MAGNETIC-RESONANCE-IMAGING OF THE UTERUS AT AN ULTRA LOW (0.02 T) MAGNETIC-FIELD

被引:3
|
作者
VARPULA, M
KOMU, M
KLEMI, P
机构
[1] Department of Diagnostic Radiology, the University Central Hospital of Turku
[2] Department of Pathology, the University Central Hospital of Turku
关键词
UTERUS; MR STUDIES; RELAXATION TIMES; UTERINE NEOPLASMS;
D O I
10.1016/0730-725X(92)90480-N
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo pelvic imaging of 39 women and in vitro relaxation time measurements of four uterine specimens were performed using an ultra low field (0.02 T) MRI unit. Average T1 times measured in vitro at 37-degrees-C for the myometrium and endometrium were 206 ms (SD 47 ms) and 389 ms (SD 21 ms), respectively. Corresponding T2 times were 95 ms (SD 20 ms) and 167 ms (SD 13 ms). The proton relaxation of almost all myometrial specimens proved to be biexponential, but of all endometrial specimens was monoexponential. Contrast measurements between endometrium versus myometrium and myometrium versus the junctional zone were performed after imaging 18 volunteer women using different pulse sequence parameters. Normal uterine structures were optimally demonstrated by SE 700/70. Relatively short repetition times could be used, because spin-lattice relaxation times were short at the low magnetic field. Consequently, the short repetition times allowed averaging of four excitations to create adequate images within an acceptable scanning time. In addition to T2-weighted images a T1-weighted inversion recovery sequence with a short inversion time of 50 ms (IR 1000/50/40) adequately differentiated the three uterine zones. Although pathologic lesions of the uterus including leiomyomas, anomalies and carcinomas were well demonstrated, especially with the T2-weighted spin echo pulse sequence, further investigations are needed to evaluate the optimal technique for ultra low field MR imaging of uterine tumors.
引用
收藏
页码:195 / 205
页数:11
相关论文
共 50 条
  • [41] On a ghost artefact in ultra low field magnetic resonance relaxation imaging
    Volegov, P.
    Schultz, L.
    Espy, M.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2014, 243 : 98 - 106
  • [42] EVALUATION OF SYRINGOMYELIA AND CHIARI MALFORMATIONS USING ULTRA-LOW MAGNETIC-RESONANCE-IMAGING
    SAMUELSSON, L
    SAAF, J
    WAHLUND, LO
    THUOMAS, KA
    BERGSTROM, K
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (02) : 123 - 129
  • [43] LOW FIELD MAGNETIC-RESONANCE-IMAGING OF THE CANINE CENTRAL-NERVOUS-SYSTEM
    KARKKAINEN, M
    MERO, M
    NUMMI, P
    PUNTO, L
    [J]. VETERINARY RADIOLOGY, 1991, 32 (02): : 71 - 77
  • [44] EARTHS FIELD MAGNETIC-RESONANCE-IMAGING IN DISTURBED ENVIRONMENT
    FAVRE, B
    BONCHE, JP
    MEHIER, H
    [J]. BULLETIN OF MAGNETIC RESONANCE, VOL 11, NOS 3/4: PROCEEDINGS OF THE INTERNATIONAL SOCIETY OF MAGNETIC RESONANCE TENTH MEETING, 1989, : 385 - 385
  • [45] MAGNETIC-RESONANCE-IMAGING OF THE HEART
    PENNELL, DJ
    UNDERWOOD, SR
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (02): : 90 - &
  • [46] MAGNETIC-RESONANCE-IMAGING OF THE KNEE
    KURSUNOGLUBRAHME, S
    RESNICK, D
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1990, 21 (03) : 561 - 572
  • [47] MAGNETIC-RESONANCE-IMAGING OF THE WRIST
    DALINKA, MK
    MEYER, S
    KRICUN, ME
    VANEL, D
    [J]. HAND CLINICS, 1991, 7 (01) : 87 - 98
  • [48] A VENTILATOR FOR MAGNETIC-RESONANCE-IMAGING
    HEDLUND, LW
    DEITZ, J
    NASSAR, R
    HERFKENS, R
    VOCK, P
    DAHLKE, J
    KUBEK, R
    EFFMANN, EL
    PUTMAN, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1986, 21 (01) : 18 - 23
  • [49] MAGNETIC-RESONANCE-IMAGING OF CRANIOPHARYNGIOMAS
    TWINING, P
    WORTHINGTON, BS
    MAWHINNEY, RR
    HOLLAND, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 796 - 796
  • [50] MAGNETIC-RESONANCE-IMAGING OF THE MEDIASTINUM
    POON, PY
    BRONSKILL, MJ
    HENKELMAN, RM
    DUNLAP, HJ
    BLEND, R
    HERMAN, S
    MAJESKY, IF
    GINSBERG, RJ
    [J]. JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1986, 37 (03): : 173 - 181