Design of a Compton camera for 3D prompt-γ imaging during ion beam therapy

被引:71
|
作者
Roellinghoff, F. [1 ,2 ,3 ,4 ]
Richard, M. -H. [1 ,2 ,3 ,4 ]
Chevallier, M. [1 ,2 ,3 ]
Constanzo, J. [1 ,2 ,3 ]
Dauvergne, D. [1 ,2 ,3 ]
Freud, N. [4 ]
Henriquet, P. [1 ,2 ,3 ]
Le Foulher, F. [1 ,2 ,3 ]
Letang, J. M. [4 ]
Montarou, G. [5 ]
Ray, C. [1 ,2 ,3 ]
Testa, E. [1 ,2 ,3 ]
Testa, M. [1 ,2 ,3 ]
Walenta, A. H. [6 ]
机构
[1] Univ Lyon 1, F-69622 Villeurbanne, France
[2] Univ Lyon, F-69622 Lyon, France
[3] IPNL, CNRS, UMR 5822, IN2P3, F-69622 Villeurbanne, France
[4] Inst Natl Sci Appl, Lab Nondestruct Testing Using Ionizing Radiat CND, F-69621 Villeurbanne, France
[5] Clermont F Univ, CNRS, IN2P3, LPC, Clermont Ferrand, France
[6] Uni Siegen, FB Phys, D-57068 Siegen, Germany
关键词
Compton camera; Hadrontherapy; Ion beam therapy; Prompt gamma; Geant4;
D O I
10.1016/j.nima.2011.01.069
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We investigate, by means of Geant4 simulations, a real-time method to control the position of the Bragg peak during ion therapy, based on a Compton camera in combination with a beam tagging device (hodoscope) in order to detect the prompt gamma emitted during nuclear fragmentation. The proposed set-up consists of a stack of 2 mm thick silicon strip detectors and a LYSO absorber detector. The gamma emission points are reconstructed analytically by intersecting the ion trajectories given by the beam hodoscope and the Compton cones given by the camera. The camera response to a polychromatic point source in air is analyzed with regard to both spatial resolution and detection efficiency. Various geometrical configurations of the camera have been tested. In the proposed configuration, for a typical polychromatic photon point source, the spatial resolution of the camera is about 8.3 mm FWHM and the detection efficiency 2.5 x 10(-4) (reconstructable photons/emitted photons in 4 pi). Finally, the clinical applicability of our system is considered and possible starting points for further developments of a prototype are discussed. (c) 2011 Published by Elsevier B.V.
引用
收藏
页码:S20 / S23
页数:4
相关论文
共 50 条
  • [21] 3D image reconstruction for a Compton SPECT camera model
    Univ of Michigan, Ann Arbor, United States
    [J]. IEEE Trans Nucl Sci, 6 III (2075-2084):
  • [22] 3D image reconstruction for a Compton SPECT camera model
    Sauve, AC
    Hero, AO
    Rogers, WL
    Wilderman, SJ
    Clinthorne, NH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2075 - 2084
  • [23] IMAGING OF POINT SOURCES WITH A COMPTON CAMERA FOR IN-VIVO DOSE MONITORING OF ION BEAM IRRADIATION
    Kormoll, T.
    Fiedler, F.
    Golnik, C.
    Heidel, K.
    Kempe, M.
    Schoene, S.
    Sobiella, M.
    Zuber, K.
    Enghardt, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S41 - S42
  • [24] In vivo verification of particle therapy: how Compton camera configurations affect 3D image quality
    Mackin, D.
    Draeger, E.
    Peterson, S.
    Polf, J.
    Beddar, S.
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [25] A feasibility study using an array of LaBr3(Ce) scintillation detectors as a Compton camera for prompt gamma imaging during BNCT
    Nutter, Kiran
    Price, Tony
    Kokalova, Tzany
    Green, Stuart
    Phoenix, Ben
    [J]. FRONTIERS IN PHYSICS, 2024, 12
  • [26] 3D imaging camera for gaming application
    Yahav, G.
    Iddan, G. J.
    Mandelboum, D.
    [J]. ICCE: 2007 DIGEST OF TECHNICAL PAPERS INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 2007, : 417 - +
  • [27] 3-D imaging of complex source fields with a Compton Camera Imager
    McKisson, JE
    Haskins, PS
    Henderson, DP
    Neelands, KC
    Wang, CK
    Evans, T
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 825 - 829
  • [28] Annihilation gamma imaging for carbon ion beam range monitoring using Si/CdTe Compton camera
    Parajuli, Raj Kumar
    Sakai, Makoto
    Kada, Wataru
    Torikai, Kota
    Kikuchi, Mikiko
    Arakawa, Kazuo
    Torikoshi, Masami
    Nakano, Takashi
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05):
  • [29] Vertical Design of 3D Camera Platform
    Dong, Yulong
    Dong, Yue
    Liu, Jiefeng
    Wu, Xianting
    [J]. 2019 4TH INTERNATIONAL CONFERENCE ON CONTROL AND ROBOTICS ENGINEERING (ICCRE), 2019, : 156 - 160
  • [30] The Mathematical Foundations of 3D Compton Scatter Emission Imaging
    Truong, T. T.
    Nguyen, M. K.
    Zaidi, H.
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007