Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ

被引:4
|
作者
Keawprasert, T. [1 ]
Yamada, Y. [2 ]
Ishii, J. [2 ]
机构
[1] Natl Inst Metrol Thailand, Pathum Thani, Thailand
[2] AIST, Natl Metrol Inst Japan, Tsukuba, Ibaraki, Japan
关键词
ITS-90; realization; Pilot bilateral comparison; Radiance temperature scale; Radiation thermometer; Spectral responsivity measurement;
D O I
10.1007/s10765-014-1782-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
A pilot comparison of radiance temperature scale realizations between the National Institute of Metrology Thailand (NIMT) and the National Metrology Institute of Japan (NMIJ) was conducted. At the two national metrology institutes (NMIs), a 900 nm radiation thermometer, used as the transfer artifact, was calibrated by a means of a multiple fixed-point method using the fixed-point blackbody of Zn, Al, Ag, and Cu points, and by means of relative spectral responsivity measurements according to the International Temperature Scale of 1990 (ITS-90) definition. The Sakuma-Hattori equation is used for interpolating the radiance temperature scale between the four fixed points and also for extrapolating the ITS-90 temperature scale to 2000 C. This paper compares the calibration results in terms of fixed-point measurements, relative spectral responsivity, and finally the radiance temperature scale. Good agreement for the fixed-point measurements was found in case a correction for the change of the internal temperature of the artifact was applied using the temperature coefficient measured at the NMIJ. For the realized radiance temperature range from 400 C to 1100 C, the resulting scale differences between the two NMIs are well within the combined scale comparison uncertainty of 0.12 C (). The resulting spectral responsivity measured at the NIMT has a comparable curve to that measured at the NMIJ especially in the out-of-band region, yielding a ITS-90 scale difference within 1.0 C from the Cu point to 2000 C, whereas the realization comparison uncertainty of NIMT and NMIJ combined is 1.2 C () at 2000 C.
引用
收藏
页码:315 / 326
页数:12
相关论文
共 50 条
  • [1] Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ
    T. Keawprasert
    Y. Yamada
    J. Ishii
    [J]. International Journal of Thermophysics, 2015, 36 : 315 - 326
  • [2] Bilateral Comparison of Blackbodies for Clinical Infrared Ear Thermometers between NIMT and NMIJ
    Manoi, A.
    Norranim, U.
    Kaneko, Y.
    Ishii, J.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 485 - 492
  • [3] Bilateral Comparison of Blackbodies for Clinical Infrared Ear Thermometers between NIMT and NMIJ
    A. Manoi
    U. Norranim
    Y. Kaneko
    J. Ishii
    [J]. International Journal of Thermophysics, 2014, 35 : 485 - 492
  • [4] Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from 232 °C to 1085 °C
    Martin, M. J.
    Knazovicka, L.
    del Campo, D.
    Strnad, R.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 475 - 484
  • [5] Bilateral Comparison on 0.9 m Radiation Temperature Scale between NIMT and Puslit KIM-LIPI
    Keawprasert, Thada
    Rifai, Iip Ahmad
    Yamada, Yoshiro
    Yamaguchi, Yu
    [J]. 2015 54TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2015, : 112 - 115
  • [6] Realization of the 3He vapour-pressure temperature scale at NMIJ/AIST
    Shimazaki, T
    Tamura, O
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 119 - 124
  • [7] Realization of a spectral radiance scale at KRISS
    Park, Seung Nam
    Seo, Jung Chul
    Shin, Dong Joo
    Lee, In Won
    [J]. Metrologia, 2003, 40 (1 SPEC.)
  • [8] Realization of a spectral radiance scale at KRISS
    Park, SN
    Seo, JC
    Shin, DJ
    Lee, IW
    [J]. METROLOGIA, 2003, 40 (01) : S196 - S199
  • [9] Design and characterization of Si and InGaAs pyrometers for radiance temperature scale realization between 232°C and 962°C
    Noorma, M.
    Mekhontsev, S.
    Khromchenko, V.
    Gura, A.
    Litorja, M.
    Tsai, B.
    Hanssen, L.
    [J]. THERMOSENSE XXVIII, 2006, 6205
  • [10] Comparison of temperature scale maintained on platinum resistance thermometers with the NPL radiance temperature scale
    McEvoy, HC
    Chattle, MV
    Butler, J
    [J]. METROLOGIA, 1996, 33 (04) : 353 - 362