Design Study of the Absorber Detector of a Compton Camera for On-Line Control in Ion Beam Therapy

被引:22
|
作者
Richard, M. -H. [1 ,2 ,3 ]
Dahoumane, M. [1 ,2 ]
Dauvergne, D. [1 ,2 ]
De Rydt, M. [1 ,2 ,4 ]
Dedes, G. [1 ,2 ]
Freud, N. [3 ]
Krimmer, J. [1 ,2 ]
Letang, J. M. [3 ]
Lojacono, X. [3 ]
Maxim, V. [3 ]
Montarou, G. [5 ]
Ray, C. [1 ,2 ]
Roellinghoff, F. [3 ]
Testa, E. [1 ,2 ]
Walenta, A. H. [1 ,2 ]
机构
[1] Univ Lyon, F-69622 Lyon, France
[2] Univ Lyon 1, CNRS, IN2P3, UMR 5822,IPNL, F-69622 Villeurbanne, France
[3] Univ Lyon 1, INSA Lyon, INSERM U1044, CREATIS,CNRS UMR 5220,Ctr Leon Berard, F-69622 Villeurbanne, France
[4] Katholieke Univ Leuven, Inst Kern En Stralingsfys, B-3001 Louvain, Belgium
[5] Clermont Univ, CNRS, IN2P3, UMR 6533,LPC Clermont, F-63177 Aubiere, France
关键词
BGO; Compton camera; Geant4; hadrontherapy; ion beam therapy; LaBr3; LYSO; NaI; prompt gamma-ray; PROTON THERAPY; GAMMA; SIMULATION;
D O I
10.1109/TNS.2012.2206053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The goal of this study is to tune the design of the absorber detector of a Compton camera for prompt gamma-ray imaging during ion beam therapy. The response of the Compton camera to a photon point source with a realistic energy spectrum (corresponding to the prompt gamma-ray spectrum emitted during the carbon irradiation of a water phantom) is studied by means of Geant4 simulations. Our Compton camera consists of a stack of 2 mm thick silicon strip detectors as a scatter detector and of a scintillator plate as an absorber detector. Four scintillators are considered: LYSO, NaI, LaBr3 and BGO. LYSO and BGO appear as the most suitable materials, due to their high photo-electric cross-sections, which leads to a high percentage of fully absorbed photons. Depth-of-interaction measurements are shown to have limited influence on the spatial resolution of the camera. In our case, the thickness which gives the best compromise between a high percentage of photons that are fully absorbed and a low parallax error is about 4 cm for the LYSO detector and 4.5 cm for the BGO detector. The influence of the width of the absorber detector on the spatial resolution is not very pronounced as long as it is lower than 30 cm.
引用
收藏
页码:1850 / 1855
页数:6
相关论文
共 50 条
  • [1] Design Study of the Absorber Detector of a Compton Camera for On-line Control in Ion Beam Therapy
    Richard, M. -H.
    Dahoumane, M.
    Dauvergne, D.
    Dedes, G.
    De Rydt, M.
    Freud, N.
    Letang, J. M.
    Lojacono, X.
    Krimmer, J.
    Maxim, V.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Walenta, A. H.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3496 - 3500
  • [2] Design Study of a Compton Camera for Prompt γ Imaging During Ion Beam Therapy
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4172 - +
  • [3] Design of a Compton camera for 3D prompt-γ imaging during ion beam therapy
    Roellinghoff, F.
    Richard, M. -H.
    Chevallier, M.
    Constanzo, J.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S20 - S23
  • [4] Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility
    Fontana, M.
    Ley, J. -L.
    Dauvergne, D.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Maxim, V.
    Richard, M. -H.
    Rinaldi, I.
    Testa, E.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 218 - 232
  • [5] Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 87 - 94
  • [6] Optimization and verification of image reconstruction for a Compton camera towards application as an on-line monitor for particle therapy
    Taya, T.
    Kataoka, J.
    Kishimoto, A.
    Tagawa, L.
    Mochizuki, S.
    Toshito, T.
    Kimura, M.
    Nagao, Y.
    Kurita, K.
    Yamaguchi, M.
    Kawachi, N.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [7] A Compton Imaging Algorithm for On-line Monitoring in Hadron Therapy
    Gillam, J. E.
    Lacasta, C.
    Torres-Espallardo, I.
    Candela Juan, C.
    Llosa, G.
    Solevi, P.
    Barrio, J.
    Rafecas, M.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [8] Design and material considerations for a 3D-position sensitive scintillation detector as absorber for a high resolution Compton-Camera
    Uhlmann, N
    Wölfel, S
    Giersch, K
    Pauli, J
    Anton, G
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3682 - 3686
  • [9] 3D-position sensitive compact scintillation detector as absorber for a Compton-Camera
    Uhlmann, N
    Wölfel, S
    Pauli, J
    Anton, G
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2149 - 2152
  • [10] 3D-position-sensitive compact scintillation detector as absorber for a Compton-camera
    Uhlmann, N
    Wölfel, S
    Pauli, J
    Anton, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 606 - 611