MAGNETIC-RESONANCE-IMAGING OF THE UTERUS AT AN ULTRA LOW (0.02 T) MAGNETIC-FIELD

被引:3
|
作者
VARPULA, M
KOMU, M
KLEMI, P
机构
[1] Department of Diagnostic Radiology, the University Central Hospital of Turku
[2] Department of Pathology, the University Central Hospital of Turku
关键词
UTERUS; MR STUDIES; RELAXATION TIMES; UTERINE NEOPLASMS;
D O I
10.1016/0730-725X(92)90480-N
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo pelvic imaging of 39 women and in vitro relaxation time measurements of four uterine specimens were performed using an ultra low field (0.02 T) MRI unit. Average T1 times measured in vitro at 37-degrees-C for the myometrium and endometrium were 206 ms (SD 47 ms) and 389 ms (SD 21 ms), respectively. Corresponding T2 times were 95 ms (SD 20 ms) and 167 ms (SD 13 ms). The proton relaxation of almost all myometrial specimens proved to be biexponential, but of all endometrial specimens was monoexponential. Contrast measurements between endometrium versus myometrium and myometrium versus the junctional zone were performed after imaging 18 volunteer women using different pulse sequence parameters. Normal uterine structures were optimally demonstrated by SE 700/70. Relatively short repetition times could be used, because spin-lattice relaxation times were short at the low magnetic field. Consequently, the short repetition times allowed averaging of four excitations to create adequate images within an acceptable scanning time. In addition to T2-weighted images a T1-weighted inversion recovery sequence with a short inversion time of 50 ms (IR 1000/50/40) adequately differentiated the three uterine zones. Although pathologic lesions of the uterus including leiomyomas, anomalies and carcinomas were well demonstrated, especially with the T2-weighted spin echo pulse sequence, further investigations are needed to evaluate the optimal technique for ultra low field MR imaging of uterine tumors.
引用
收藏
页码:195 / 205
页数:11
相关论文
共 50 条
  • [1] MAGNETIC-RESONANCE-IMAGING OF THE UTERUS IN-VIVO AND IN-VITRO AT AN ULTRA-LOW MAGNETIC-FIELD (0.02-T) - ASSESSMENT OF ITS NORMAL STRUCTURE AND OF LEIOMYOMAS
    VARPULA, M
    KIILHOLMA, P
    KLEMI, P
    KOMU, M
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (08) : 1139 - 1145
  • [2] LOW FIELD MAGNETIC-RESONANCE-IMAGING OF FOCAL HEPATIC MASSES AT 0.02 T
    EKELUND, L
    ATHLIN, L
    [J]. ACTA RADIOLOGICA, 1989, 30 (06) : 591 - 595
  • [3] MAGNETIC-RESONANCE-IMAGING OF FEMALE PELVIC MASSES AND LOCAL RECURRENT TUMORS AT AN ULTRA LOW (0.02-T) MAGNETIC-FIELD - CORRELATION WITH COMPUTED-TOMOGRAPHY
    VARPULA, M
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 35 - 46
  • [4] MAGNETIC-FIELD STRENGTH ISSUES IN MAGNETIC-RESONANCE-IMAGING
    MARSHALL, D
    HAILEY, D
    MENON, D
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (03): : 180 - 184
  • [5] LOW FIELD (0.02 T) NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE BRAIN
    SEPPONEN, RE
    SIPPONEN, JT
    SIVULA, A
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (02) : 237 - 241
  • [6] MAGNETIC-RESONANCE-IMAGING OF YOUNG AND AGED RAT BRAINS UNDER A MAGNETIC-FIELD OF 7.05-T
    KUWABARA, M
    ASANUMA, T
    INANAMI, O
    JIN, T
    SHIMOKAWA, S
    KASAI, N
    KATOR, K
    SATO, F
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 1994, 56 (05): : 933 - 938
  • [7] OPTIMIZING TECHNICAL CONDITIONS FOR MAGNETIC-RESONANCE-IMAGING OF THE RAT-BRAIN AND ABDOMEN IN A LOW MAGNETIC-FIELD
    YAMADA, K
    MIYAHARA, K
    SATO, M
    HIROSE, T
    YASUGI, Y
    MATSUDA, Y
    FURUHAMA, K
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 1995, 36 (06) : 523 - 527
  • [8] MAGNETIC-RESONANCE-IMAGING OF INTRACRANIAL NEOPLASMS AT 0.02 TESLA
    KORMANO, M
    RAININKO, R
    KATEVUO, K
    [J]. ACTA RADIOLOGICA, 1987, 28 (04) : 369 - 373
  • [9] MAGNETIC-RESONANCE-IMAGING AT 0.02-T IN CLINICAL-PRACTICE AND RESEARCH
    AGARTZ, I
    SAAF, J
    WAHLUND, LO
    WETTERBERG, L
    [J]. MAGNETIC RESONANCE IMAGING, 1987, 5 (03) : 179 - 187
  • [10] LOW-FIELD CINE MAGNETIC-RESONANCE-IMAGING
    JONES, RA
    METCALFE, MJ
    REDPATH, TW
    SMITH, FW
    WALTON, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (745): : 65 - 68