Optimization and verification of image reconstruction for a Compton camera towards application as an on-line monitor for particle therapy

被引:21
|
作者
Taya, T. [1 ]
Kataoka, J. [1 ]
Kishimoto, A. [1 ]
Tagawa, L. [1 ]
Mochizuki, S. [1 ]
Toshito, T. [2 ]
Kimura, M. [2 ]
Nagao, Y. [3 ]
Kurita, K. [3 ]
Yamaguchi, M. [3 ]
Kawachi, N. [3 ]
机构
[1] Waseda Univ, Grad Sch Adv Sci & Engn, Shinjuku Ku, 3-4-1 Okubu, Tokyo, Japan
[2] Nagoya Proton Therapy Ctr, Kita Ku, 1-1-1 Hirate Cho, Nagoya, Aichi, Japan
[3] Natl Inst Quantum & Radiol Sci & Technol, Takasaki Adv Radiat Res Inst, Quantum Beam Sci Res Directorate, 1233 Watanuki Machi, Takasaki, Gunma, Japan
来源
关键词
Compton imaging; Image reconstruction in medical imaging;
D O I
10.1088/1748-0221/12/07/P07015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Particle therapy is an advanced cancer therapy that uses a feature known as the Bragg peak, in which particle beams suddenly lose their energy near the end of their range. The Bragg peak enables particle beams to damage tumors effectively. To achieve precise therapy, the demand for accurate and quantitative imaging of the beam irradiation region or dosage during therapy has increased. The most common method of particle range verification is imaging of annihilation gamma rays by positron emission tomography. Not only 511-keV gamma rays but also prompt gamma rays are generated during therapy; therefore, the Compton camera is expected to be used as an on-line monitor for particle therapy, as it can image these gamma rays in real time. Proton therapy, one of the most common particle therapies, uses a proton beam of approximately 200 MeV, which has a range of similar to 25 cm in water. As gamma rays are emitted along the path of the proton beam, quantitative evaluation of the reconstructed images of diffuse sources becomes crucial, but it is far from being fully developed for Compton camera imaging at present. In this study, we first quantitatively evaluated reconstructed Compton camera images of uniformly distributed diffuse sources, and then confirmed that our Compton camera obtained 3 %(1 sigma) and 5 %(1 sigma) uniformity for line and plane sources, respectively. Based on this quantitative study, we demonstrated on-line gamma imaging during proton irradiation. Through these studies, we show that the Compton camera is suitable for future use as an on-line monitor for particle therapy.
引用
收藏
页数:16
相关论文
共 20 条
  • [1] Application of spherical harmonics to image reconstruction for the Compton camera
    Basko, R
    Zeng, GSL
    Gullberg, GT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 887 - 894
  • [2] Improving image reconstruction for Compton camera based imaging for proton radiotherapy verification
    Draeger, E.
    Peterson, S.
    Mackin, D.
    Beddar, S.
    Polf, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S273 - S273
  • [3] In vivo verification of particle therapy: how Compton camera configurations affect 3D image quality
    Mackin, D.
    Draeger, E.
    Peterson, S.
    Polf, J.
    Beddar, S.
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [4] Secondary Particle Interactions in a Compton Camera Designed for in Vivo Range Verification of Proton Therapy
    Panthi, R.
    Maggi, P.
    Peterson, S.
    Mackin, D.
    Polf, J.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E269 - E269
  • [5] Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy
    Panthi, Rajesh
    Maggi, Paul
    Peterson, Stephen
    Mackin, Dennis
    Polf, Jerimy
    Beddar, Sam
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (03) : 383 - 391
  • [6] Optimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy
    Lee, Chae Young
    Song, Hankyeol
    Park, Chan Woo
    Chung, Yong Hyun
    Kim, Jin Sung
    Park, Justin C.
    [J]. PLOS ONE, 2016, 11 (05):
  • [7] Design Study of the Absorber Detector of a Compton Camera for On-line Control in Ion Beam Therapy
    Richard, M. -H.
    Dahoumane, M.
    Dauvergne, D.
    Dedes, G.
    De Rydt, M.
    Freud, N.
    Letang, J. M.
    Lojacono, X.
    Krimmer, J.
    Maxim, V.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Walenta, A. H.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3496 - 3500
  • [8] Design Study of the Absorber Detector of a Compton Camera for On-Line Control in Ion Beam Therapy
    Richard, M. -H.
    Dahoumane, M.
    Dauvergne, D.
    De Rydt, M.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Lojacono, X.
    Maxim, V.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Walenta, A. H.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1850 - 1855
  • [9] Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification
    Gutierrez, A.
    Baker, C.
    Boston, H.
    Chung, S.
    Judson, D. S.
    Kacperek, A.
    Le Crom, B.
    Moss, R.
    Royle, G.
    Speller, R.
    Boston, A. J.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [10] Image reconstruction for Compton camera applied to 3D prompt γ imaging during ion beam therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ray, Cedric
    Dauvergne, Denis
    Testa, Etienne
    Freud, Nicolas
    Letang, Jean Michel
    Maxim, Voichita
    Prost, Remy
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3518 - 3521