Realization of a spectral radiance responsivity scale with a laser-based source and Si radiance meters

被引:15
|
作者
Eppeldauer, GP [1 ]
Brown, SW [1 ]
Larason, TC [1 ]
Rácz, M [1 ]
Lykke, KR [1 ]
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1088/0026-1394/37/5/41
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A spectral radiance responsivity (SRR) scale derived from the spectral irradiance responsivity scale has been realized on the newly developed NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources (SIRCUS). The scales were directly derived from the primary standard cryogenic radiometer using transfer standard irradiance trap detectors and laser-based uniform sources. Silicon radiance meters of standards quality have been developed to hold the SRR scale. The radiance meters were characterized and optimized fur size-of-source effects. The optimized meters were calibrated for SRR against the monochromatic uniform source. In addition to the SIRCUS calibrations, preliminary tests were also made on the Spectral Comparator Facility (SCF) of the NIST. These relative SRR tests were made in both imaging and non-imaging measurement modes. The results of the different SRR calibrations are compared and evaluated.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 50 条
  • [1] Realization of the Radiance Scale Using Transfer Function of the Laser-Based Optical System
    Kilin, M.
    Tutunculer, H.
    Bazkir, O.
    Meric, S.
    INTERNATIONAL JOURNAL OF OPTICS, 2020, 2020
  • [2] Realization of a spectral radiance scale at KRISS
    Park, Seung Nam
    Seo, Jung Chul
    Shin, Dong Joo
    Lee, In Won
    Metrologia, 2003, 40 (1 SPEC.)
  • [3] Realization of a spectral radiance scale at KRISS
    Park, SN
    Seo, JC
    Shin, DJ
    Lee, IW
    METROLOGIA, 2003, 40 (01) : S196 - S199
  • [4] UNCERTAINTY ANALYSIS OF SPECTRAL RADIANCE SCALE REALIZATION
    Dai Cai-hong
    Wu Zhi-feng
    Wang Yan-fei
    Li Ling
    AOPC 2017: OPTICAL SENSING AND IMAGING TECHNOLOGY AND APPLICATIONS, 2017, 10462
  • [5] Reduction of speckle effect using galvanometer scanners in a laser-based uniform source for radiance responsivity measurement
    Liu, Zhiwei
    Zhao, Weiqiang
    Gan, Haiyong
    Zuo, Hongzhi
    Liu, Wende
    Liu, Xiangliang
    Fan, Qiming
    Lin, Yandong
    Xu, Nan
    MEASUREMENT, 2025, 242
  • [6] Realization of the new national primary scale of spectral radiance and spectral irradiance
    Dai Cai-hong
    Wu Zhi-feng
    Yu Jia-lin
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SPECTROMETER TECHNOLOGIES AND APPLICATIONS, 2013, 8910
  • [7] Spectral radiance source based on supercontinuum laser and wavelength tunable bandpass filter: the spectrally tunable absolute irradiance and radiance source
    Levick, Andrew P.
    Greenwell, Claire L.
    Ireland, Jane
    Woolliams, Emma R.
    Goodman, Teresa M.
    Bialek, Agnieszka
    Fox, Nigel P.
    APPLIED OPTICS, 2014, 53 (16) : 3508 - 3519
  • [8] Absolute Radiance Responsivity Calibration Based on Supercontinuum Laser and Monochromator
    Xie Chenyu
    Zhai Wenchao
    Li Jianjun
    Gao Fang
    Li Yue
    Wu Haoyu
    Zheng Xiaobing
    ACTA OPTICA SINICA, 2019, 39 (07)
  • [9] Absolute Radiance Responsivity Calibration Based on Supercontinuum Laser and Monochromator
    Xie C.
    Zhai W.
    Li J.
    Gao F.
    Li Y.
    Wu H.
    Zheng X.
    Guangxue Xuebao/Acta Optica Sinica, 2019, 39 (07):
  • [10] THE NBS SCALE OF SPECTRAL RADIANCE
    WALKER, JH
    SAUNDERS, RD
    HATTENBURG, AT
    METROLOGIA, 1987, 24 (02) : 79 - 88