Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty

被引:6
|
作者
Sandberg, Olof [1 ]
Carlsson, Sofia [2 ]
Harbom, Ellen [3 ]
Cappelen, Vendela [3 ]
Tholen, Simon [2 ]
Olivecrona, Henrik [5 ]
Wretenberg, Per [4 ]
机构
[1] Sectra AB, Linkoping, Sweden
[2] Orebro Univ Hosp, Dept Radiol, Orebro, Sweden
[3] Orebro Univ, Sch Med Sci, Orebro, Sweden
[4] Orebro Univ Hosp, Dept Med Sci, Sect Orthopaed, Orebro, Sweden
[5] Karolinska Inst, Dept Mol Med & Surg, Solna, Sweden
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.2340/17453674.2022.5240
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Inducible displacement CT compares 2 CTs acquired in series but with alternated rota-tion of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. Patients and methods - This was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered. Results - Of 72 enrolled patients 15 were lost to follow-up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the cor-responding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine. Conclusion - Displacement CT with alternated rota-tions of the femur is a viable option to improve the diag-nostic process for identifying aseptic loosening in a total hip arthroplasty.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 50 条
  • [31] Granulocyte-macrophage colony stimulating factor in the aseptic loosening of total hip arthroplasty
    Xu, JW
    Konttinen, YT
    Waris, V
    GomezBarrena, E
    Sorsa, T
    Santavirta, S
    JOURNAL OF ORTHOPAEDIC RHEUMATOLOGY, 1996, 9 (03): : 128 - 134
  • [32] The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
    French, Timothy H.
    Russell, Nicholas
    Pillai, Anand
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [33] Bisphosphonates' use and risk of aseptic loosening following total hip arthroplasty: a systematic review
    Pegios, Vasileios F.
    Kenanidis, Eustathios
    Tsotsolis, Stavros
    Potoupnis, Michael
    Tsiridis, Eleftherios
    EFORT OPEN REVIEWS, 2023, 8 (11) : 798 - 808
  • [34] Local and Systemic Activation of the Mononuclear Phagocyte System in Aseptic Loosening of Total Hip Arthroplasty
    Flecher, Xavier
    Rolland, Christelle
    Rixrath, Emmanuel
    Argenson, Jean-Noel
    Robert, Philippe
    Bongrand, Pierre
    Wendling, Sylvie
    Vitte, Joana
    JOURNAL OF CLINICAL IMMUNOLOGY, 2009, 29 (05) : 681 - 690
  • [35] Local and Systemic Activation of the Mononuclear Phagocyte System in Aseptic Loosening of Total Hip Arthroplasty
    Xavier Flecher
    Christelle Rolland
    Emmanuel Rixrath
    Jean-Noel Argenson
    Philippe Robert
    Pierre Bongrand
    Sylvie Wendling
    Joana Vitte
    Journal of Clinical Immunology, 2009, 29 : 681 - 690
  • [36] Role of free radicals in aseptic loosening of hip arthroplasty
    Kinov, P
    Leithner, A
    Radl, R
    Bodo, K
    Khoschsorur, GA
    Schauenstein, K
    Windhager, R
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (01) : 55 - 62
  • [37] The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty
    Müller, U
    Gautier, E
    Roeder, C
    Busato, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (01): : 31 - 36
  • [38] Aseptic loosening of the humeral component in total shoulder arthroplasty
    Klimkiewicz, JJ
    Iannotti, JP
    Rubash, HE
    Shanbhag, AS
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (04) : 422 - 426
  • [39] Letter to the Editor: Aseptic Loosening of Total Hip Arthroplasty: Infection Always Should be Ruled Out
    Partridge, David G.
    Rambani, Reena
    Kerry, Robert M.
    Stockley, Ian
    Townsend, Robert
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (10) : 2971 - 2972
  • [40] circRNA expression pattern and ceRNA network in the pathogenesis of aseptic loosening after total hip arthroplasty
    Ni, Shenghui
    Jiang, Tianlong
    Hao, Shimin
    Luo, Peng
    Wang, Penghao
    Almatari, Yaser
    Wang, Yu
    Zhang, Zhiyu
    Guo, Lei
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2021, 18 (03): : 768 - 777