Device Motion Indication: A Novel Image-Based Tool to Measure Relative Device Motion During Coronary Intervention

被引:0
|
作者
Abu Fanne, Rami [1 ]
Meisel, Simcha Ron [1 ]
Shotan, Avraham [1 ]
Frimerman, Aharon [1 ]
机构
[1] Technion Israel Inst Technol, Rappaport Fac Med, Hillel Yaffe Med Ctr, Haifa, Israel
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2017年 / 29卷 / 12期
关键词
geographical miss; stent deployment; thrombosis; restenosis; ANGIOGRAPHY; ARTERIES; VELOCITY; CT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Movement of the stent delivery system in the coronary bed as a result of the cardiac cycle is a well-known clinical observation that usually is either underestimated or ignored. This effect may potentially jeopardize precise stent deployment. We used a novel technology to objectively measure the relative intracoronary device motion in the different coronary segments throughout the cardiac cycle. Methods. A total of 193 patients undergoing coronary angiography were enrolled and their studies were analyzed for device movement using the SyncVision System (Philips Volcano). The SyncVision System is an add-on image-processing system with unique enhancement and stabilization capabilities. A new feature, the device-motion indication, can precisely display the predeployment device movement measurement (DMM). The device movements within the three segments of each coronary artery were recorded. Results. We identified 218 branch point sites. Median axial displacement was 2.97 mm at the right coronary artery (RCA), 2.22 mm at the left circumflex, and 1.84 mm at the left anterior descending segments. The most movable segments were mid and distal RCA (P<. 05). Both heart rate and cardiac contractility significantly affected DMM. Conclusions. The study demonstrates an innovative feature of the SyncVision System as a tool to precisely measure relative device displacement. We claim that the relative device movement is an important quality metric to consider for achieving an effective stent implantation process.
引用
收藏
页码:421 / 424
页数:4
相关论文
共 50 条
  • [1] A novel image-based motion correction algorithm on ultrasonic image
    Wang, Xuan
    Li, Yaqin
    Li, Shigao
    MIPPR 2015: PARALLEL PROCESSING OF IMAGES AND OPTIMIZATION; AND MEDICAL IMAGING PROCESSING, 2015, 9814
  • [2] Image-Based Respiratory Motion Compensation for Fluoroscopic Coronary Roadmapping
    Zhu, Ying
    Tsin, Yanghai
    Sundar, Hari
    Sauer, Frank
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 287 - 294
  • [3] Angle-independent measure of motion for image-based gating in 3D coronary angiography
    Lehmann, Glen C.
    Holdsworth, David W.
    Drangova, Maria
    MEDICAL PHYSICS, 2006, 33 (05) : 1311 - 1320
  • [4] Image-based Space Object Reconstruction and Relative Motion Estimation using Incremental Structure from Motion
    Zhang, Qimin
    An, Pei
    Wang, Shuquan
    Bai, Xiaoli
    Zhang, Wei
    2018 IEEE CSAA GUIDANCE, NAVIGATION AND CONTROL CONFERENCE (CGNCC), 2018,
  • [5] KRIS: A Novel Device for Kinesthetic Corrective Feedback during Robot Motion
    Verheggen, Jorn
    Baraka, Kim
    2023 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, ICRA, 2023, : 5041 - 5047
  • [6] A novel motion detection pointing device using a binary CMOS image sensor
    Park, Hee Ju
    Kim, Kyung Bum
    Kim, Jeong Hun
    Kim, Suki
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 837 - 840
  • [7] Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography
    Zhang, X.
    Sisniega, A.
    Zbijewski, W.
    Contijoch, F.
    McVeigh, E.
    Stayman, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3885 - 3885
  • [8] Hindfoot motion through helical axis image-based on dynamic CT scan using an original simulated weightbearing device
    Tejero, Sergio
    Fernandez-Marin, Reyes
    Gonzalez-Martin, David
    Vallejo-Marquez, Mercedes
    Paulano-Godino, Felix
    Herrera-Perez, Mario
    FOOT AND ANKLE SURGERY, 2023, 29 (07) : 531 - 537
  • [9] SELF-ASSESSING IMAGE-BASED RESPIRATORY MOTION COMPENSATION FOR FLUOROSCOPIC CORONARY ROADMAPPING
    Manhart, Michael
    Zhu, Ying
    Vitanovski, Dime
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1065 - 1069
  • [10] Development and Intertester Reliability of a Novel Device to Measure Nonweightbearing Ankle Joint Dorsiflexion Range of Motion
    Charles, James A.
    Diot, Romain
    Houari, Camilia
    Chuter, Vivienne
    Pillu, Michel
    Mcdonough, Daniel
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2023, 113 (01)