Accurate assessment of mitral valve area in patients with mitral stenosis by three-dimensional echocardiography

被引:55
|
作者
Chen, QW
Nosir, YFM
Vletter, WB
Kint, PP
Salustri, A
Roelandt, JRTC
机构
[1] UNIV ROTTERDAM HOSP,DIV CARDIOL,THORAXCTR,NL-3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,NL-3000 DR ROTTERDAM,NETHERLANDS
[3] DIJKZIGT UNIV,ROTTERDAM,NETHERLANDS
关键词
D O I
10.1016/S0894-7317(97)70085-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of measurements of mitral valve orifice area (MVA) from three-dimensional; echocardiographic (3DE) image data sets obtained by a transthoracic or transesophageal rotational imaging probe was studied in 15 patients with native mitral stenosis. The smallest MVA was identified from a set of eight parallel short-axis cut planes of the mitral valve between the anulus and the tips of leaflets (paraplane echocardiography) and measured by planimetry. In addition, MVA was measured from the two-dimensional short-axis view (2DE). Values of MVA measured by 3DE and 2DE were compared with those calculated from Doppler pressure half-time (PHT) as a gold standard. Observer variabilities were studied for 3DE. MVA measured from PHT ranged between 0.55 and 3.19 cm(2) (mean +/- SD 1.57 +/- 0.73 cm(2)), from 3DE between 0.83 and 3.23 cm(2) (mean +/- SD 1.55 +/- 0.67 cm(2)), and from 2DE between 1.27 and 4.08 cm(2) (mean +/- SD 1.9 +/- 0.7 cm(2)). The variability of intraobserver and interobserver measurements for 3DE measurements was not significantly different (p = 0.79 and p = 0.68, respectively); for interobserver variability, standard error of the estimate = 0.25. There was excellent correlation, close limits of agreement (mean difference +/- 2SD), and nonsignificant differences between 3DE and PHT for MVA measurements (r = 0.98 [0.02 +/- 0.3] and p = 0.6), respectively. There was moderate correlation, wider limits of agreement, and significant difference between 2DE and PHT for MVA measurements (r = 0.89 [0.32 +/- 0.66] and p = 0.002), respectively. This may be related to the difficulties in visualization of the smallest orifice in precordial short-axis views. This study suggests that three-dimensional image data sets, by providing the possibility of ''computer slicing'' to generate equidistant parallel cross sections of the mitral valve independently from physically dictated ultrasonic windows, allow accurate and reproducible measurement of the MVA.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [41] Three-dimensional echocardiography to quantify mitral valve regurgitation
    Little, Stephen H.
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (05) : 477 - 484
  • [42] Three-Dimensional Echocardiography of the Mitral Valve: Lessons Learned
    Francesco Maffessanti
    Oana Mirea
    Gloria Tamborini
    Mauro Pepi
    Current Cardiology Reports, 2013, 15
  • [43] Three-Dimensional Echocardiography of the Mitral Valve: Lessons Learned
    Maffessanti, Francesco
    Mirea, Oana
    Tamborini, Gloria
    Pepi, Mauro
    CURRENT CARDIOLOGY REPORTS, 2013, 15 (07)
  • [44] Modeling the Myxomatous Mitral Valve With Three-Dimensional Echocardiography
    Pouch, Alison M.
    Jackson, Benjamin M.
    Lai, Eric
    Takebe, Manabu
    Tian, Sijie
    Cheung, Albert T.
    Woo, Y. Joseph
    Patel, Prakash A.
    Wang, Hongzhi
    Yushkevich, Paul A.
    Gorman, Robert C.
    Gorman, Joseph H., III
    ANNALS OF THORACIC SURGERY, 2016, 102 (03): : 703 - 711
  • [45] Mitral Annular Morphology in Mitral Valve Disease with Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kawai, Junichi
    Kitai, Takeshi
    Kim, Kitae
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 193 - 199
  • [46] Study of mitral valve remodling in patients with atrial functional mitral valve regurgitation using three-dimensional echocardiography
    Khedr, Kawkab
    Elsharkawy, Eman
    Shehata, Hoda
    Mowafy, Bassant
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : F6 - F6
  • [47] QUANTIFICATION OF MITRAL-VALVE AREA IN MITRAL-STENOSIS BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - DESCRIPTION OF A SIMPLIFIED AND ACCURATE METHOD
    QUINONES, MA
    FARMER, KL
    NELSON, JG
    WINTERS, WL
    WAGGONER, AD
    MILLER, RR
    CLINICAL RESEARCH, 1980, 28 (02): : A201 - A201
  • [48] Additional value of three-dimensional transesophageal echocardiography for patients with mitral valve stenosis undergoing balloon valvuloplasty
    Langerveld, J
    Valocik, G
    Plokker, HWT
    Ernst, SMPG
    Mannaerts, HFJ
    Kelder, JC
    Kamp, O
    Jaarsma, W
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (08) : 841 - 849
  • [49] Utility of three-dimensional echocardiography for assessment of double-orifice mitral valve
    Bhattacharyya, Sanjeev
    West, Cathy
    Chinasamy, Dev
    Senior, Roxy
    Li, Wei
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (08) : 672 - 672
  • [50] Quantitative Assessment of Mitral Valve Coaptation Using Three-Dimensional Transesophageal Echocardiography
    Cobey, Frederick C.
    Swaminathan, Madhav
    Phillips-Bute, Barbara
    Hyca, Martin
    Glower, Donald D.
    Douglas, Pamela S.
    Shaw, Andrew D.
    Mathew, Joseph P.
    Mackensen, G. Burkhard
    ANNALS OF THORACIC SURGERY, 2014, 97 (06): : 1998 - 2004