Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer

被引:0
|
作者
Barsky, Andrew R. [1 ,4 ]
George, Jerry [2 ]
Wroe, Andrew J. [3 ]
Mittauer, Kathryn E. [3 ]
Kaiser, Adeel [3 ]
Herrera, Roberto [3 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Alvarez, Diane [3 ]
McCulloch, James [3 ]
Kasper, Michael E. [1 ]
Mehta, Minesh P. [3 ]
Chuong, Michael D. [3 ]
机构
[1] Baptist Hlth South Florida, Lynn Canc Inst, Dept Radiat Oncol, Boca Raton, FL 33486 USA
[2] Orlando Hlth Canc Inst, Dept Radiat Oncol, Orlando, FL 32806 USA
[3] Miami Canc Inst, Dept Radiat Oncol, Miami, FL 33176 USA
[4] Lynn Canc Inst, Dept Radiat Oncol, 701 NW 13th St, Boca Raton, FL 33486 USA
关键词
Esophageal Cancer; MR-guided radiation Therapy; Radiation oncology; Proton therapy; Dosimetry; RADIOTHERAPY; TRIAL;
D O I
10.1016/j.meddos.2023.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Advances in radiotherapy (RT) technologies permit significant decreases in the dose delivered to organs at risk (OARs) for patients with esophageal cancer (EC). Novel RT modalities such as proton beam therapy (PBT) and magnetic resonance-guided radiotherapy (MRgRT), as well as motion management techniques including breath hold (BH) are expected to further improve the therapeutic ratio. However, to our knowledge, the dosimetric benefits of PBT vs MRgRT vs volumetric-modulated arc therapy (VMAT) have not been directly compared for EC. We performed a retrospective in silico evaluation using the images and datasets of nine distal EC patients who were treated at our institution with a 0.35-Tesla MR linac to 50.4 Gy in 28 fractions in mid-inspiration BH (BH-MRgRT). Comparison free-breathing (FB) intensitymodulated PBT (FB-IMPT) and FB-VMAT plans were retrospectively created using the same prescription dose, target volume coverage goals, and OAR constraints. A 5 mm setup margin was used for all plans. BH-IMPT and BH-VMAT plans were not evaluated as they would not reflect our institutional practice. Planners were blinded to the results of the treatment plans created using different radiation modalities. The primary objective was to compare plan quality, target volume coverage, and OAR doses. All treatment plans met pre-defined target volume coverage and OAR constraints. The median conformity and homogeneity indices between FB-IMPT, BH-MRgRT and FB-VMAT were 1.13, 1.25, and 1.43 (PITV) and 1.04, 1.15, 1.04 (HI), respectively. For FB-IMPT, BH-MRgRT and FB-VMAT the median heart dose metrics were 52.8, 79.3, 146.8 (V30Gy, cc), 35.5, 43.8, 77.5 (V40Gy, cc), 16.9, 16.9, 32.5 (V50Gy, cc) and 6.5, 14.9, 17.3 (mean, Gy), respectively. Lung dose metrics were 8.6, 7.9, 18.5 (V20Gy , %), and 4.3, 6.3, 11.2 (mean, Gy), respectively. The mean liver dose (Gy) was 6.5, 19.6, 22.2 respectively. Both FB-IMPT and BH-MRgRT achieve substantial reductions in heart, lung, and liver dose compared to FB-VMAT. We plan to evaluate dosimetric outcomes across these RT modalities assuming consistent use of BH. (c) 2023 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [1] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [2] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [3] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [4] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [5] Dosimetric comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy in patients with cervical cancer: a meta-analysis
    Bai, Wei
    Kou, Changgui
    Yu, Weiying
    Li, Yuanyuan
    Hua, Wanqing
    Yu, Lei
    Wang, Jianfeng
    [J]. ONCOTARGETS AND THERAPY, 2018, 11 : 7179 - 7186
  • [6] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy, Eman
    Rashed, Yasser A
    AlKhaldi, Mashaal
    Day, Emma
    [J]. Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [7] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [8] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    [J]. MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [9] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [10] Dosimetric Comparison of the Newest Version Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy Plans for Angiosarcoma of the Scalp
    Mizuno, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E10 - E10