Design of a Compton camera for 3D prompt-γ imaging during ion beam therapy

被引:71
|
作者
Roellinghoff, F. [1 ,2 ,3 ,4 ]
Richard, M. -H. [1 ,2 ,3 ,4 ]
Chevallier, M. [1 ,2 ,3 ]
Constanzo, J. [1 ,2 ,3 ]
Dauvergne, D. [1 ,2 ,3 ]
Freud, N. [4 ]
Henriquet, P. [1 ,2 ,3 ]
Le Foulher, F. [1 ,2 ,3 ]
Letang, J. M. [4 ]
Montarou, G. [5 ]
Ray, C. [1 ,2 ,3 ]
Testa, E. [1 ,2 ,3 ]
Testa, M. [1 ,2 ,3 ]
Walenta, A. H. [6 ]
机构
[1] Univ Lyon 1, F-69622 Villeurbanne, France
[2] Univ Lyon, F-69622 Lyon, France
[3] IPNL, CNRS, UMR 5822, IN2P3, F-69622 Villeurbanne, France
[4] Inst Natl Sci Appl, Lab Nondestruct Testing Using Ionizing Radiat CND, F-69621 Villeurbanne, France
[5] Clermont F Univ, CNRS, IN2P3, LPC, Clermont Ferrand, France
[6] Uni Siegen, FB Phys, D-57068 Siegen, Germany
关键词
Compton camera; Hadrontherapy; Ion beam therapy; Prompt gamma; Geant4;
D O I
10.1016/j.nima.2011.01.069
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We investigate, by means of Geant4 simulations, a real-time method to control the position of the Bragg peak during ion therapy, based on a Compton camera in combination with a beam tagging device (hodoscope) in order to detect the prompt gamma emitted during nuclear fragmentation. The proposed set-up consists of a stack of 2 mm thick silicon strip detectors and a LYSO absorber detector. The gamma emission points are reconstructed analytically by intersecting the ion trajectories given by the beam hodoscope and the Compton cones given by the camera. The camera response to a polychromatic point source in air is analyzed with regard to both spatial resolution and detection efficiency. Various geometrical configurations of the camera have been tested. In the proposed configuration, for a typical polychromatic photon point source, the spatial resolution of the camera is about 8.3 mm FWHM and the detection efficiency 2.5 x 10(-4) (reconstructable photons/emitted photons in 4 pi). Finally, the clinical applicability of our system is considered and possible starting points for further developments of a prototype are discussed. (c) 2011 Published by Elsevier B.V.
引用
收藏
页码:S20 / S23
页数:4
相关论文
共 50 条
  • [1] Low Statistics Reconstruction of the Compton Camera Point Spread Function in 3D Prompt-γ Imaging of Ion Beam Therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ley, Jean-Luc
    Testa, Etienne
    Ray, Cedric
    Freud, Nicolas
    Letang, Jean Michel
    Dauvergne, Denis
    Maxim, Voichita
    Prost, Remy
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3355 - 3363
  • [2] Image reconstruction for Compton camera applied to 3D prompt γ imaging during ion beam therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ray, Cedric
    Dauvergne, Denis
    Testa, Etienne
    Freud, Nicolas
    Letang, Jean Michel
    Maxim, Voichita
    Prost, Remy
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3518 - 3521
  • [3] Design Study of a Compton Camera for Prompt γ Imaging During Ion Beam Therapy
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4172 - +
  • [4] Design Guidelines for a Double Scattering Compton Camera for Prompt-γ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 87 - 94
  • [5] Clinical applicability of the Compton camera for Prompt γ-ray Imaging during proton therapy
    Rohling, H.
    Priegnitz, M.
    Schoene, S.
    Schumann, A.
    Enghardt, W.
    Golnik, C.
    Hueso-Gonzalez, F.
    Kormoll, T.
    Pausch, G.
    Petzoldt, J.
    Roemer, K.
    Fiedler, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S90 - S91
  • [6] Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation
    Hilaire, Estelle
    Sarrut, David
    Peyrin, Francoise
    Maxim, Voichita
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08): : 3127 - 3147
  • [7] Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification
    Gutierrez, A.
    Baker, C.
    Boston, H.
    Chung, S.
    Judson, D. S.
    Kacperek, A.
    Le Crom, B.
    Moss, R.
    Royle, G.
    Speller, R.
    Boston, A. J.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [8] Prompt Gamma Imaging of a Pencil Beam with a High Efficiency Compton Camera at a Clinical Proton Therapy Facility
    Hueso-Gonzalez, F.
    Petzoldt, J.
    Roemer, K. E.
    Schoene, S.
    Fiedler, F.
    Golnik, C.
    Kormoll, T.
    Pausch, G.
    Enghardt, W.
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [9] Evaluation of a multistage CdZnTe Compton camera for prompt γ imaging for proton therapy
    McCleskey, M.
    Kaye, W.
    Mackin, D. S.
    Beddar, S.
    He, Z.
    Polf, J. C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 785 : 163 - 169
  • [10] Test of Compton camera components for prompt gamma imaging at the ELBE bremsstrahlung beam
    Hueso-Gonzalez, F.
    Golnik, C.
    Berthel, M.
    Dreyer, A.
    Enghardt, W.
    Fiedler, F.
    Heidel, K.
    Kormoll, T.
    Rohling, H.
    Schoene, S.
    Schwengner, R.
    Wagner, A.
    Pausch, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9