Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study

被引:74
|
作者
Richard, M. -H. [1 ,2 ,3 ,7 ]
Chevallier, M. [1 ,2 ,7 ]
Dauvergne, D. [1 ,2 ,7 ]
Freud, N. [3 ]
Henriquet, P. [1 ,2 ,7 ]
Le Foulher, F. [1 ,2 ,7 ]
Letang, J. M. [3 ]
Montarou, G. [4 ,5 ]
Ray, C. [1 ,2 ,7 ]
Roellinghoff, F. [1 ,2 ,7 ]
Testa, E. [1 ,2 ,7 ]
Testa, M. [1 ,2 ,7 ]
Walenta, A. H. [6 ]
机构
[1] Univ Lyon, F-69622 Lyon, France
[2] Univ Lyon 1, F-69622 Villeurbanne, France
[3] INSA Lyon Lab Nondestruct Testing Using Ionizing, F-69621 Villeurbanne, France
[4] Clermont Univ, F-63177 Aubiere, France
[5] CNRS, IN2P3, LPC Clermont, UMR 6533, F-63177 Aubiere, France
[6] Uni Siegen, FB Phys, D-57068 Siegen, Germany
[7] CNRS, IN2P3, IPNL, UMR 5822, F-69622 Villeurbanne, France
关键词
Compton camera; Geant4; hadrontherapy; ion beam therapy; prompt gamma; X-RAY; PROTON; RESOLUTION;
D O I
10.1109/TNS.2010.2076303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In hadrontherapy in order to fully take advantage of the assets of the ion irradiation, the position of the Bragg peak has to be monitored accurately. Here, we investigate a monitoring method relying on the detection in real time of the prompt emitted quasi instantaneously during the nuclear fragmentation processes. Our detection system combines a beam hodoscope and a double scattering Compton camera. The prompt-gamma emission points are reconstructed by intersecting the ion trajectories given by the hodoscope and the Compton cones reconstructed with the camera. We propose here to study in terms of point spread function and efficiency the theoretical feasibility of the emission points reconstruction with our set-up in the case of a photon point source in air. First we analyze the nature of all the interactions which are likely to produce an energy deposit in the three detectors of the camera. It is underlined that upper energy thresholds in both scatter detectors are required in order to select mainly Compton events (one Compton interaction in each scatter detector and one interaction in the absorber detector). Then, we study the influence of various parameters such as the photon energy and the inter-detector distances on the Compton camera response. These studies are carried out by means of Geant4 simulations. We use a source with a spectrum corresponding to the prompt-spectrum emitted during the carbon ion irradiation of a water phantom. In the current configuration, the spatial resolution of the Compton camera is about 6 mm (Full Width at Half Maximum) and the detection efficiency 10(-5). Finally, provided the detection efficiency is increased, the clinical applicability of our system is considered.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 50 条
  • [1] Design of a Compton camera for 3D prompt-γ imaging during ion beam therapy
    Roellinghoff, F.
    Richard, M. -H.
    Chevallier, M.
    Constanzo, J.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S20 - S23
  • [2] Design Study of a Compton Camera for Prompt γ Imaging During Ion Beam Therapy
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4172 - +
  • [3] Low Statistics Reconstruction of the Compton Camera Point Spread Function in 3D Prompt-γ Imaging of Ion Beam Therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ley, Jean-Luc
    Testa, Etienne
    Ray, Cedric
    Freud, Nicolas
    Letang, Jean Michel
    Dauvergne, Denis
    Maxim, Voichita
    Prost, Remy
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3355 - 3363
  • [4] Monte Carlo simulation study on medical imaging of a multiply stacked Compton camera
    Kim, N. Y.
    Lee, C. S.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (02) : 1201 - 1204
  • [5] Image reconstruction for Compton camera applied to 3D prompt γ imaging during ion beam therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ray, Cedric
    Dauvergne, Denis
    Testa, Etienne
    Freud, Nicolas
    Letang, Jean Michel
    Maxim, Voichita
    Prost, Remy
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3518 - 3521
  • [6] Monte Carlo simulation of prompt-γ emission in proton therapy using a track length estimator
    Letang, J. M.
    El Kanawati, W.
    Dauvergne, D.
    Pinto, M.
    Sarrut, D.
    Testa, E.
    Freud, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S67 - S67
  • [7] Monte Carlo simulations on performance of double-scattering Compton camera
    Park, J. H.
    Seo, H.
    Kim, Y. S.
    Kim, C. H.
    Lee, J. H.
    Lee, C. S.
    Kim, S. M.
    Lee, J. S.
    [J]. JOURNAL OF INSTRUMENTATION, 2012, 7
  • [8] Monte Carlo study of a double-scattering Compton camera with GEANT4
    Seo, Hee
    An, So Hyun
    Kim, Jong Kyung
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 314 - 317
  • [9] Monitoring the distribution of prompt gamma rays in boron neutron capture therapy using a multiple-scattering Compton camera: A Monte Carlo simulation study
    Lee, Taewoong
    Lee, Hyounggun
    Lee, Wonho
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 798 : 135 - 139
  • [10] Monitoring of Dose Distribution in Photon Therapy With Multiple-Scattering Compton Camera: A Monte Carlo Simulation Study
    Lee, Taewoong
    Lee, Hyounggun
    Lee, Wonho
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (06) : 2801 - 2806