Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment

被引:16
|
作者
Huang, Xiaolei [1 ,2 ,4 ,5 ,6 ]
Dong, Hui [1 ,2 ,4 ,5 ]
Qiu, Yang [1 ,2 ,4 ,5 ,7 ]
Li, Bo [1 ,2 ,4 ,5 ,7 ]
Tao, Quan [1 ,2 ,3 ,4 ,5 ]
Zhang, Yi [3 ,4 ,5 ]
Krause, Hans-Joachim [3 ,4 ,5 ]
Offenhaeusser, Andreas [3 ,4 ,5 ]
Xie, Xiaoming [1 ,2 ,4 ,5 ]
机构
[1] Chinese Acad Sci, SIMIT, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[2] CAS Ctr ExcelleNce Superconducting Elect CENSE, Shanghai 200050, Peoples R China
[3] Forschungszentrum Julich FZJ, Inst Complex Syst ICS 8, D-52425 Julich, Germany
[4] Collaborat SIMIT, Joint Res Inst Funct Mat & Elect, Julich, Germany
[5] FZJ, Julich, Germany
[6] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[7] China Jiliang Univ, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultra-low field; Magnetic resonance imaging; Superconducting quantum interference device; Noise compensation; Power-line harmonics interference; MICROTESLA MRI; HUMAN BRAIN; IN-SITU; NOISE;
D O I
10.1016/j.jmr.2017.11.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel (s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [41] Signal-to-Noise Ratio Enhancement Method for Ultra-Low Field Magnetic Resonance Imaging Based on Low-Frequency Surface Metamaterials
    Kong, Xiaohan
    Zhang, Yana
    Wu, Jiamin
    He, Yucheng
    Xu, Zheng
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (13): : 3917 - 3927
  • [42] Development of ultra-low magnetic field sensors with magnetic tunnel junctions
    Pong, Philip W. T.
    Bonevich, John E.
    Egelhoff, William F., Jr.
    [J]. NANOENGINEERING: FABRICATION, PROPERTIES, OPTICS, AND DEVICES IV, 2007, 6645
  • [43] Interference-Resilient Ultra-Low Power Aperiodic Data Collection
    Istomin, Timofei
    Trobinger, Matteo
    Murphy, Amy L.
    Picco, Gian Pietro
    [J]. 2018 17TH ACM/IEEE INTERNATIONAL CONFERENCE ON INFORMATION PROCESSING IN SENSOR NETWORKS (IPSN), 2018, : 84 - 95
  • [44] MAGNETIC-RESONANCE-IMAGING OF THE UTERUS AT AN ULTRA LOW (0.02 T) MAGNETIC-FIELD
    VARPULA, M
    KOMU, M
    KLEMI, P
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (02) : 195 - 205
  • [45] BREAST-TUMOR IMAGING WITH ULTRA-LOW FIELD MRI
    DEAN, KI
    KOMU, M
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 395 - 401
  • [46] A numerical study of pre-polarisation switching in ultra-low field magnetic resonance imaging using dynamic permanent magnet arrays
    Pellicer-Guridi, Ruben
    Vogel, Michael W.
    Vegh, Viktor
    Su, Jiasheng
    Rosen, Matthew S.
    Reutens, David C.
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] A numerical study of pre-polarisation switching in ultra-low field magnetic resonance imaging using dynamic permanent magnet arrays
    Ruben Pellicer-Guridi
    Michael W. Vogel
    Viktor Vegh
    Jiasheng Su
    Matthew S. Rosen
    David C. Reutens
    [J]. Scientific Reports, 10
  • [48] A radical containing micellar probe for assessing esterase enzymatic activity with ultra-low field Overhauser-enhanced magnetic resonance imaging
    Elkhanoufi, Sabrina
    Rakhshan, Sahar
    Nespeca, Martin J.
    Alberti, Diego
    Boudries, Dahmane
    Pokong-Touyam, Joyce
    Stefania, Rachele
    Parzy, Elodie
    Massot, Philippe
    Mellet, Philippe
    Franconi, Jean-Michel
    Thiaudiere, Eric
    Crich, Simonetta Geninatti
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2024, : 10923 - 10933
  • [49] USEFULNESS OF INTRAOPERATIVE ULTRA LOW-FIELD MAGNETIC RESONANCE IMAGING IN GLIOMA SURGERY
    Senft, Christian
    Seifert, Volker
    Hermann, Elvis
    Franz, Kea
    Gasser, Thomas
    [J]. NEUROSURGERY, 2008, 63 (04) : 257 - 266