New UV spectral responsivity scale of the PTB based on a cryogenic radiometer and an argon plasma arc radiation source

被引:19
|
作者
Meindl, P. [1 ]
Klinkmueller, A. E. [1 ]
Werner, L. [1 ]
Johannsen, U. [1 ]
Gruetzmacher, K. [1 ]
机构
[1] Phys Tech Bundesanstalt, Inst Berlin, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/43/2/S15
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryogenic-radiometer-based calibration facility utilizing monochromatized radiation of an argon arc plasma has been put into operation at the PTB. The high radiance of the plasma Source allows us to improve the accuracy of the UV spectral responsivity scale between 200 nm and 410 nm and to achieve relative standard uncertainties of about 0.1% to 0.2%. Comparison with the PTB laser-based cryogenic radiometer at five laser lines in the UV indicated excellent agreement.
引用
收藏
页码:S72 / S77
页数:6
相关论文
共 36 条
  • [21] MEASUREMENT OF ARGON TRANSITION PROBABILITIES USING THE THERMAL ARC PLASMA AS A RADIATION SOURCE
    OLSEN, HN
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1963, 3 (01): : 59 - 76
  • [22] Measurement of the absolute spectral responsivity in the mid-infrared based on the cryogenic electrical substitution radiometer and an optimized thermopile detector
    Pohl, Tobias
    Meindl, Peter
    Johannsen, Uwe
    Taubert, Dieter
    Werner, Lutz
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2019, 8 (01) : 195 - 205
  • [23] PTB's radiometric scales for UV and VUV source calibration based on synchrotron radiation
    Klein, Roman
    Kroth, Simone
    Paustian, Wolfgang
    Richter, Mathias
    Thornagel, Reiner
    METROLOGIA, 2018, 55 (03) : 386 - 391
  • [24] Monochromatic Radiation Source Based on a Supercontinuum Laser for Measurement of Spectral Sensitivity of Radiation Detectors in the Range 0.9–1.6 μm with the Use of an Absolute Cryogenic Radiometer
    A. Yu. Dunaev
    A. S. Baturin
    V. N. Krutikov
    S. P. Morozova
    Measurement Techniques, 2021, 63 : 877 - 882
  • [25] Monochromatic Radiation Source Based on a Supercontinuum Laser for Measurement of Spectral Sensitivity of Radiation Detectors in the Range 0.9-1.6 μm with the Use of an Absolute Cryogenic Radiometer
    Dunaev, A. Yu
    Baturin, A. S.
    Krutikov, V. N.
    Morozova, S. P.
    MEASUREMENT TECHNIQUES, 2021, 63 (11) : 877 - 882
  • [26] Realization of a spectral radiance responsivity scale with a laser-based source and Si radiance meters
    Eppeldauer, GP
    Brown, SW
    Larason, TC
    Rácz, M
    Lykke, KR
    METROLOGIA, 2000, 37 (05) : 531 - 534
  • [27] Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer
    Werner, L
    Fischer, J
    Johannsen, U
    Hartmann, J
    METROLOGIA, 2000, 37 (04) : 279 - 284
  • [28] Diagnostics of helium-argon arc discharge plasma based on spectral line shape measurements
    Wujec, T
    Musielok, J
    ACTA PHYSICA POLONICA A, 1999, 95 (02) : 221 - 230
  • [29] Gas Discharge Point Source of UV Radiation Based on Argon–Copper Gas–Vapor Mixture
    A. K. Shuaibov
    R. V. Gritsak
    A. I. Minya
    Z. T. Gomoki
    A. A. Malinina
    A. N. Malinin
    M. I. Vatrala
    Surface Engineering and Applied Electrochemistry, 2023, 59 : 362 - 367
  • [30] SPECTRAL STUDY OF TEMPERATURE DISTRIBUTION IN CHANNEL OF AN ELECTRIC-ARC ARGON-PLASMA SOURCE WITH AXIAL FLOW OF WORKING BODY
    PUSTOGAR.AV
    YAKOVLEV, EA
    HIGH TEMPERATURE, 1967, 5 (04) : 637 - &