BREAST-TUMOR IMAGING WITH ULTRA-LOW FIELD MRI

被引:10
|
作者
DEAN, KI
KOMU, M
机构
[1] Department of Diagnostic Radiology, University of Turku
关键词
BREAST; BREAST NEOPLASMS; MR STUDIES; RELAXATION TIMES; MAGNETIC RESONANCE (MR); TISSUE CHARACTERIZATION;
D O I
10.1016/0730-725X(94)92532-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultra low field MRI was evaluated for breast tumor imaging. Twenty-seven patients with a known or suspected breast malignancy were imaged preoperatively with a T-2-weighted gradient-echo sequence. Additional IR- and gradient-echo sequences were used for measurements of T-1 and T-2 relaxation times. Seventeen resected specimens were also imaged within four hours after removal. Nineteen of 23 carcinomas detected at mammography were also detected with MRI (sensitivity 83%), and one of four benign cases was evaluated as pathologic (specificity 75%). Most of the tumors had T-1 and T-2 relaxation times longer than those of normal breast parenchyma. The T-1 values of the tumors were significantly different from the T-1 values of fat (p =.0002) and breast parenchyma (p =.0151). The tumor T-2 values differed significantly from the T-2 of breast parenchyma (p =.0223) but not from that of fat (p =.1475). In vitro tumor measurements were similar to the in vivo measurements. Despite these statistically significant findings, the calculated relaxation times were not considered sufficiently reliable for the clinical evaluation of breast tumors.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 50 条
  • [1] Hyperpolarized Xenon Imaging with the SWIFT Approach in Ultra-low Field MRI: A Simulation Study
    Kaga, Yuki
    Oida, Takenori
    Kobayashi, Tetsuo
    [J]. ADVANCED BIOMEDICAL ENGINEERING, 2015, 4 : 42 - 47
  • [2] Demonstration of full tensor current density imaging using ultra-low field MRI
    Hoemmen, P.
    Storm, J-H
    Hoefner, N.
    Koerber, R.
    [J]. MAGNETIC RESONANCE IMAGING, 2019, 60 : 137 - 144
  • [3] Molecular Breast Imaging at Ultra-Low Radiation Dose
    Covington, Matthew F.
    Brown, Matthew
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : W30 - W30
  • [4] Non-cryogenic anatomical imaging in ultra-low field regime: Hand MRI demonstration
    Savukov, I.
    Karaulanov, T.
    Castro, A.
    Volegov, P.
    Matlashov, A.
    Urbatis, A.
    Gomez, J.
    Espy, M.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2011, 211 (02) : 101 - 108
  • [5] Ultra-low field MRI food inspection system prototype
    Kawagoe, Satoshi
    Toyota, Hirotomo
    Hatta, Junichi
    Ariyoshi, Seiichiro
    Tanaka, Saburo
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2016, 530 : 104 - 108
  • [6] Design of biplanar shim coils for ultra-low field MRI
    He, Yucheng
    He, Wei
    Xiong, Bingquan
    Guo, Pan
    Xu, Zheng
    [J]. INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2018, 58 (03) : 359 - 370
  • [7] Progress Toward a Deployable SQUID-Based Ultra-Low Field MRI System for Anatomical Imaging
    Espy, Michelle
    Magnelind, Per
    Matlashov, Andrei
    Newman, Shaun
    Sandin, Henrik
    Schultz, Larry
    Sedillo, Robert
    Urbaitis, Algis
    Volegov, Petr
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [8] MAGNETIC CONTAMINANT IMAGING USING HIGH-TC SQUID ULTRA-LOW FIELD MRI TECHNOLOGIES
    Tanaka, Saburo
    Tsunaki, S.
    Yamamoto, M.
    Hatsukade, Y.
    Hatta, J.
    [J]. 2013 INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2013,
  • [9] SQUIDs for Magnetic Resonance Imaging at Ultra-low Magnetic Field
    Matlashov, A. N.
    Zotev, V. S.
    Kraus, R. H., Jr.
    Sandin, H.
    Urbaitis, A. V.
    Volegov, P. L.
    Espy, M. A.
    [J]. PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 802 - 806
  • [10] Ultra-sensitive SQUID systems for applications in biomagnetism and ultra-low field MRI
    Koerber, Rainer
    Kieler, Oliver
    Hommen, Peter
    Hoefner, Nora
    Storm, Jan-Hendrik
    [J]. 2019 IEEE INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2019,