Realization of ITS-90 Radiance Temperature Scale from 961.78 °C to 3000 °C at CSIR-NPL

被引:1
|
作者
Pant, U. [1 ,2 ]
Gupta, G. [1 ]
Meena, H. [1 ]
Bhatt, A. [1 ,2 ]
Bapna, K. [1 ,2 ]
Shivagan, D. D. [1 ,2 ]
机构
[1] CSIR Natl Phys Lab, Dr KS Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
关键词
Radiation thermometer; Sakuma-Hattori equation; Blackbody fixed points; Metal-carbon eutectics; RADIATION THERMOMETER; FIXED-POINT; INFRARED THERMOMETER; UNCERTAINTY; RADIOMETRY; COPPER;
D O I
10.1007/s12647-021-00507-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The traceable temperature measurements using the radiation thermometers and thermal imagers above 1000 degrees C require blackbody fixed points and extrapolation or interpolation of Planck's radiation law. For the realization of the ITS-90 radiance temperature scale, a radiation thermometer needs to be calibrated by using the pure metal fixed-point blackbodies (Ag or Au or Cu) and Planck's radiation law in ratio form. At CSIR-NPL, the high-temperature radiance scale above the silver fixed-point is realized using a silicon photodiode detector-based linear pyrometer (LP4) with a 650 nm nominal wavelength. This paper presents the realization of high-temperature blackbodies of Ag (961.78 degrees C) and Cu (1084.62 degrees C), and a detailed investigation of their melting and freezing plateaus measured using LP4. The mean effective wavelength of the LP4 was evaluated using Wien's approximation to Ag and Cu photocurrent outputs, computed to be 650.09 nm, and used in Planck's equation to determine T-90 temperatures. The characteristics of these blackbody sources and radiation thermometer, such as size-of-source effect (SSE) and distance effect (DE) were measured, and their contributions in measurement uncertainty were evaluated. Expanded uncertainties of fixed-point realization for Ag and Cu are estimated as 0.25 and 0.30 degrees C (k = 2), respectively. Further, photocurrents calculated using Ag fixed-point blackbody for corresponding temperatures by ratio method were employed to solve the coefficients of the Sukuma-Hattori equation for extrapolation of temperatures and measurement uncertainties up to 3000 degrees C. The uncertainty of scale realization is estimated to be 3.72 degrees C (k = 2) at 3000 degrees C.
引用
收藏
页码:3 / 13
页数:11
相关论文
共 32 条
  • [1] Realization of ITS-90 Radiance Temperature Scale from 961.78 °C to 3000 °C at CSIR-NPL
    Umesh Pant
    Gaurav Gupta
    Hansraj Meena
    Ashish Bhatt
    Komal Bapna
    D. D. Shivagan
    [J]. MAPAN, 2022, 37 : 3 - 13
  • [2] Development and Realization of Fe–C and Co–C Eutectic Fixed-Point Blackbodies for Radiation Thermometry at CSIR-NPL
    Umesh Pant
    Hansraj Meena
    Gaurav Gupta
    Komal Bapna
    D. D. Shivagan
    [J]. International Journal of Thermophysics, 2020, 41
  • [3] New interpolating equations of ITS-90 for SPRTs and HTSPRTs for the temperature range 419.527°C-961.78°C
    Sun, J. P.
    Li, T.
    Hao, X.
    Pan, J.
    Zeng, J.
    [J]. METROLOGIA, 2020, 57 (04)
  • [4] Development and Realization of Fe-C and Co-C Eutectic Fixed-Point Blackbodies for Radiation Thermometry at CSIR-NPL
    Pant, Umesh
    Meena, Hansraj
    Gupta, Gaurav
    Bapna, Komal
    Shivagan, D. D.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2020, 41 (07)
  • [5] Intercomparison of the realization of the ITS-90 in the temperature range -40°C to 420°C between CENAM and PTB
    Noatsch, U
    Tegeler, E
    Méndez-Lango, E
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 855 - 859
  • [6] Realisation of the ITS-90 and thermodynamic temperature measurements above 960 °C using a monochromator-based radiance comparator
    Bourson, F.
    Briaudeau, S.
    Sadli, M.
    Rougie, B.
    Kozlova, O.
    [J]. METROLOGIA, 2022, 59 (01)
  • [7] Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from 232 °C to 1085 °C
    Martin, M. J.
    Knazovicka, L.
    del Campo, D.
    Strnad, R.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 475 - 484
  • [8] Bilateral ITS-90 Comparison at WC-C Peritectic Fixed Point Between NIM and NPL
    Dong, W.
    Lowe, D. H.
    Lu, X.
    Machin, G.
    Yuan, Z.
    Wang, T.
    Bloembergen, P.
    Xiao, C.
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 786 - 790
  • [9] Approximation of the ITS-90 with high temperature thermometers up to 1085 °C
    Moiseeva, NP
    Pokhodun, AI
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 369 - 374
  • [10] Investigation of the accuracy of the ITS-90 with reference to thermodynamic temperature in the range from 400°C up to 600°C
    Taubert, DR
    Hartmann, J
    Hollandt, J
    Fischer, J
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 7 - 12