Design of filter to reject motion artifact of pulse oximetry

被引:41
|
作者
Lee, J
Jung, W
Kang, I
Kim, Y
Lee, G
机构
[1] Gyeongsang Natl Univ, Dept Elect Engn, Bioelect Lab, Kyungnam 660701, Gyeongsangnamdo, South Korea
[2] YONAM Coll Engn, Dept Comp & Informat Technol, Jinju 660750, Kyungnam, South Korea
关键词
oxygen saturation; biomedical signal processing; motion artifact filter;
D O I
10.1016/s0920-5489(03)00077-1
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of the pulse oximeter, an instrument which non-invasively measures oxygen saturation in blood, is influenced by a patient's respiration or movement. Generally, the frequency band of the motion artifact signal generated from the patient's movement is overlapped with that of the patient's pulse wave which is measured by the received light sensor. Accordingly, it is difficult to filter the motion artifact of the pulse wave by using a filter which has a cut-off frequency that is fixed. In this study, the motion artifact is removed using the filter bank and the matched filter. Compared with traditional adaptive filter methods, the ratio variation is 50% lower than that of the moving average filter, allowing more stable measurement of oxygen saturation despite the patient's movement. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 50 条
  • [1] COMPARATIVE AND EVALUATIVE THE ADAPTIVE FILTER IN MOTION ARTIFACT CANCELLATION OF PULSE OXIMETRY
    Kunchon, Sitthi
    Desudchit, Tayard
    Chinrungrueng, Chedsada
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 195 - +
  • [2] Motion Artifact Mitigation for Wearable Pulse Oximetry
    Williamson, James R.
    Patel, Tejash
    Singh, Ninoshka
    Siegel, Andrew
    Telfer, Brian
    Trebicka, Ray
    Welsh, Brendon
    Hoyt, Reed
    2018 IEEE 15TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI) AND THE WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2018, : 74 - 77
  • [3] Study On Resistance to Motion Artifact in Pulse Oximetry Measurement Using Segment Filter Method
    Li Qing-bo
    Nie Xin
    Zhang Guang-jun
    Wu Jin-guang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (11) : 2994 - 2997
  • [4] PULSE OXIMETRY AND MOTION ARTIFACT - A STUDY OF ACCURACY AND RELIABILITY
    BARKER, SJ
    SHAH, NK
    HYATT, J
    ANESTHESIOLOGY, 1995, 83 (3A) : A450 - A450
  • [5] AN UNUSUAL CAUSE OF MOTION ARTIFACT DURING PULSE OXIMETRY
    CONE, AM
    SANSOME, AJ
    ANAESTHESIA, 1992, 47 (10) : 917 - 917
  • [6] Investigating Motion Artifact in Reflective Pulse Oximetry During Random Motion
    Nawn, Corinne
    Warren, Kristen
    2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [7] Effects of Motion Artifact on the Blood Oxygen Saturation Estimate in Pulse Oximetry
    Clarke, Geoffrey W. J.
    Chan, Adrian D. C.
    Adler, Andy
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 275 - 278
  • [8] Comparative Evaluation of Adaptive Filters in Motion Artifact Cancellation for Pulse Oximetry
    Kunchon, Sitthi
    Desudchit, Tayard
    Chinrungrueng, Chedsada
    CSPA: 2009 5TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING AND ITS APPLICATIONS, PROCEEDINGS, 2009, : 307 - +
  • [9] A Pulse Oximetry System with Motion Artifact Reduction Based on Fourier Analysis
    Yang, Yi-Hsiang
    Tang, Kea-Tiong
    2014 IEEE INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2014,
  • [10] Methodology of generating motion artifact affects measures of pulse oximetry experimental performance
    Jopling, MW
    Bebout, DE
    Mannheimer, P
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A61 - A61