Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment

被引:16
|
作者
Huang, Xiaolei [1 ,2 ,4 ,5 ,6 ]
Dong, Hui [1 ,2 ,4 ,5 ]
Qiu, Yang [1 ,2 ,4 ,5 ,7 ]
Li, Bo [1 ,2 ,4 ,5 ,7 ]
Tao, Quan [1 ,2 ,3 ,4 ,5 ]
Zhang, Yi [3 ,4 ,5 ]
Krause, Hans-Joachim [3 ,4 ,5 ]
Offenhaeusser, Andreas [3 ,4 ,5 ]
Xie, Xiaoming [1 ,2 ,4 ,5 ]
机构
[1] Chinese Acad Sci, SIMIT, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[2] CAS Ctr ExcelleNce Superconducting Elect CENSE, Shanghai 200050, Peoples R China
[3] Forschungszentrum Julich FZJ, Inst Complex Syst ICS 8, D-52425 Julich, Germany
[4] Collaborat SIMIT, Joint Res Inst Funct Mat & Elect, Julich, Germany
[5] FZJ, Julich, Germany
[6] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[7] China Jiliang Univ, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultra-low field; Magnetic resonance imaging; Superconducting quantum interference device; Noise compensation; Power-line harmonics interference; MICROTESLA MRI; HUMAN BRAIN; IN-SITU; NOISE;
D O I
10.1016/j.jmr.2017.11.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel (s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [21] 3D-Spatial encoding with permanent magnets for ultra-low field magnetic resonance imaging
    Michael W. Vogel
    Ruben Pellicer Guridi
    Jiasheng Su
    Viktor Vegh
    David C. Reutens
    [J]. Scientific Reports, 9
  • [22] Toward a magnetic resonance electrical impedance tomography in ultra-low field: A direct magnetic resonance imaging method by an external alternating current
    Lee, Seong-Joo
    Shim, Jeong Hyun
    Yu, Kwon Kyu
    Hwang, Seong-min
    Oh, Sangwon
    Hilschenz, Ingo
    Kim, Kiwoong
    [J]. APPLIED PHYSICS LETTERS, 2018, 112 (15)
  • [23] Measurement of Magnetic Resonance Signal from a Rat Head in Ultra-low Magnetic Field
    Oyama, Daisuke
    Higuchi, Masanori
    Kawai, Jun
    Miyamoto, Masakazu
    Adachi, Yoshiaki
    Uehara, Gen
    Tsuyuguchi, Naohiro
    [J]. 2015 15TH INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2015,
  • [24] Ultra-Low Temperature Nuclear Magnetic Resonance
    Bouleau, Eric
    Lee, Daniel
    Saint-Bonnet, Pierre
    Hediger, Sabine
    De Paepe, Gael
    [J]. 26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [25] Ultra-low field frequency-swept electrically detected magnetic resonance
    Ashton, J. P.
    Manning, B. R.
    Barker, W. R.
    Lenahan, P. M.
    [J]. JOURNAL OF APPLIED PHYSICS, 2021, 129 (08)
  • [26] High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil
    Savukov, Igor
    Kim, Young Jin
    Newman, Shaun
    [J]. JOURNAL OF APPLIED PHYSICS, 2022, 132 (17)
  • [27] Auto-Adaptive Ultra-Low Power IC
    Bosio, A.
    Debaud, P.
    Girard, P.
    Guilhot, S.
    Valka, M.
    Virazel, A.
    [J]. 2016 11TH IEEE INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS), 2016,
  • [28] EVALUATION OF SYRINGOMYELIA AND CHIARI MALFORMATIONS USING ULTRA-LOW MAGNETIC-RESONANCE-IMAGING
    SAMUELSSON, L
    SAAF, J
    WAHLUND, LO
    THUOMAS, KA
    BERGSTROM, K
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (02) : 123 - 129
  • [29] On a ghost artefact in ultra low field magnetic resonance relaxation imaging
    Volegov, P.
    Schultz, L.
    Espy, M.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2014, 243 : 98 - 106
  • [30] A compact SQUID-detected magnetic resonance imaging system under microtesla field in a magnetically unshielded environment
    Chen, Hsin-Hsien
    Yang, Hong-Chang
    Horng, Herng-Er
    Liao, Shu-Hsien
    Yang, Shieh Yueh
    Wang, Li-Min
    [J]. JOURNAL OF APPLIED PHYSICS, 2011, 110 (09)