Monte Carlo simulations on performance of double-scattering Compton camera

被引:5
|
作者
Park, J. H. [1 ]
Seo, H. [1 ]
Kim, Y. S. [1 ]
Kim, C. H. [1 ]
Lee, J. H. [2 ]
Lee, C. S. [2 ]
Kim, S. M. [3 ]
Lee, J. S. [3 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
[3] Seoul Natl Univ, Dept Nucl Engn, Seoul 110744, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Models and simulations; Compton imaging; EMISSION COMPUTED-TOMOGRAPHY; COLLIMATED GAMMA-CAMERA; RESOLUTION; DETECTOR;
D O I
10.1088/1748-0221/7/01/C01009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A double-scattering Compton camera that can effectively obtain three-dimensional emission images in high-energy gamma-ray applications such as nuclear decommissioning and particle therapy monitoring has been developed. The double-scattering Compton camera utilizes two position-sensitive detectors as scatter detectors to determine the trajectory of a scattered gammaray, and a scintillation detector as absorber detector to measure the remaining energy of the double-scattered gamma-ray. The benefit of using two scatter detectors is the accurate determination of the gamma-ray trajectory after the scattering at the first scatter detector, which makes possible higher imaging resolution. In the present study, Geant4 Monte Carlo simulations were conducted to compare the performance of the double-scattering Compton camera with that of a similarly dimensioned single-scattering Compton camera for different source energies. Further, the optimal geometry of the multiple-detector-type double-scattering Compton camera was investigated for the purposes of increasing its imaging sensitivity. The results showed that the double-scattering Compton camera offers superior angular resolution over the entire energy range considered in the present study, whereas the single-scattering Compton camera provides greater sensitivity. The results also showed that, in general, the placement of additional detectors in the axial direction (i.e., stacking) is more effective for sensitivity improvement than doing so in the planar direction. This axial placement, however, lowers the imaging resolution. The double-scattering Compton camera exhibited the highest sensitivity when the additional scatter detectors were added to the first scatter detector in the axial direction, and exhibited the highest imaging resolution when the additional detectors were added to first scatter detector in the planar direction. Therefore, the results generally indicated that the first scatter detector is more important than the second not only for improving the sensitivity but also for maintaining a high imaging resolution. We believe that the present study's findings will provide valuable guidelines to researchers looking for the best Compton camera designs for certain objectives.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Monte Carlo study of a double-scattering Compton camera with GEANT4
    Seo, Hee
    An, So Hyun
    Kim, Jong Kyung
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 314 - 317
  • [2] Experimental performance of double-scattering Compton camera with anthropomorphic phantom
    Seo, H.
    Park, J. H.
    Ushakov, A.
    Kim, C. H.
    Kim, J. K.
    Lee, J. H.
    Lee, C. S.
    Lee, J. S.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6
  • [3] An Integrated Framework Based on Full Monte Carlo Simulations for Double-Scattering Proton Therapy
    Yuan, Jiankui
    Mansur, David
    Yao, Min
    Biswas, Tithi
    Zheng, Yiran
    Jesseph, Rick
    Jin, Jian-Yue
    Machtay, Mitchell
    [J]. INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2019, 6 (02): : 31 - 41
  • [4] Monte Carlo simulations of the performance of a Compton camera consisting of position-sensitive germanium detectors
    Yang, YF
    Gono, Y
    Motomura, S
    Enomoto, S
    Yano, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 482 (03): : 806 - 813
  • [5] Optimal geometrical configuration of a double-scattering compton camera for maximum imaging resolution and sensitivity
    Seo, Hee
    Lee, Se Hyung
    Kim, Chan Hyeong
    An, So Hyun
    Lee, Ju Hahn
    Lee, Chun Sik
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 80 - 83
  • [6] FPGA-Based Interface of Digital DAQ System for Double-Scattering Compton Camera
    Kim S.M.
    Kim Y.S.
    [J]. Nuclear Medicine and Molecular Imaging, 2018, 52 (6) : 430 - 437
  • [7] A Monte Carlo Based Plan Verification Framework for Double-Scattering Proton Therapy
    Yuan, J.
    Mansur, D.
    Yao, M.
    Biswas, T.
    Jesseph, R.
    Jin, J.
    Machtay, M.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E551 - E551
  • [8] A Beam Source Model for Monte Carlo Simulations of a Double-Scattering Proton Beam Delivery System Using Beam Current Modulation
    Shin, J.
    Merchant, T. E.
    Lee, S.
    Li, Z.
    Shin, D.
    Farr, J. B.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3332 - 3332
  • [9] A Monte Carlo evaluation of three Compton camera absorbers
    C. Z. Uche
    W. H. Round
    M. J. Cree
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 351 - 360
  • [10] A Monte Carlo evaluation of three Compton camera absorbers
    Uche, C. Z.
    Round, W. H.
    Cree, M. J.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) : 351 - 360