Dosimetric analysis of intensity-modulated radiation therapy and volumetric-modulated arc therapy in comparison with conventional box technique in the treatment of carcinoma cervix: An impact of prosthetic implant

被引:1
|
作者
Bhushan, Manindra [1 ,2 ]
Tripathi, Deepak [2 ]
Yadav, Girigesh [1 ]
Kumar, Lalit [1 ,3 ]
Chowdhary, Rahul Lal [1 ]
Pahuja, Anjali K. [1 ]
Suhail, Mahamood [1 ]
Mitra, Swarupa [1 ]
Gairola, Munish [1 ]
机构
[1] Rajiv Gandhi Canc Inst & Res Ctr, Div Med Phys, Dept Radiat Oncol, New Delhi, India
[2] Amity Univ, Amity Sch Appl Sci, Dept Phys, Noida, Uttar Pradesh, India
[3] Dr APJ Abdul Kalam Tech Univ, Dept Appl Sci & Human, Lucknow, Uttar Pradesh, India
关键词
High-density implant; intensity-modulated radiation therapy; prosthesis; radiotherapy; volumetric-modulated arc therapy; METALLIC HIP PROSTHESES; PHOTON-BEAM ENERGY; PROSTATE-CANCER; PLAN QUALITY; RADIOTHERAPY; IRRADIATION; RAPIDARC; NUMBER; TISSUE; IMRT;
D O I
10.4103/jcrt.JCRT_835_20
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The number of patients for carcinoma cervix with implanted hip prostheses has been increasing worldwide during the past several decades. Technological advancements are useful for delivering higher doses, i.e., dose escalation to the target, but the presence of high-density implanted hip prosthesis creates challenges for the planner. Materials and Methods: A population of 25 patients was selected for the study. Plans were generated using the MONACO treatment planning system keeping the isocenter same. The parameters evaluated for planning target volume (PTV) were D-98%, D-50%, D-2%, D-max, D-mean, V-107%, and V-110%. Similarly, the parameters D-max, D-mean, and D-2cc were evaluated for the delineated critical organs. Average monitor units (TMUmean) were also assessed. Results: D-98% of PTV was 44.51 (standard deviation [SD]: 0.13) Gy, 44.41 (SD: 0.38) Gy, 44.58 (SD: 0.14) Gy, 44.08 (SD: 0.41) Gy and 44.46 (SD: 0.32) Gy for 4F, intensity-modulated radiation therapy (IMRT), IMRT_WP, volumetric-modulated arc therapy (VMAT), and VMAT_WP techniques, respectively, where WP stands for "without prosthesis". Volume of bowel receiving 45 Gy was 86.82 (SD: 66.38) cm(3), 6.97 (SD: 5.77) cm(3), 14.11 (SD: 14.29) cm(3), 13.31 (SD: 6.57) cm(3), and 10.31 (SD: 10.94) cm(3) for 4F, IMRT, IMRT_WP, VMAT and VMAT_WP techniques, respectively. Conclusion: VMAT has an edge over other techniques in terms of target coverage and sparing of critical organs in the presence of metallic prosthesis. Information about the geometry and density of prosthesis will be beneficial for treatment planning.
引用
收藏
页码:1504 / 1512
页数:9
相关论文
共 50 条
  • [11] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Vieillot, Sabine
    Azria, David
    Lemanski, Claire
    Moscardo, Carmen Llacer
    Gourgou, Sophie
    Dubois, Jean-Bernard
    Ailleres, Norbert
    Fenoglietto, Pascal
    RADIATION ONCOLOGY, 2010, 5
  • [12] Dosimetric Comparison of Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy in Craniospinal Radiotherapy of Childhood
    Ozer, Elif Eda
    Coban, Yasin
    Cifter, Fulya
    Karacam, Songul
    Uzel, Omer
    Turkan, Tahir Sedat
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 96 - 103
  • [13] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Sabine Vieillot
    David Azria
    Claire Lemanski
    Carmen Llacer Moscardo
    Sophie Gourgou
    Jean-Bernard Dubois
    Norbert Aillères
    Pascal Fenoglietto
    Radiation Oncology, 5
  • [14] Comparison of dosimetric benefits in nasopharyngeal carcinoma patients among intensity-modulated radiotherapy, volumetric-modulated arc therapy and tomotherapy
    Xiong, W.
    Guoqiang, X.
    Wang, Q.
    Xu, T.
    Cao, R.
    Zhu, L.
    ANNALS OF ONCOLOGY, 2021, 32 : S793 - S793
  • [15] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [16] Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels
    Onal, Cem
    ArsIan, Gungor
    Dolek, Yemliha
    Efe, Esma
    Medical Dosimetry, 2016, 41 (04) : 310 - 314
  • [17] Validation of Delivery Consistency for Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy Plans
    Woon, Wui Ann
    Ravindran, Paul B.
    Ekayanake, Piyasiri
    Lim, Yivonne Yih Fang
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 119 - 128
  • [18] Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer
    Barsky, Andrew R.
    George, Jerry
    Wroe, Andrew J.
    Mittauer, Kathryn E.
    Kaiser, Adeel
    Herrera, Roberto
    Yu, Jen
    Gutierrez, Alonso N.
    Alvarez, Diane
    McCulloch, James
    Kasper, Michael E.
    Mehta, Minesh P.
    Chuong, Michael D.
    MEDICAL DOSIMETRY, 2024, 49 (02) : 121 - 126
  • [19] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [20] Dosimetric Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Tadiotherapy of Cervical Carcinoma
    Liu, T.
    Zhang, G.
    Tao, C.
    Sun, T.
    Lin, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 375 - 375