Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from 232 °C to 1085 °C

被引:0
|
作者
Martin, M. J. [1 ]
Knazovicka, L. [2 ]
del Campo, D. [1 ]
Strnad, R. [2 ]
机构
[1] Ctr Espanol Metrol, Tres Cantos, Spain
[2] Czech Metrol Inst, Brno, Czech Republic
关键词
Bilateral comparison; Radiance temperature scale; Standard radiation thermometer;
D O I
10.1007/s10765-014-1576-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
A bilateral comparison between the Centro Espaol de Metrologia (CEM) and the eskA1/2 MetrologickA1/2 Institut (CMI) of radiance temperature scale realizations in the range from to was carried out during 2012 to support the calibration measurements capabilities of CMI in radiation thermometry. The CEM capabilities were demonstrated previously in a recent comparison of European laboratories over the range from to . A CMI KE-LP5 radiation thermometer, working at 1568 nm, was used as a traveling standard. CEM measurements were done at the fixed-points (FPs) of Zn, Ag, and Cu and, for the rest of the temperatures, variable temperature blackbodies (VTBBs) were used. CMI measurements were done at the FPs of Sn, Al, and Cu, and the rest of the temperatures were measured with VTBBs. The size-of-source effect was measured at CEM to decide whether or not the measurements from both laboratories should be corrected by this effect (when the diameter of the sources was different at each laboratory). CMI performed the measurement of the Al FP before and after CEM to evaluate the stability of the radiation thermometer. The results for both laboratories are summarized, and they agree within their expanded uncertainties.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [1] Design and characterization of Si and InGaAs pyrometers for radiance temperature scale realization between 232°C and 962°C
    Noorma, M.
    Mekhontsev, S.
    Khromchenko, V.
    Gura, A.
    Litorja, M.
    Tsai, B.
    Hanssen, L.
    [J]. THERMOSENSE XXVIII, 2006, 6205
  • [2] Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ
    Keawprasert, T.
    Yamada, Y.
    Ishii, J.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (2-3) : 315 - 326
  • [3] Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ
    T. Keawprasert
    Y. Yamada
    J. Ishii
    [J]. International Journal of Thermophysics, 2015, 36 : 315 - 326
  • [5] Realization of ITS-90 Radiance Temperature Scale from 961.78 °C to 3000 °C at CSIR-NPL
    Pant, U.
    Gupta, G.
    Meena, H.
    Bhatt, A.
    Bapna, K.
    Shivagan, D. D.
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (01): : 3 - 13
  • [6] Realization of ITS-90 Radiance Temperature Scale from 961.78 °C to 3000 °C at CSIR-NPL
    Umesh Pant
    Gaurav Gupta
    Hansraj Meena
    Ashish Bhatt
    Komal Bapna
    D. D. Shivagan
    [J]. MAPAN, 2022, 37 : 3 - 13
  • [7] EURAMET Project to Examine Underlying Parameters in Radiance Temperature Scale Realization, 156 °C to 1000 °C
    McEvoy, H. C.
    Martin, M. J.
    Steiner, A.
    Schreiber, E.
    Girard, F.
    Battuello, M.
    Sadli, M.
    Ridoux, P.
    Gutschwager, B.
    Hollandt, J.
    Diril, A.
    Pehlivan, O.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 446 - 466
  • [8] Realization of a radiation temperature scale from 0 °C to 232 °C by a thermal infrared thermometer based on a multiple-fixed-point technique
    Yoo, Yong Shim
    Kim, Bong-Hak
    Lim, Sun Do
    Park, Seung-Nam
    Park, Seongchong
    [J]. METROLOGIA, 2013, 50 (04) : 409 - 416
  • [10] INTERLABORATORY COMPARISON OF DIGITAL THERMOMETER BETWEEN THE TEMPERATURE RANGE FROM-40 °C TO 420 °C
    Dogan, Aliye Kartal
    Uytun, Ali
    Kalemci, Murat
    Ozdemir, Kursat
    [J]. XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1585 - 1588