Ion recombination corrections of ionization chambers in flattening filter-free photon radiation

被引:29
|
作者
Wang, Yuenan [1 ]
Easterling, Stephen B. [1 ]
Ting, Joseph Y. [1 ]
机构
[1] Melbourne Canc Ctr, Melbourne, FL 32901 USA
来源
关键词
flattening filter free; ion recombination; two-voltage technique; P-ion; ionization chamber; MODULATED ARC THERAPY; STEREOTACTIC RADIOTHERAPY; REFERENCE DOSIMETRY; ELECTRON-BEAMS; ACCELERATOR;
D O I
10.1120/jacmp.v13i5.3758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The flattening filter free (FFF) X-rays can provide much higher dose rate at the treatment target compared to the conventional flattened X-rays. However, the substantial increase of dose rate for FFF beams may affect the ion recombination correction factor, which is required for accurate measurements using ionization chambers in clinical dosimetry. The purpose of this work is to investigate the ion recombination of three types of commonly used ion chambers (Farmer, PinPoint and plane-parallel) in the FFF photon radiation. Both 6 MV and 10 MV flattened and FFF beams were fully commissioned on a Varian TrueBeam linear accelerator. The ion recombination correction factor, P-ion, was determined using the two-voltage technique for a 0.6 cc Farmer chamber, a 0.015 cc PinPoint chamber, and a 0.02 cc parallel-plate chamber at different source-to-axis distances (SAD) in a solid water phantom or water tank phantom at a depth of 10 cm in a 10 x 10 cm(2) field. Good repeatability of measurements was demonstrated. Less than 1% difference in Pion between the flattened and FFF photons for all three ion chambers was observed. At a SAD of 100 cm and a depth of 10 cm for a 10 x 10 cm(2) field, P-ion for the Farmer chamber was 1.004 and 1.008 for the 6 MV flattened and FFF beams, respectively. At the same setup using the Farmer chamber, P-ion was 1.002 and 1.015 for the 10 MV flattened and FFF beams, respectively. All P-ion results for the Farmer, PinPoint, or parallel plate chamber in the 6 MV and 10 MV flattened and FFF beams were within 2% from the unity (1 <= P-ion < 1.02). The Pion ratio of the FFF to flattened beams was 0.99 similar to 1.01 for both 6 MV and 10 MV photons. The ion recombination effect of the Farmer, PinPoint, and plane-parallel chamber in the FFF beams is not substantially different from that in the conventional flattened beams.
引用
下载
收藏
页码:262 / 268
页数:7
相关论文
共 50 条
  • [21] Monte Carlo study of photon fields from a flattening filter-free clinical accelerator
    Vassiliev, ON
    Titt, U
    Kry, SF
    Pönisch, F
    Gillin, MT
    Mohan, R
    MEDICAL PHYSICS, 2006, 33 (04) : 820 - 827
  • [22] DNA strand breaks based on Monte Carlo simulation in and around the Lipiodol with flattening filter and flattening filter-free photon beams
    Kawahara, Daisuke
    Saito, Akito
    Nakano, Hisashi
    Nagata, Yasushi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (03) : 392 - 400
  • [23] Charge recombination correction for flattening filter free radiation beam
    Chehrazi, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1090 - 1090
  • [24] Dosimetric impact of flattening filter and flattening filter-free beams on IMRT planning of NSCLC
    Lee, S. W. Y.
    Or, K. M. K.
    Kwong, Y. P. J.
    Choy, Y. H. S.
    Kwong, C. Y. K.
    Keung, H. K.
    Wu, V. W. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S485 - S486
  • [25] Influence of the Applied Voltage On the Ion Recombination Correction Factor Using the Two-Voltage Technique in Flattening Filter-Free Beams
    Yada, R.
    Hayashi, N.
    Akasaka, H.
    Mukumoto, N.
    Sasaki, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 3220 - 3220
  • [26] Flattening Filter-free Beams for SBRT: Advantages and Risks
    Verbakel, W.
    Ong, C.
    Senan, S.
    Cuijpers, J. P.
    Slotman, B. J.
    Dahele, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S826 - S827
  • [27] Feasibility of portal dosimetry for flattening filter-free radiotherapy
    Chuter, Robert W.
    Rixham, Philip A.
    Weston, Steve J.
    Cosgrove, Vivian P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 112 - 120
  • [28] Dosimetry of a 6 MV flattening filter-free small photon beam using various detectors
    Dwivedi, Shekhar
    Kansal, Sandeep
    Dangwal, Vinod Kumar
    Bharati, Avinav
    Shukla, Jooli
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04):
  • [29] Ion recombination in parallel-plate free-air ionization chambers for synchrotron radiation
    Nariyama, Nobuteru
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : 5199 - 5209
  • [30] Impact of Flattening Filter-Free (FFF) Radiation on the Clonogenic Survival of Astrocytoma Cell Lines
    Giordano, F. A.
    Steenken, C.
    Fleckenstein, J.
    Jahnke, L.
    Kegel, S.
    Hartmann, L.
    Kuebler, J.
    Wenz, F.
    Herskind, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S778 - S778