New UV spectral responsivity scale of the PTB based on a cryogenic radiometer and an argon plasma arc radiation source

被引:19
|
作者
Meindl, P. [1 ]
Klinkmueller, A. E. [1 ]
Werner, L. [1 ]
Johannsen, U. [1 ]
Gruetzmacher, K. [1 ]
机构
[1] Phys Tech Bundesanstalt, Inst Berlin, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/43/2/S15
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryogenic-radiometer-based calibration facility utilizing monochromatized radiation of an argon arc plasma has been put into operation at the PTB. The high radiance of the plasma Source allows us to improve the accuracy of the UV spectral responsivity scale between 200 nm and 410 nm and to achieve relative standard uncertainties of about 0.1% to 0.2%. Comparison with the PTB laser-based cryogenic radiometer at five laser lines in the UV indicated excellent agreement.
引用
收藏
页码:S72 / S77
页数:6
相关论文
共 36 条
  • [11] Mid-infrared spectral responsivity scale based on an absolute cryogenic radiometer and a tunable quantum cascade laser
    Liu, Wende
    Xu, Nan
    He, Yingwei
    Gan, Haiyong
    Feng, Guojin
    Wang, Yanfei
    Liu, Xiangliang
    Fu, Yangting
    Wang, Yingce
    Lin, Yandong
    METROLOGIA, 2021, 58 (02)
  • [12] Long-Wave Infrared Absolute Spectral Responsivity Scale by Using an Absolute Cryogenic Radiometer
    Liu Hong-bo
    Shi Xue-shun
    Xu Wen-bin
    Liu Chang-ming
    Liu Hong-yuani
    Wang Heng-fei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (12) : 3680 - 3685
  • [13] Spectral responsivity calibration of silicon photodetectors using monochromator-based cryogenic radiometer
    Xu, Nan
    Lin, Yandong
    Gan, Haiyong
    Li, Jianwei
    OPTICAL MEASUREMENT TECHNOLOGY AND INSTRUMENTATION, 2016, 10155
  • [14] Mid-infrared absolute spectral responsivity scale based on an absolute cryogenic radiometer and an optical parametric oscillator laser
    Zhao, Kun
    Shi, Xueshun
    Chen, Haidong
    Liu, Yulong
    Liu, Changming
    Chen, Kunfeng
    Li, Ligong
    Gan, Haiyong
    Ma, Chong
    METROLOGIA, 2016, 53 (03) : 981 - 985
  • [15] A Cryogenic Radiometry Based Spectral Responsivity Scale at the National Metrology Centre
    Xu, Gan
    Huang, Xuebo
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN 2011), 2011, 19
  • [16] A New Spectral Responsivity Calibration Comparator of InGaAs photodiode Based on Cryogenic Radiometer Fundamental at the National Institute of Metrology of China
    He, Yingwei
    Gan, Haiyong
    Liu, Wende
    Lin, Yongjie
    Wang, Yangyang
    Xu, Ning
    Zhao, Weidiang
    Liu, Zhiwei
    Xiong, Limin
    Xu, Nan
    Lin, Yandong
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VII, 2020, 11552
  • [17] New setup for the absolute spectral responsivity of radiation thermometers with a supercontinuum source
    National Institute of Advanced Industrial Science and Technology, NMIJ, Tukuba, Japan
    IMEKO World Congr., (821-823):
  • [18] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Çelikel, O
    Bazkir, Ö
    Küçükoglu, M
    Samedov, F
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (06) : 529 - 543
  • [19] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Oğuz Çelikel
    Özcan Bazkir
    Mehmet Küçükoğlu
    Farhad Samedov
    Optical and Quantum Electronics, 2005, 37 : 529 - 543
  • [20] Total and spectral radiance measurements of blackbody radiation sources based on an absolute cryogenic radiometer
    Gan, Haiyong
    Xu, Nan
    Liu, Xiangliang
    He, Yingwei
    Wu, Houping
    Feng, Guojin
    Liu, Wende
    Lin, Yandong
    AOPC 2019: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2019, 11338