004, 30 : 2017 - 2020
  • [45] Comparison of Motion Artifact Response in Three Mobile Pulse Oximeters
    Petersen, Christian L.
    Gan, Heng
    Gorges, Matthias
    Ansermino, J. Mark
    Dumont, Guy A.
    ANESTHESIA AND ANALGESIA, 2014, 119
  • [46] Pulse oximetry
    Jubran, Amal
    CRITICAL CARE, 2015, 19
  • [47] Quantification of motion artifact in ECG electrode design
    Kearney, Kenneth
    Thomas, Chris
    McAdams, Eric
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1533 - +
  • [48] Pulse oximetry
    McMorrow, Roger C. N.
    Mythen, Michael G.
    CURRENT OPINION IN CRITICAL CARE, 2006, 12 (03) : 269 - 271
  • [49] Pulse Oximetry
    Avidan, Alexander
    Levin, Phillip D.
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (02): : 184 - 184
  • [50] PULSE OXIMETRY
    NEUFELD, GR
    MEDICAL INSTRUMENTATION, 1986, 20 (03): : 121 - 121