Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty

被引:6
|
作者
Sandberg, Olof [1 ]
Carlsson, Sofia [2 ]
Harbom, Ellen [3 ]
Cappelen, Vendela [3 ]
Tholen, Simon [2 ]
Olivecrona, Henrik [5 ]
Wretenberg, Per [4 ]
机构
[1] Sectra AB, Linkoping, Sweden
[2] Orebro Univ Hosp, Dept Radiol, Orebro, Sweden
[3] Orebro Univ, Sch Med Sci, Orebro, Sweden
[4] Orebro Univ Hosp, Dept Med Sci, Sect Orthopaed, Orebro, Sweden
[5] Karolinska Inst, Dept Mol Med & Surg, Solna, Sweden
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.2340/17453674.2022.5240
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Inducible displacement CT compares 2 CTs acquired in series but with alternated rota-tion of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. Patients and methods - This was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered. Results - Of 72 enrolled patients 15 were lost to follow-up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the cor-responding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine. Conclusion - Displacement CT with alternated rota-tions of the femur is a viable option to improve the diag-nostic process for identifying aseptic loosening in a total hip arthroplasty.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 50 条
  • [21] Incidence of low-grade infection in aseptic loosening of total hip arthroplasty
    Moojen, Dirk Jan F.
    van Hellemondt, Gijs
    Vogely, H. Charles
    Burger, Bart J.
    Walenkamp, Geert H. I. M.
    Tulp, Niek J. A.
    Schreurs, B. Wim
    de Meulemeester, Frank R. A. J.
    Schot, Corrie S.
    van de Pol, Ingrid
    Fujishiro, Takaaki
    Schouls, Leo M.
    Bauer, Thomas W.
    Dhert, Wouter J. A.
    ACTA ORTHOPAEDICA, 2010, 81 (06) : 667 - 673
  • [22] REVISION TOTAL HIP ARTHROPLASTY IN PATIENTS WITH ASEPTIC LOOSENING OF FEMORAL STEM (REVIEW)
    Sementkovsky, A. V.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2011, (01): : 153 - 159
  • [23] Flow cytometry as a diagnostic tool for identifying total hip arthroplasty loosening and differentiating between septic and aseptic cases
    Ovrenovits M.
    Pakos E.E.
    Vartholomatos G.
    Paschos N.K.
    Xenakis T.A.
    Mitsionis G.I.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (7) : 1153 - 1159
  • [24] The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty
    Abrahams, J. M.
    Kim, Y. S.
    Callary, S. A.
    De Ieso, C.
    Costi, K.
    Howie, D. W.
    Solomon, L. B.
    BONE & JOINT JOURNAL, 2017, 99B (04): : 458 - 464
  • [25] High femoral offset as a risk factor for aseptic femoral component loosening in cementless primary total hip arthroplasty
    Lukas Jud
    Nico Rüedi
    Dimitris Dimitriou
    Armando Hoch
    Patrick O. Zingg
    International Orthopaedics, 2024, 48 : 1217 - 1224
  • [26] Revision for Aseptic Loosening of Highly Porous Acetabular Components in Primary Total Hip Arthroplasty: An Analysis of 20,993 Total Hip Replacements
    Hoskins, Wayne
    Rainbird, Sophia
    Holder, Carl
    Graves, Stephen E.
    Bingham, Roger
    JOURNAL OF ARTHROPLASTY, 2022, 37 (02): : 312 - 315
  • [27] High femoral offset as a risk factor for aseptic femoral component loosening in cementless primary total hip arthroplasty
    Jud, Lukas
    Ruedi, Nico
    Dimitriou, Dimitris
    Hoch, Armando
    Zingg, Patrick O.
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (05) : 1217 - 1224
  • [28] Diagnostic value of bone scintigraphy for aseptic loosening after total knee arthroplasty
    Claassen, Leif
    Ettinger, Max
    Plaass, Christian
    Daniilidis, Kiriakos
    Calliess, Tilman
    Ezechieli, Marco
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (05) : 767 - 773
  • [29] THE PROBLEM IN TOTAL JOINT ARTHROPLASTY - ASEPTIC LOOSENING
    GOLDRING, SR
    CLARK, CR
    WRIGHT, TM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06): : 799 - 801
  • [30] Revision total hip arthroplasty for aseptic loosening compared with primary total hip arthroplasty for osteoarthritis: long-term clinical, functional and quality of life outcome data
    Koutalos, Antonios A.
    Varitimidis, Sokratis
    Malizos, Konstantinos N.
    Karachaliosi, Theofilos
    HIP INTERNATIONAL, 2023, 33 (05) : 889 - 898