Diagnostic accuracy of bone turnover markers as a screening tool for aseptic loosening after total hip arthroplasty

被引:9
|
作者
Lawrence, Neil R. [1 ]
Jayasuriya, Raveen L. [1 ]
Gossiel, Fatma [1 ]
Wilkinson, J. Mark [1 ]
机构
[1] Univ Sheffield, Sheffield S10 2RX, S Yorkshire, England
关键词
Aseptic loosening; ICTP; dkk-1; TRAP5b; Biochemical markers; Bone turnover; BIOCHEMICAL MARKERS; TERMINAL TELOPEPTIDE; MINERAL DENSITY; REPLACEMENT; ICTP; OSTEOPOROSIS; METABOLISM; COMPONENT; DISEASE; CANCER;
D O I
10.5301/hipint.5000253
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aseptic loosening is the most common cause of prosthesis failure after total hip arthroplasty (THA). We measured serum cross-linked carboxyterminal telopeptide of type I collagen (ICTP), tartrate-resistant acid phosphatase 5b (TRAP5b), dickkopf-1 (dkk-1) and sclerostin; and urinary a isomer of C-terminal cross-linked telopeptide of type I collagen (alpha CTX-I) to investigate their potential diagnostic value detecting aseptic loosening after THA. Biomarkers were measured in 24 subjects with aseptic loosening of THA versus 26 control subjects without loosening after THA. Serum ICTP in the loose group (7.04 ng/mL) was higher than controls (5.15 ng/mL), (p = 0.0007). ROC analysis demonstrated that a serum ICTP >5.5 ng/L had a sensitivity of 91% and specificity of 69% for detecting aseptic loosening (area under ROC curve = 0.77, p = 0.0001), resulting in a positive predictive value (PPV) of 73% and a negative predictive value (NPV) of 90%. Serum TRAP5b in the aseptic loosening group (4.17U/L) was higher than controls (3.44 U/L), (p = 0.03). A serum TRAP5b >2.46 U/L had sensitivity of 100% and a specificity of 31% to detect aseptic loosening (AUC 0.67, p = 0.031), resulting in a PPV of 57% and a NPV of 100%. Serum dkk-1, serum sclerostin and urinary aCTX-I were not elevated in subjects with aseptic loosening (p>0.05). Serum ICTP and TRAP5b show potential utility as screening biomarkers for excluding aseptic loosening, because of their ability to discriminate individuals without disease. Our finding of elevated ICTP, generated by the action of matrix metalloproteinases, suggests a role for this group of endopeptidases in aseptic loosening.
引用
收藏
页码:525 / 530
页数:6
相关论文
共 50 条
  • [1] Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty
    Wilkinson, JM
    Hamer, AJ
    Stockley, I
    Eastell, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (07) : 1337 - 1337
  • [2] Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty
    Wilkinson, JM
    Hamer, AJ
    Rogers, A
    Stockley, I
    Eastell, R
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (04) : 691 - 696
  • [3] Biochemical markers of bone turnover in aseptic loosening in hip arthroplasty
    Nikolaus A. Streich
    Tobias Gotterbarm
    Martin Jung
    Ulrich Schneider
    Christian Heisel
    International Orthopaedics, 2009, 33 : 77 - 82
  • [4] Biochemical markers of bone turnover in aseptic loosening in hip arthroplasty
    Streich, Nikolaus A.
    Gotterbarm, Tobias
    Jung, Martin
    Schneider, Ulrich
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 77 - 82
  • [5] Diagnostic value of bone scintigraphy for aseptic loosening after total knee arthroplasty
    Claassen, Leif
    Ettinger, Max
    Plaass, Christian
    Daniilidis, Kiriakos
    Calliess, Tilman
    Ezechieli, Marco
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (05) : 767 - 773
  • [6] Inducible displacement CT increases the diagnostic accuracy of aseptic loosening in primary total hip arthroplasty
    Sandberg, Olof
    Carlsson, Sofia
    Harbom, Ellen
    Cappelen, Vendela
    Tholen, Simon
    Olivecrona, Henrik
    Wretenberg, Per
    ACTA ORTHOPAEDICA, 2022, 93 : 831 - 836
  • [7] A review of aseptic loosening in total hip arthroplasty
    El-Warrak, AO
    Olmstead, ML
    von Rechenberg, B
    Auer, JA
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2001, 14 (03) : 115 - 124
  • [8] Aseptic Loosening after total hip arthroplasty secondary to the disappearing coating?
    Tang, Kaiying
    Deng, Zhibo
    Wang, Ting
    Nie, Mao
    ASIAN JOURNAL OF SURGERY, 2022, 45 (01) : 535 - 536
  • [9] Flow cytometry as a diagnostic tool for identifying total hip arthroplasty loosening and differentiating between septic and aseptic cases
    Ovrenovits M.
    Pakos E.E.
    Vartholomatos G.
    Paschos N.K.
    Xenakis T.A.
    Mitsionis G.I.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (7) : 1153 - 1159
  • [10] No Association of CALCA Polymorphisms and Aseptic Loosening after Primary Total Hip Arthroplasty
    Aydin-Yuece, Tuenay
    Kurscheid, Gina
    Bachmann, Hagen Sjard
    Gehrke, Thorsten
    Dudda, Marcel
    Jaeger, Markus
    Wedemeyer, Christian
    Kauther, Max Daniel
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018