New UV spectral responsivity scale of the PTB based on a cryogenic radiometer and an argon plasma arc radiation source

被引:19
|
作者
Meindl, P. [1 ]
Klinkmueller, A. E. [1 ]
Werner, L. [1 ]
Johannsen, U. [1 ]
Gruetzmacher, K. [1 ]
机构
[1] Phys Tech Bundesanstalt, Inst Berlin, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/43/2/S15
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryogenic-radiometer-based calibration facility utilizing monochromatized radiation of an argon arc plasma has been put into operation at the PTB. The high radiance of the plasma Source allows us to improve the accuracy of the UV spectral responsivity scale between 200 nm and 410 nm and to achieve relative standard uncertainties of about 0.1% to 0.2%. Comparison with the PTB laser-based cryogenic radiometer at five laser lines in the UV indicated excellent agreement.
引用
收藏
页码:S72 / S77
页数:6
相关论文
共 36 条
  • [31] UV Radiation Source Based on the Plasma of a Glow Discharge in a Mixture of Helium with Water Vapors
    Uzhgorod National University, 46 Pidgirna Str., Uzhgorod
    88000, Ukraine
    Journal of Applied Spectroscopy, 2001, 68 (04) : 715 - 718
  • [32] Investigation of the Characteristics of a Pulsed UV Radiation Source Based on an Unlimited Short-Arc Discharge in Xenon
    Gavrish, S. V.
    Kireev, S. G.
    Potapenko, A. O.
    Shashkovsky, S. G.
    PLASMA PHYSICS REPORTS, 2024, 50 (05) : 662 - 666
  • [33] Gas Discharge Point Source of UV Radiation Based on Argon-Copper Gas-Vapor Mixture
    Shuaibov, A. K.
    Gritsak, R. V.
    Minya, A. I.
    Gomoki, Z. T.
    Malinina, A. A.
    Malinin, A. N.
    Vatrala, M. I.
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2023, 59 (03) : 362 - 367
  • [34] UV radiation source based on a copper vapour laser with acousto-optically controlled spectral and temporal parameters
    Gradoboev, YG
    Gulyaev, YV
    Kazaryan, MA
    Kruzhalov, SV
    Lyabin, NA
    Mokrushin, YM
    Shakin, OV
    QUANTUM ELECTRONICS, 2004, 34 (12) : 1133 - 1137
  • [35] Spectral responsivity calibration of the reference radiation thermometer at KRISS by using a super-continuum laser-based high-accuracy monochromatic source
    Yoo, Yong Shim
    Kim, Gun Jung
    Park, Seongchong
    Lee, Dong-Hoon
    Kim, Bong-Hak
    METROLOGIA, 2016, 53 (06) : 1354 - 1364
  • [36] Definition of a new level one test case -: Measurements of equilibrium radiation from an inductively coupled plasma in the near-UV to near-IR spectral region for a Martian-type CO2-N2 mixture
    Vacher, D
    Faure, G
    da Silva, ML
    Dudeck, M
    André, P
    International Workshop on Radiation of High Temperature Gases in Atmospheric Entry, Pt 2, Proceedings, 2005, 583 : 99 - 104