Accurate assessment of mitral valve area in patients with mitral stenosis by three-dimensional echocardiography

被引:55
|
作者
Chen, QW
Nosir, YFM
Vletter, WB
Kint, PP
Salustri, A
Roelandt, JRTC
机构
[1] UNIV ROTTERDAM HOSP,DIV CARDIOL,THORAXCTR,NL-3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,NL-3000 DR ROTTERDAM,NETHERLANDS
[3] DIJKZIGT UNIV,ROTTERDAM,NETHERLANDS
关键词
D O I
10.1016/S0894-7317(97)70085-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of measurements of mitral valve orifice area (MVA) from three-dimensional; echocardiographic (3DE) image data sets obtained by a transthoracic or transesophageal rotational imaging probe was studied in 15 patients with native mitral stenosis. The smallest MVA was identified from a set of eight parallel short-axis cut planes of the mitral valve between the anulus and the tips of leaflets (paraplane echocardiography) and measured by planimetry. In addition, MVA was measured from the two-dimensional short-axis view (2DE). Values of MVA measured by 3DE and 2DE were compared with those calculated from Doppler pressure half-time (PHT) as a gold standard. Observer variabilities were studied for 3DE. MVA measured from PHT ranged between 0.55 and 3.19 cm(2) (mean +/- SD 1.57 +/- 0.73 cm(2)), from 3DE between 0.83 and 3.23 cm(2) (mean +/- SD 1.55 +/- 0.67 cm(2)), and from 2DE between 1.27 and 4.08 cm(2) (mean +/- SD 1.9 +/- 0.7 cm(2)). The variability of intraobserver and interobserver measurements for 3DE measurements was not significantly different (p = 0.79 and p = 0.68, respectively); for interobserver variability, standard error of the estimate = 0.25. There was excellent correlation, close limits of agreement (mean difference +/- 2SD), and nonsignificant differences between 3DE and PHT for MVA measurements (r = 0.98 [0.02 +/- 0.3] and p = 0.6), respectively. There was moderate correlation, wider limits of agreement, and significant difference between 2DE and PHT for MVA measurements (r = 0.89 [0.32 +/- 0.66] and p = 0.002), respectively. This may be related to the difficulties in visualization of the smallest orifice in precordial short-axis views. This study suggests that three-dimensional image data sets, by providing the possibility of ''computer slicing'' to generate equidistant parallel cross sections of the mitral valve independently from physically dictated ultrasonic windows, allow accurate and reproducible measurement of the MVA.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [21] Three-dimensional Echocardiography in Mitral Valve Disease
    Kamp, Otto
    Valocik, Gabriel
    EUROPEAN CARDIOLOGY REVIEW, 2005,
  • [22] Three-dimensional echocardiography and mitral valve disease
    Chapman C.B.
    Rahko P.S.
    Current Cardiology Reports, 2010, 12 (3) : 243 - 249
  • [23] Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography
    Binder, TM
    Rosenhek, R
    Porenta, G
    Maurer, G
    Baumgartner, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1355 - 1361
  • [24] Three-dimensional evaluation of the mitral valve area and commissural opening before and after percutaneous mitral commissurotomy in patients with mitral stenosis
    Messika-Zeitoun, David
    Brochet, Eric
    Holmin, Caroline
    Rosenbaum, David
    Cormier, Bertrand
    Serfaty, Jean-Michel
    Iung, Bernard
    Vahanian, Alec
    EUROPEAN HEART JOURNAL, 2007, 28 (01) : 72 - 79
  • [25] Three-dimensional evaluation of the mitral valve area and commissural opening before and after percutaneous mitral commissurotomy in patients with mitral stenosis
    Messika-Zeitoun, D.
    Brochet, E.
    Rosenbaum, D.
    Cormier, B.
    Serfati, J. M.
    Lung, B.
    Vahanian, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 900 - 900
  • [26] Impact of Net Atrioventricular Compliance on Mitral Valve Area Assessment-A Perspective Considering Three-Dimensional Mitral Valve Area by Transesophageal Echocardiography
    Li, Tony
    Leow, Ryan
    Chan, Meei Wah
    Kong, William K. F.
    Kuntjoro, Ivandito
    Poh, Kian Keong
    Sia, Ching Hui
    Yeo, Tiong Cheng
    DIAGNOSTICS, 2024, 14 (15)
  • [27] Application of three-dimensional echocardiography in patients with mitral valve repair
    Hong, Tao
    Song, Kai
    Wang, Chun-Sheng
    Wang, Min-Sheng
    Zhao, Qiang
    Fudan University Journal of Medical Sciences, 2004, 31 (01): : 12 - 14
  • [28] Discrepancy between mitral valve areas measured by two-dimensional planimetry and three-dimensional transoesophageal echocardiography in patients with mitral stenosis
    Min, Sun-Yang
    Song, Jong-Min
    Kim, Yun-Jeong
    Park, Hong-Kyung
    Seo, Mi-Ohk
    Lee, Moo-Song
    Kim, Dae-Hee
    Kang, Duk-Hyun
    Song, Jae-Kwan
    HEART, 2013, 99 (04) : 253 - 258
  • [29] COMPARATIVE EVALUATION OF MITRAL LEAFLET AREA IN MITRAL VALVE PROLAPSE AND FUNCTIONAL MITRAL REGURGITATION BY THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Maruo, Takeshi
    Komiya, Tatsuhiko
    Yamamoto, Hiroyuki
    Fuku, Yasushi
    Kadota, Kazushige
    Mitsudo, Kazuaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E851 - E851
  • [30] MEASUREMENT OF THREE-DIMENSIONAL (3D) MITRAL VALVE AREA IN PATIENTS WITH MITRAL ANNULAR CALCIFICATION BY TRANSTHORACIC ECHOCARDIOGRAPHY
    Gupta, Aashish
    Okor, Ivana
    Kachur, Sergey
    Kadakia, Rikin
    Stone, Michael
    Morris, Jessica
    Morin, Daniel
    Gilliland, Yvonne
    Pressman, Gregg
    Qamruddin, Salima
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1348 - 1348