The Effect of Motion on Pulse Oximetry and Its Clinical Significance

被引:107
|
作者
Petterson, Michael T. [1 ]
Begnoche, Valerie L. [1 ]
Graybeal, John M. [1 ]
机构
[1] Masimo Corp, Irvine, CA 92618 USA
来源
ANESTHESIA AND ANALGESIA | 2007年 / 105卷
关键词
D O I
10.1213/01.ane.0000278134.47777.a5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Pulse oximetry is an important diagnostic and patient monitoring tool. However, motion can induce considerable error into pulse oximetry accuracy, resulting in loss of data, inaccurate readings, and false alarms. We will discuss how motion artifact affects pulse oximetry accuracy, the clinical consequences of motion artifact, and the methods used by various technologies to minimize the impact of the motion noise.
引用
收藏
页码:S78 / S84
页数:7
相关论文
共 50 条
  • [1] METHEMOGLOBINEMIA AND ITS EFFECT ON PULSE OXIMETRY
    DELWOOD, L
    OFLAHERTY, D
    PREJEAN, EJ
    GIESECKE, AH
    CRITICAL CARE MEDICINE, 1991, 19 (07) : 988 - 988
  • [2] Effect of limbs' motion on pulse oximetry in preterm infants
    Marchionni, Paolo
    Scalise, Lorenzo
    Palazzi, Maria Laura
    Ercoli, Ilaria
    Carnielli, Virgilio Paolo
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 505 - 510
  • [3] CLINICAL PULSE OXIMETRY
    SARNQUIST, FH
    LABORATORY MEDICINE, 1988, 19 (07) : 417 - 420
  • [4] Motion resistant pulse oximetry in neonates
    Sahni, R
    Gupta, A
    Ohira-Kist, K
    Rosen, TS
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2003, 88 (06): : F505 - F508
  • [5] Principles of pulse oximetry and its clinical application in neonatal medicine
    Tin, Win
    Lal, Mithilesh
    SEMINARS IN FETAL & NEONATAL MEDICINE, 2015, 20 (03): : 192 - 197
  • [6] Motion Artifact Mitigation for Wearable Pulse Oximetry
    Williamson, James R.
    Patel, Tejash
    Singh, Ninoshka
    Siegel, Andrew
    Telfer, Brian
    Trebicka, Ray
    Welsh, Brendon
    Hoyt, Reed
    2018 IEEE 15TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI) AND THE WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2018, : 74 - 77
  • [7] Pulse oximetry: Are health personnel aware of its clinical applications and limitations?
    Alshehri, M
    ANNALS OF SAUDI MEDICINE, 2000, 20 (01) : 75 - 77
  • [8] Fetal pulse oximetry: Clinical practice
    Vardon, D.
    Hors, Y.
    Grossetti, E.
    Creveuil, C.
    Herticoviez, M.
    Dreyfus, M.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2008, 37 (07): : 697 - 704
  • [9] Fetal pulse oximetry in clinical use
    Kühnert, M
    Seelbach-Göbel, B
    Butterwegge, M
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2001, 61 (05) : 290 - 296
  • [10] TEMPERATURE-DEPENDENCE OF LED AND ITS THEORETICAL EFFECT ON PULSE OXIMETRY
    REYNOLDS, KJ
    DEKOCK, JP
    TARASSENKO, L
    MOYLE, JTB
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (05) : 638 - 643