Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty

被引:6
|
作者
Sandberg, Olof [1 ]
Carlsson, Sofia [2 ]
Harbom, Ellen [3 ]
Cappelen, Vendela [3 ]
Tholen, Simon [2 ]
Olivecrona, Henrik [5 ]
Wretenberg, Per [4 ]
机构
[1] Sectra AB, Linkoping, Sweden
[2] Orebro Univ Hosp, Dept Radiol, Orebro, Sweden
[3] Orebro Univ, Sch Med Sci, Orebro, Sweden
[4] Orebro Univ Hosp, Dept Med Sci, Sect Orthopaed, Orebro, Sweden
[5] Karolinska Inst, Dept Mol Med & Surg, Solna, Sweden
关键词
COMPUTED-TOMOGRAPHY;
D O I
10.2340/17453674.2022.5240
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Inducible displacement CT compares 2 CTs acquired in series but with alternated rota-tion of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. Patients and methods - This was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered. Results - Of 72 enrolled patients 15 were lost to follow-up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the cor-responding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine. Conclusion - Displacement CT with alternated rota-tions of the femur is a viable option to improve the diag-nostic process for identifying aseptic loosening in a total hip arthroplasty.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 50 条
  • [41] Biochemical markers of bone turnover in aseptic loosening in hip arthroplasty
    Nikolaus A. Streich
    Tobias Gotterbarm
    Martin Jung
    Ulrich Schneider
    Christian Heisel
    International Orthopaedics, 2009, 33 : 77 - 82
  • [42] Immunohistochemical analysis of periprosthetic osteolysis in aseptic loosening of hip arthroplasty
    Gravius, S.
    Mumme, T.
    Delank, K. S.
    Eckardt, A.
    Maus, U.
    Andereya, S.
    Hansen, T.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 (02): : 169 - 175
  • [43] Association of NLRP3 and CARD8 Inflammasome Polymorphisms With Aseptic Loosening After Primary Total Hip Arthroplasty
    Mavcic, Blaz
    Antolic, Vane
    Dolzan, Vita
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (02) : 417 - 421
  • [44] Biochemical markers of bone turnover in aseptic loosening in hip arthroplasty
    Streich, Nikolaus A.
    Gotterbarm, Tobias
    Jung, Martin
    Schneider, Ulrich
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 77 - 82
  • [45] Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening
    Bao, Bo
    Liu, Crystal S.
    Masson, Edward C. O.
    Abele, Jonathan T.
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2021, 5 (01):
  • [46] Effect of cementing technique on aseptic stem loosening in cemented primary total hip arthroplasty: a systematic review and meta-analysis
    Hanif, Muhammad
    Arshad, Naveed
    Habib, Yasir
    Shami, Ali Miraj
    Rehman, Obaid Ur
    Rehman, Muhammad
    Reyaz, Muddasir
    Mumtaz, Hassan
    ANNALS OF MEDICINE AND SURGERY, 2023, 85 (06): : 2884 - 2895
  • [47] EARLY ASEPTIC LOOSENING OF UNCEMENTED FEMORAL COMPONENTS IN PRIMARY TOTAL HIP-REPLACEMENT - A REVIEW BASED ON THE NORWEGIAN ARTHROPLASTY REGISTER
    HAVELIN, LI
    ESPEHAUG, B
    VOLLSET, SE
    ENGESAETER, LB
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (01): : 11 - 17
  • [48] Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening
    Bo Bao
    Crystal S. Liu
    Edward C. O. Masson
    Jonathan T. Abele
    European Journal of Hybrid Imaging, 5
  • [49] Aspirin Thromboprophylaxis Confers No Increased Risk for Aseptic Loosening Following Cementless Primary Hip Arthroplasty
    Goswami, Karan
    Tan, Timothy L.
    Rondon, Alexander J.
    Shohat, Noam
    Yayac, Michael
    Schlitt, Patrick K.
    Courtney, P. Maxwell
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12): : 2978 - 2982
  • [50] Accuracy of intraoperative cultures in primary total hip arthroplasty
    Picado, C. H. F.
    Garcia, F. L.
    Chagas, M. V., Jr.
    Toquetao, F. G.
    HIP INTERNATIONAL, 2008, 18 (01) : 46 - 50