摘要
The accuracy of measurements of mitral valve orifice area (MVA) from three-dimensional; echocardiographic (3DE) image data sets obtained by a transthoracic or transesophageal rotational imaging probe was studied in 15 patients with native mitral stenosis. The smallest MVA was identified from a set of eight parallel short-axis cut planes of the mitral valve between the anulus and the tips of leaflets (paraplane echocardiography) and measured by planimetry. In addition, MVA was measured from the two-dimensional short-axis view (2DE). Values of MVA measured by 3DE and 2DE were compared with those calculated from Doppler pressure half-time (PHT) as a gold standard. Observer variabilities were studied for 3DE. MVA measured from PHT ranged between 0.55 and 3.19 cm(2) (mean +/- SD 1.57 +/- 0.73 cm(2)), from 3DE between 0.83 and 3.23 cm(2) (mean +/- SD 1.55 +/- 0.67 cm(2)), and from 2DE between 1.27 and 4.08 cm(2) (mean +/- SD 1.9 +/- 0.7 cm(2)). The variability of intraobserver and interobserver measurements for 3DE measurements was not significantly different (p = 0.79 and p = 0.68, respectively); for interobserver variability, standard error of the estimate = 0.25. There was excellent correlation, close limits of agreement (mean difference +/- 2SD), and nonsignificant differences between 3DE and PHT for MVA measurements (r = 0.98 [0.02 +/- 0.3] and p = 0.6), respectively. There was moderate correlation, wider limits of agreement, and significant difference between 2DE and PHT for MVA measurements (r = 0.89 [0.32 +/- 0.66] and p = 0.002), respectively. This may be related to the difficulties in visualization of the smallest orifice in precordial short-axis views. This study suggests that three-dimensional image data sets, by providing the possibility of ''computer slicing'' to generate equidistant parallel cross sections of the mitral valve independently from physically dictated ultrasonic windows, allow accurate and reproducible measurement of the MVA.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [31] Three-dimensional transesophageal echocardiography measurement of mitral valve area in patients with rheumatic mitral stenosis: multiplanar reconstruction or 3D direct planimetry?
    Zhong, Xinbo
    Chen, Wenbin
    Shi, Zhiyong
    Huan, Zhifu
    Ma, Lanxiang
    Liu, Wei
    Yang, Xiaohan
    Xu, Yan
    Jiang, Yong
    Lee, Alex Pui-Wai
    Guo, Ruiqiang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (01): : 99 - 107
  • [32] Three-dimensional transesophageal echocardiography measurement of mitral valve area in patients with rheumatic mitral stenosis: multiplanar reconstruction or 3D direct planimetry?
    Xinbo Zhong
    Wenbin Chen
    Zhiyong Shi
    Zhifu Huan
    Lanxiang Ma
    Wei Liu
    Xiaohan Yang
    Yan Xu
    Yong Jiang
    Alex Pui-Wai Lee
    Ruiqiang Guo
    The International Journal of Cardiovascular Imaging, 2021, 37 : 99 - 107
  • [33] Three dimensional echocardiography for the assessment of mitral valve disease
    Sutaria, N
    Northridge, D
    Masani, N
    Pandian, N
    HEART, 2000, 84 : 7 - 10
  • [34] Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation -: An accurate and novel approach
    Zamorano, J
    Cordeiro, P
    Sugeng, L
    de Isla, LP
    Weinert, L
    Macaya, C
    Rodríguez, E
    Lang, RM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) : 2091 - 2096
  • [35] Assessing mitral valve area and orifice geometry in calcific mitral stenosis: A new solution by real-time three-dimensional echocardiography
    Chu, John W.
    Levine, Robert A.
    Chua, Sarah
    Poh, Kian-Keong
    Morris, Eleanor
    Hua, Lanqi
    Ton-Nu, Thanh-Thao
    Hung, Judy
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (09) : 1006 - 1009
  • [36] Determination of Inoue Balloon Size by Analysis of Mitral Valve Geometry Using Three-Dimensional Transesophageal Echocardiography in Patients With Mitral Stenosis
    Kim, Mi-Jin
    Jung, Yoo-Jin
    Lee, Sun-Hack
    Sun, Byung Joo
    Lee, Sahmin
    Ahn, Jung-Min
    Park, Duk-Woo
    Kim, Dae-Hee
    Kang, Duk-Hyun
    Song, Jong-Min
    AMERICAN JOURNAL OF CARDIOLOGY, 2025, 235 : 51 - 58
  • [37] Three-dimensional echocardiography in congenital malformations of the mitral valve
    Espinola-Zavaleta, N
    Vargas-Barrón, J
    Keirns, C
    Rivera, G
    Romero-Cárdenas, A
    Roldán, J
    Attie, F
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (05) : 468 - 472
  • [38] Three-dimensional echocardiography in the management of parachute mitral valve
    Valverde, Israel
    Rawlins, Debbie
    Austin, Conal
    Simpson, John M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (05) : 446 - 446
  • [39] Three-dimensional reconstruction of mitral valve by transesophageal echocardiography
    Elmaghraby, Ahmed Mohamed
    Salustri, Alessandro
    HEART VIEWS, 2019, 20 (04): : 178 - 179
  • [40] Assessment of the mitral valve area in patients with mitral stenosis by computed tomography
    Messika-Zeitoun, D.
    Serfati, J. M.
    Laissy, J. P.
    Berhili, M.
    Brochet, E.
    Iung, B.
    Vahanian, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 899 - 899