Dosimetry of a 6 MV flattening filter-free small photon beam using various detectors

被引:4
|
作者
Dwivedi, Shekhar [1 ,2 ,3 ]
Kansal, Sandeep [3 ]
Dangwal, Vinod Kumar [4 ]
Bharati, Avinav [5 ]
Shukla, Jooli [6 ]
机构
[1] Homi Bhabha Canc Hosp & Res Ctr, Dept Med Phys, Tata Mem Ctr, Mullanpur, India
[2] Homi Bhabha Canc Hosp & Res Ctr, Dept Med Phys, Tata Mem Ctr, Sangrur, India
[3] Ranjit Singh Punjab Tech Univ, Dept Phys, Bathinda, India
[4] Govt Med Coll, Dept Radiotherapy, Patiala, Punjab, India
[5] Dr Ram Manohar Lohia Inst Med Sci, Dept Radiat Oncol, Lucknow, Uttar Pradesh, India
[6] Dr Bhimrao Ambedkar Univ, Dept Phys, Agra, Uttar Pradesh, India
关键词
small-field dosimetry; FFF photon beam; detector; output factor; MONTE-CARLO; SMALL FIELDS; MULTILEAF COLLIMATOR; PROFILE MEASUREMENTS; RADIOCHROMIC FILM; QUALITY-ASSURANCE; BUILDUP REGION; ENERGY; DIODE; SIZE;
D O I
10.1088/2057-1976/abfd80
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present study aimed to dosimetrically evaluate the small-fields of a 6 MV flattening filter-free (FFF) photon beam using different detectors.The 6 MV FFF photon beam was used for measurement of output factor, depth dose, and beam profile of small-fields of sizes 0.6 cm x 0.6 cm to 6.0 cm x 6.0 cm. The five detectors used were SNC125c, PinPoint, EDGE, EBT3, and TLD-100. All measurements were performed as per the International Atomic Energy Agency TRS 483 protocol. Output factors measured using different detectors as direct reading ratios showed significant variation for the smallest fields, whereas after correcting them according to TRS 483, all sets of output factors were nearly compatible with each other when measurement uncertainty was also considered. The beam profile measured using SNC125c showed the largest penumbra for all field sizes, whereas the smallest was recorded with EDGE. Compared with that of EBT3, the surface dose was found to be much higher for all the other detectors. PinPoint, EBT3, TLD-100, and EDGE were found to be the detector of choice for small-field output factor measurements; however, PinPoint needs special attention when used for the smallest field size (0.6 cm x 0.6 cm). EDGE and EBT3 are optimal for measuring beam profiles. EBT3, PinPoint, and EDGE can be selected for depth dose measurements, and EBT3 is suitable for surface dose estimation.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Small-field Dosimetry of 6-and 10-MV Flattening Filter-free and Flattening Filter Photon Beams for Therapeutic Use
    Shukla, Jooli
    Dwivedi, Shekhar
    Kansal, Sandeep
    Dangwal, Vinod Kumar
    Tiwari, K. P.
    Singla, Amit Kumar
    Rani, Supriya
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2023, 61 (10) : 846 - 850
  • [2] Monte Carlo study of a flattening filter-free 6 MV photon beam using the BEAMnrc code.
    Kajaria, Ankit
    Sharma, Neeraj
    Sharma, Shiru
    Pradhan, Satyajit
    Mandal, Abhijit
    Aggarwal M, Lalit
    [J]. BIOMEDICAL RESEARCH-INDIA, 2017, 28 (04): : 1566 - 1573
  • [3] Determination of small field output factors in 6 and 10 MV flattening filter free photon beams using various detectors
    Masanga, W.
    Tangboonduangjit, P.
    Khamfongkhruea, C.
    Tannanonta, C.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Dosimetric properties of a flattening filter-free 6-MV photon beam: A Monte Carlo study
    Mesbahi A.
    Mehnati P.
    Keshtkar A.
    Farajollahi A.
    [J]. Radiation Medicine, 2007, 25 (7): : 315 - 324
  • [5] Evaluation of dosimetric parameters of small fields of 6 MV flattening filter free photon beam measured using various detectors against Monte Carlo simulation
    Mamballikalam, Gopinath
    Senthilkumar, S.
    Jayadevan, P. M.
    Jaon Bos, R. C.
    Ahamed Basith, P. M.
    Inippully, Rohit
    Shine, N. S.
    Clinto, C. O.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 332 - 339
  • [6] Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam
    Diego Azcona, Juan
    Barbes, Benigno
    Moran, Veronica
    Burguete, Javier
    [J]. MEDICAL DOSIMETRY, 2017, 42 (04) : 282 - 288
  • [7] Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study
    Martinez-Rovira, Immaculada
    Puxeu-Vaque, Josep
    Prezado, Yolanda
    [J]. MEDICAL PHYSICS, 2017, 44 (10) : 5378 - 5383
  • [8] Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code
    Sangeetha, S.
    Sureka, C. S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 63 - 75
  • [9] Commissioning of portal dosimetry using a novel method for flattening filter-free photon beam in a nontrue beam linear accelerator
    Gandhi, Arun
    Vellaiyan, Subramani
    Subramanian, V. S.
    Shanmugam, Thirumalaiswamy
    Murugesan, Kathirvel
    Subramanian, Kala
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (01) : 223 - 230
  • [10] On flattening filter-free portal dosimetry
    Pardo, Eduardo
    Castro Novais, Juan
    Molina Lopez, Maria Yolanda
    Ruiz Maqueda, Sheila
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 132 - 145