Aim: Volumetric modulated arc therapy (VMAT), an extension of intensity modulated radiation therapy (IMRT), employs modifications in gantry rotation speed, machine dose rate and multi-leaf collimator motion to deliver a three-dimensional dose distribution. This study compared VMAT to IMRT for patients with anal carcinoma. Materials and Methods: Sixteen patients previously treated with IMRT were retrospectively selected. Each patient received a total dose of 57 center dot 6-63 center dot 0 Gy in 1 center dot 8 Gy fractions. A single- or double-isocenter multi-arc VMAT treatment plan was generated using Eclipse RapidArc system with the same computed tomography image sets and optimisation constraints used for IMRT. Dose-volume histograms (DVHs) for planning target volumes (PTVs) and organs at risk (OARs), and monitor units (MUs) and beam on times (BOTs) were used for comparison. Results: IMRT and VMAT plans showed insignificant differences in PTV homogeneity and conformity and sparing hips and bowel. VMAT required fewer mean MU and shorter BOT per plan (1,597 MU, 2 center dot 66 min) compared to IMRT (2,571 MU, 4 center dot 29 min) with p < 0 center dot 0001. Conclusions: Fewer MU and shorter BOT for VMAT may decrease the damage from secondary radiation and treatment delivery uncertainty due to intra-fraction tumour motion, leading to higher machine throughput and improving patient comfort, with less treatment time.
引用
收藏
页码:190 / 192
页数:3
相关论文
共 50 条
  • [1] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy vs Intensity Modulated Radiation Therapy for Anal Cancer
    Hibbitts, K.
    Chiang, B.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E623 - E623
  • [2] Comparison of Dosimetric Analysis of Volumetric Modulated Arc Therapy Vs Intensity Modulated Radiation Therapy for Anal Cancer
    Chiang, B.
    Hibbitts, K.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E305 - E305
  • [3] Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer
    Li, Zhiping
    Zeng, Jianshuang
    Wang, Zi
    Zhu, Hong
    Wei, Yuquan
    [J]. ONCOLOGY LETTERS, 2014, 8 (04) : 1427 - 1434
  • [4] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [5] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    [J]. MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [6] A dosimetric comparison of volumetric modulated arc therapy with step-and-shoot intensity modulated radiation therapy for prostate cancer
    Mellon, Eric A.
    Javedan, Khosrow
    Strom, Tobin J.
    Moros, Eduardo G.
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Wasserman, Stu G.
    Wilder, Richard B.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2015, 5 (01) : 11 - 15
  • [7] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [8] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Soft Tissue Sarcoma of the Extremities
    Lawless, Anna K.
    Fangupo, Nonga
    Estoesta, Reuben Patrick
    Perez, Gino
    Alzaidi, Samara
    Heller, Gillian
    Hill, Robin
    Hong, Angela M.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2022, 12 (04) : E306 - E311
  • [9] Dosimetric Comparison of Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy in Craniospinal Radiotherapy of Childhood
    Ozer, Elif Eda
    Coban, Yasin
    Cifter, Fulya
    Karacam, Songul
    Uzel, Omer
    Turkan, Tahir Sedat
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 96 - 103
  • [10] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636