Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty

被引:6
|
作者
Sandberg, Olof [1 ]
Carlsson, Sofia [2 ]
Harbom, Ellen [3 ]
Cappelen, Vendela [3 ]
Tholen, Simon [2 ]
Olivecrona, Henrik [5 ]
Wretenberg, Per [4 ]
机构
[1] Sectra AB, Linkoping, Sweden
[2] Orebro Univ Hosp, Dept Radiol, Orebro, Sweden
[3] Orebro Univ, Sch Med Sci, Orebro, Sweden
[4] Orebro Univ Hosp, Dept Med Sci, Sect Orthopaed, Orebro, Sweden
[5] Karolinska Inst, Dept Mol Med & Surg, Solna, Sweden
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.2340/17453674.2022.5240
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Inducible displacement CT compares 2 CTs acquired in series but with alternated rota-tion of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. Patients and methods - This was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered. Results - Of 72 enrolled patients 15 were lost to follow-up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the cor-responding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine. Conclusion - Displacement CT with alternated rota-tions of the femur is a viable option to improve the diag-nostic process for identifying aseptic loosening in a total hip arthroplasty.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 50 条
  • [1] A review of aseptic loosening in total hip arthroplasty
    El-Warrak, AO
    Olmstead, ML
    von Rechenberg, B
    Auer, JA
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2001, 14 (03) : 115 - 124
  • [2] Diagnostic accuracy of bone turnover markers as a screening tool for aseptic loosening after total hip arthroplasty
    Lawrence, Neil R.
    Jayasuriya, Raveen L.
    Gossiel, Fatma
    Wilkinson, J. Mark
    HIP INTERNATIONAL, 2015, 25 (06) : 525 - 530
  • [3] The role of inducible nitric oxide synthase in aseptic loosening after total hip arthroplasty
    Suh, KT
    Chang, JW
    Jung, JS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05): : 753 - 757
  • [4] The role of hereditary hemochromatosis in aseptic loosening following primary total hip arthroplasty
    Lunn, JV
    Gallagher, PM
    Hegarty, S
    Kaliszer, M
    Crowe, J
    Murray, P
    Bouchier-Hayes, D
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (03) : 542 - 548
  • [5] No Association of CALCA Polymorphisms and Aseptic Loosening after Primary Total Hip Arthroplasty
    Aydin-Yuece, Tuenay
    Kurscheid, Gina
    Bachmann, Hagen Sjard
    Gehrke, Thorsten
    Dudda, Marcel
    Jaeger, Markus
    Wedemeyer, Christian
    Kauther, Max Daniel
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [6] Obesity Is Independently Associated With Early Aseptic Loosening in Primary Total Hip Arthroplasty
    Goodnough, Lawrence H.
    Finlay, Andrea K.
    Huddleston, James I., III
    Goodman, Stuart B.
    Maloney, William J.
    Amanatullah, Derek F.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 882 - 886
  • [7] Diagnostic accuracy of MRI with metal artifact reduction for the detection of periprosthetic joint infection and aseptic loosening of total hip arthroplasty
    Schwaiger, Benedikt J.
    Gassert, Florian T.
    Suren, Christian
    Gersing, Alexandra S.
    Haller, Bernhard
    Pfeiffer, Daniela
    Dangelmaier-Dawirs, Julia
    Roski, Ferdinand
    Von Eisenhart-Rothe, Rudiger
    Prodinger, Peter M.
    Woertler, Klaus
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [8] Aseptic Loosening of Total Hip Arthroplasty: Preliminary Genetic Investigation
    Godoy-Santos, Alexandre Leme
    D'Elia, Caio O.
    Teixeira, William J.
    Cabrita, Henrique B.
    Camanho, Gilberto L.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (02): : 297 - 302
  • [9] Correlation of Aspiration Results With Aseptic Loosening in Total Hip Arthroplasty
    Chalmers, Peter N.
    Sporer, Scott M.
    Levine, Brett R.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1671 - 1676
  • [10] Diagnosis and Detection of Subtle Aseptic Loosening in Total Hip Arthroplasty
    Anil, Utkarsh
    Singh, Vivek
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2022, 37 (08): : 1494 - 1500