Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography

被引:88
|
作者
Binder, TM
Rosenhek, R
Porenta, G
Maurer, G
Baumgartner, H
机构
[1] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Inst, Vienna, Austria
关键词
D O I
10.1016/S0735-1097(00)00852-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was performed to determine the feasibility, accuracy and reproducibility of real-time volumetric three-dimensional echocardiography (3-D echo) for the estimation of mitral valve area in patients with mitral valve stenosis. BACKGROUND Planimetry of the mitral valve area (MVA) by two-dimensional echocardiography (2-D echo) requires a favorable parasternal acoustic window and depends on operator skill. Transthoracic volumetric 3-D echo allows reconstruction of multiple 2-D planes in any desired orientation and is not limited to parasternal acquisition, and could thus enhance the accuracy and feasibility of calculating MVA. METHODS In 48 patients with mitral stenosis (40 women; mean age 61 +/- 13 years) MVA was determined by planimetry using volumetric 3-D echo and compared with measurements obtained by 2-D echo and Doppler pressure half-time (PHT). All measurements were performed by two independent observers. Volumetric data were acquired from an apical view. RESULTS Although 2-D echo allowed planimetry of the mitral valve in 43 of 48 patients (89%), calculation of the MVA was possible in all patients when 3-D echo was used. Mitral valve area by 3-D echo correlated well, with MVA by 2-D echo (r = 0.93, mean difference, 0.09 +/- 0.14 cm(2)) and by PHT (r = 0.87, mean difference, 0.16 +/- 0.19 cm(2)). Interobserver variability was significantly less for 3-D echo than for 2-D echo (SD 0.08 cm(2) versus SD 0.23 cm(2), p < 0.001). Furthermore, it was much easier and faster to define the image plane with the smallest orifice area when 3-D echo was used. CONCLUSIONS Transthoracic real-time volumetric 3-D echo provides accurate and highly reproducible measurements of mitral valve area and can easily be performed from an apical approach. (J Am Coll Cardiol 2000;36:1355-61) (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1355 / 1361
页数:7
相关论文
共 50 条
  • [1] Real-time three-dimensional transoesophageal echocardiography in the assessment of aortic valve stenosis
    de la Morena, Gonzalo
    Saura, Daniel
    Oliva, Maria J.
    Soria, Federico
    Gonzalez, Josefa
    Garcia, Miguel
    Moreno, Victoria
    Bonaque, Juan C.
    Valdes, Mariano
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (01): : 9 - 13
  • [3] Three-dimensional echocardiography for assessment of mitral valve stenosis
    Zamorano, Jose
    Alberto de Agustin, Jose
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (05) : 415 - 419
  • [4] New Scores for the Assessment of Mitral Stenosis Using Real-Time Three-Dimensional Echocardiography
    Soliman O.I.I.
    Anwar A.M.
    Metawei A.K.
    McGhie J.S.
    Geleijnse M.L.
    Ten Cate F.J.
    Current Cardiovascular Imaging Reports, 2011, 4 (5) : 370 - 377
  • [5] Real-Time Three-Dimensional Transesophageal Echocardiography in the Intraoperative Assessment of Mitral Valve Disease
    Grewal, Jasmine
    Mankad, Sunil
    Freeman, William K.
    Click, Roger L.
    Suri, Rakesh M.
    Abel, Martin D.
    Oh, Jae K.
    Pellikka, Patricia A.
    Nesbitt, Gillian C.
    Syed, Imran
    Mulvagh, Sharon L.
    Miller, Fletcher A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 34 - 41
  • [6] Real-time three-dimensional echocardiography in assessment of congenital double orifice mitral valve
    Lu Q.
    Lu X.
    Xie M.
    Wang X.
    Wang J.
    Yang Y.
    Yuan L.
    He L.
    Liu X.
    Fu M.
    Journal of Huazhong University of Science and Technology, 2006, 26 (5): : 625 - 628
  • [7] Real-time Three-dimensional Echocardiography in Assessment of Congenital Double Orifice Mitral Valve
    吕清
    卢晓芳
    谢明星
    王新房
    王静
    杨亚利
    袁莉
    贺林
    刘夏天
    付曼丽
    Current Medical Science, 2006, (05) : 625 - 628
  • [8] Assessing mitral valve area in calcific mitral stenosis: A new solution by real-time three-dimensional echocardiography
    Chu, JW
    Levine, RA
    Chua, S
    Ton-Nu, T
    Taub, C
    Sanz-Perez, T
    Morris, E
    Hua, LQ
    Hung, JW
    CIRCULATION, 2005, 112 (17) : U396 - U396
  • [9] Improved Assessment of the Mitral Annulus Using Real-Time Three-Dimensional Transesophageal Echocardiography
    Fernandez-Friera, L.
    Solis, J.
    Passeri, J.
    Handschumacher, M. D.
    Levine, R. A.
    Picard, M. H.
    CARDIOLOGY, 2010, 115 (04) : 268 - 268
  • [10] Validation of a New Score for the Assessment of Mitral Stenosis Using Real-Time Three-Dimensional Echocardiography
    Anwar, Ashraf M.
    Attia, Wael M.
    Nosir, Youssef F. M.
    Soliman, Osama I. I.
    Mosad, Mohammed A.
    Othman, Munir
    Geleijnse, Marcel L.
    El-Amin, Ali M.
    Ten Cate, Folkert J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (01) : 13 - 22