Dosimetric analysis of intensity-modulated radiation therapy and volumetric-modulated arc therapy in comparison with conventional box technique in the treatment of carcinoma cervix: An impact of prosthetic implant

被引:1
|
作者
Bhushan, Manindra [1 ,2 ]
Tripathi, Deepak [2 ]
Yadav, Girigesh [1 ]
Kumar, Lalit [1 ,3 ]
Chowdhary, Rahul Lal [1 ]
Pahuja, Anjali K. [1 ]
Suhail, Mahamood [1 ]
Mitra, Swarupa [1 ]
Gairola, Munish [1 ]
机构
[1] Rajiv Gandhi Canc Inst & Res Ctr, Div Med Phys, Dept Radiat Oncol, New Delhi, India
[2] Amity Univ, Amity Sch Appl Sci, Dept Phys, Noida, Uttar Pradesh, India
[3] Dr APJ Abdul Kalam Tech Univ, Dept Appl Sci & Human, Lucknow, Uttar Pradesh, India
关键词
High-density implant; intensity-modulated radiation therapy; prosthesis; radiotherapy; volumetric-modulated arc therapy; METALLIC HIP PROSTHESES; PHOTON-BEAM ENERGY; PROSTATE-CANCER; PLAN QUALITY; RADIOTHERAPY; IRRADIATION; RAPIDARC; NUMBER; TISSUE; IMRT;
D O I
10.4103/jcrt.JCRT_835_20
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The number of patients for carcinoma cervix with implanted hip prostheses has been increasing worldwide during the past several decades. Technological advancements are useful for delivering higher doses, i.e., dose escalation to the target, but the presence of high-density implanted hip prosthesis creates challenges for the planner. Materials and Methods: A population of 25 patients was selected for the study. Plans were generated using the MONACO treatment planning system keeping the isocenter same. The parameters evaluated for planning target volume (PTV) were D-98%, D-50%, D-2%, D-max, D-mean, V-107%, and V-110%. Similarly, the parameters D-max, D-mean, and D-2cc were evaluated for the delineated critical organs. Average monitor units (TMUmean) were also assessed. Results: D-98% of PTV was 44.51 (standard deviation [SD]: 0.13) Gy, 44.41 (SD: 0.38) Gy, 44.58 (SD: 0.14) Gy, 44.08 (SD: 0.41) Gy and 44.46 (SD: 0.32) Gy for 4F, intensity-modulated radiation therapy (IMRT), IMRT_WP, volumetric-modulated arc therapy (VMAT), and VMAT_WP techniques, respectively, where WP stands for "without prosthesis". Volume of bowel receiving 45 Gy was 86.82 (SD: 66.38) cm(3), 6.97 (SD: 5.77) cm(3), 14.11 (SD: 14.29) cm(3), 13.31 (SD: 6.57) cm(3), and 10.31 (SD: 10.94) cm(3) for 4F, IMRT, IMRT_WP, VMAT and VMAT_WP techniques, respectively. Conclusion: VMAT has an edge over other techniques in terms of target coverage and sparing of critical organs in the presence of metallic prosthesis. Information about the geometry and density of prosthesis will be beneficial for treatment planning.
引用
收藏
页码:1504 / 1512
页数:9
相关论文
共 50 条
  • [21] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [22] Dosimetric Comparison of the Newest Version Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy Plans for Angiosarcoma of the Scalp
    Mizuno, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E10 - E10
  • [23] Dosimetric benefits of intensity-modulated radiotherapy and volumetric-modulated arc therapy in the treatment of postoperative cervical cancer patients
    Deng, Xia
    Han, Ce
    Chen, Shan
    Xie, Congying
    Yi, Jinling
    Zhou, Yongqiang
    Zheng, Xiaomin
    Deng, Zhenxiang
    Jin, Xiance
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 25 - 31
  • [24] Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation-A comparison with traditional techniques
    Studenski, Matthew T.
    Shen, Xinglei
    Yu, Yan
    Xiao, Ying
    Shi, Wenyin
    Biswas, Tithi
    Werner-Wasik, Maria
    Harrison, Amy S.
    MEDICAL DOSIMETRY, 2013, 38 (01) : 48 - 54
  • [25] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Hidetaka Arimura
    Ryosuke Asamura
    Taka-aki Hirose
    Saiji Ohga
    Jun-ichi Fukunaga
    Radiological Physics and Technology, 2019, 12 : 137 - 148
  • [26] Comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy prostate cancer plans accounting for cold spots
    Tran Thi Thao Nguyen
    Arimura, Hidetaka
    Asamura, Ryosuke
    Hirose, Taka-aki
    Ohga, Saiji
    Fukunaga, Jun-ichi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (02) : 137 - 148
  • [27] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [28] Dosimetric comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for anal cancer
    Chiang, Bing-Hao
    Hibbitts, Kerry
    Ortega, Heather
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 190 - 192
  • [29] Dosimetric impact of dental metallic crown on intensity-modulated radiotherapy and volumetric-modulated arc therapy for head and neck cancer
    Kamomae, Takeshi
    Itoh, Yoshiyuki
    Okudaira, Kuniyasu
    Nakaya, Takayoshi
    Tomida, Masashi
    Miyake, Yoshikazu
    Oguchi, Hiroshi
    Shiinoki, Takehiro
    Kawamura, Mariko
    Yamamoto, Noriyuki
    Naganawa, Shinji
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 234 - 245
  • [30] Dosimetric comparison of intensity-modulated radiation therapy and volumetric-modulated arc therapy plans for the treatment of glioma using flattening filter-free and flattening filter modes
    Xu, Dandan
    Jia, Fei
    Li, Guowen
    Li, Hongfei
    ONCOLOGY LETTERS, 2017, 13 (05) : 3451 - 3456