Realization of a spectral radiance responsivity scale with a laser-based source and Si radiance meters

被引:15
|
作者
Eppeldauer, GP [1 ]
Brown, SW [1 ]
Larason, TC [1 ]
Rácz, M [1 ]
Lykke, KR [1 ]
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1088/0026-1394/37/5/41
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A spectral radiance responsivity (SRR) scale derived from the spectral irradiance responsivity scale has been realized on the newly developed NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources (SIRCUS). The scales were directly derived from the primary standard cryogenic radiometer using transfer standard irradiance trap detectors and laser-based uniform sources. Silicon radiance meters of standards quality have been developed to hold the SRR scale. The radiance meters were characterized and optimized fur size-of-source effects. The optimized meters were calibrated for SRR against the monochromatic uniform source. In addition to the SIRCUS calibrations, preliminary tests were also made on the Spectral Comparator Facility (SCF) of the NIST. These relative SRR tests were made in both imaging and non-imaging measurement modes. The results of the different SRR calibrations are compared and evaluated.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 50 条
  • [21] Spectral radiance and temporal stability of a uniform radiance source integrating sphere with enhanced blue performance
    D'Amato, D
    ILLUMINATION AND SOURCE ENGINEERING, 1998, 3428 : 2 - 8
  • [22] Spectrally adjustable quasi-monochromatic radiance source based on LEDs and its application for measuring spectral responsivity of a luminance meter
    Hirvonen, Juha-Matti
    Poikonen, Tuomas
    Vaskuri, Anna
    Karha, Petri
    Ikonen, Erkki
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (11)
  • [23] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Kee-Suk Hong
    Seongchong Park
    Seung-Kwan Kim
    Seung-Nam Park
    Dong-Hoon Lee
    Journal of the Korean Physical Society, 2015, 67 : 2045 - 2058
  • [24] Realization of the spectral responsivity scale based on an absolute cryogenic radiometer
    Hong, Kee-Suk
    Park, Seongchong
    Kim, Seung-Kwan
    Park, Seung-Nam
    Lee, Dong-Hoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (12) : 2045 - 2058
  • [25] A HIGH SPECTRAL-RADIANCE NEODYMIUM GLASS LASER
    MAGNANTE, PC
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1968, QE 4 (05) : 363 - &
  • [26] Infrared spectral responsivity scale realization and validations
    Eppeldauer, George P.
    Podobedov, Vyacheslav B.
    APPLIED OPTICS, 2012, 51 (25) : 6003 - 6008
  • [27] SPECTRAL RADIANCE CHARACTERIZATION AND REALIZATION BASED ON HIGH TEMPERATURE BLACKBODY BB3500M
    Dai Cai-hong
    Wu Zhi-feng
    Wang Yan-fei
    SELECTED PAPERS OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE CONFERENCES, 2015, 9795
  • [28] Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ
    Keawprasert, T.
    Yamada, Y.
    Ishii, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (2-3) : 315 - 326
  • [29] SPECTRAL RADIANCE OF A LARGE-AREA INTEGRATING SPHERE SOURCE
    WALKER, JH
    THOMPSON, A
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1995, 100 (01) : 37 - 41
  • [30] Primary Radiometry for the mise-en-pratique: The Laser-Based Radiance Method Applied to a Pyrometer
    Briaudeau, S.
    Sadli, M.
    Bourson, F.
    Rougi, B.
    Rihan, A.
    Zondy, J-J
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2183 - 2196