Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c

被引:0
|
作者
Khuu, HM [1 ]
Robinson, CA [1 ]
Goolsby, K [1 ]
Hardy, RW [1 ]
Konrad, RJ [1 ]
机构
[1] Univ Alabama Birmingham, Dept Pathol, Div Lab Med, Birmingham, AL 35233 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction.-Measurement of hemoglobin A(1c) (HbA(1c)) is used as an objective measure of long-term blood glucose control in diabetic patients. Recent improvements in automation combined with new recommendations for precision and accuracy have caused us to reevaluate our methods for measuring HbA(1c). Objective,We evaluated a newly automated high-performance liquid chromatography (HPLC) instrument for measurement of HbA(1c) (Tosoh A(1c) 2.2 Plus Glycohemoglobin Analyzer, Tosoh Medics, Foster City, Calif) and compared the results obtained by HPLC to those obtained with an immunoassay (Hitachi 911, Boehringer Mannheim Corporation, Indianapolis, Ind). Results.-The Tosoh analyzer was found to be linear in a range of 5.3% to 17% and had a throughput of 20 samples per hour. HbA(1c) results for 102 patient samples by the 2 techniques showed good correlation, with a slope of 0.87 and an intercept at 1.27% +/- 0.15%. Both the total and within-run coefficients of variation were consistently lower for the HPLC method compared with the immunoassay method. The HPLC method produces a chromatogram that shows the different hemoglobin fractions, allowing identification of abnormal hemoglobin variants. in heterozygous individuals, HbA(1c) measurements are made with no interference from the hemoglobin variant. In the case of homozygous or doubly heterozygous hemoglobin variants, the Tosoh HPLC identifies the hemoglobin variants as such and correctly does not report a HbA(1c) value in the presence of a markedly decreased amount of hemoglobin A. Conclusions.-The Tosoh HPLC provides adequate throughput and improved precision, and the method is traceable to the Diabetes Control and Complications Trial.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [21] Standardization of method for determining glycosylated hemoglobin (Hb A1c) by cation exchange high performance liquid chromatography
    Antunes, Marina Venzon
    Wagner, Sandrine Comparsi
    Camargo, Joiza Lins
    Linden, Rafael
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 45 (04) : 651 - 657
  • [22] Analytical Performance Evaluation of Newly Developed Glycated Reagents for Hemoglobin A1c Assay
    Tian, Ke
    Yan, Nan
    Wang, Hongying
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (03): : 535 - 540
  • [23] Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies
    Chandrashekar, Vani
    SCIENTIFICA, 2016, 2016
  • [24] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MEAKIN, G
    ALLINGTON, R
    AMERICAN LABORATORY, 1980, 12 (08) : 65 - &
  • [25] Multicenter evaluation of hemoglobin A1c assay on capillary electrophoresis
    Marinova, Mariela
    Altinier, Sara
    Caldini, Anna
    Passerini, Gabriella
    Pizzagalli, Giorgio
    Brogi, Marco
    Zaninotto, Martina
    Ceriotti, Ferruccio
    Plebani, Mario
    CLINICA CHIMICA ACTA, 2013, 424 : 207 - 211
  • [26] RAPID MEASUREMENT OF SERUM CORTISOL BY FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NOZAKI, O
    OHATA, T
    OHBA, Y
    MORIYAMA, H
    KATO, Y
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1217 - 1217
  • [27] Performance of Hemoglobin A1c Assay Methods: Good Enough?
    Little, Randie R.
    CLINICAL CHEMISTRY, 2014, 60 (08) : 1031 - 1033
  • [28] High-Performance Liquid Chromatography for Screening of Abnormal Hemoglobins in Blood Donors Allows the Identification of Diabetic Individuals through the Detection of A1C Hemoglobin
    Pereira, R. A.
    Polite, M. B.
    Cabral, S. P.
    Farinha, M. T.
    Lira, S. C.
    Mota, M. A.
    Levi, J.
    Kutner, J. M.
    TRANSFUSION, 2013, 53 : 99A - 99A
  • [29] Inaccuracy of high-performance liquid chromatography estimation of haemoglobin F in the presence of increased haemoglobin A1c
    Grey, V.
    Wilkinson, M.
    Phelan, L.
    Hughes, C.
    Bain, B. J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 (01) : 42 - 44
  • [30] A CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR HEMOGLOBIN-A1C AND HEMOGLOBIN SCREENING
    OU, CN
    CARMONA, P
    CLINICAL CHEMISTRY, 1985, 31 (06) : 945 - 945