Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c

被引:0
|
作者
Khuu, HM [1 ]
Robinson, CA [1 ]
Goolsby, K [1 ]
Hardy, RW [1 ]
Konrad, RJ [1 ]
机构
[1] Univ Alabama Birmingham, Dept Pathol, Div Lab Med, Birmingham, AL 35233 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction.-Measurement of hemoglobin A(1c) (HbA(1c)) is used as an objective measure of long-term blood glucose control in diabetic patients. Recent improvements in automation combined with new recommendations for precision and accuracy have caused us to reevaluate our methods for measuring HbA(1c). Objective,We evaluated a newly automated high-performance liquid chromatography (HPLC) instrument for measurement of HbA(1c) (Tosoh A(1c) 2.2 Plus Glycohemoglobin Analyzer, Tosoh Medics, Foster City, Calif) and compared the results obtained by HPLC to those obtained with an immunoassay (Hitachi 911, Boehringer Mannheim Corporation, Indianapolis, Ind). Results.-The Tosoh analyzer was found to be linear in a range of 5.3% to 17% and had a throughput of 20 samples per hour. HbA(1c) results for 102 patient samples by the 2 techniques showed good correlation, with a slope of 0.87 and an intercept at 1.27% +/- 0.15%. Both the total and within-run coefficients of variation were consistently lower for the HPLC method compared with the immunoassay method. The HPLC method produces a chromatogram that shows the different hemoglobin fractions, allowing identification of abnormal hemoglobin variants. in heterozygous individuals, HbA(1c) measurements are made with no interference from the hemoglobin variant. In the case of homozygous or doubly heterozygous hemoglobin variants, the Tosoh HPLC identifies the hemoglobin variants as such and correctly does not report a HbA(1c) value in the presence of a markedly decreased amount of hemoglobin A. Conclusions.-The Tosoh HPLC provides adequate throughput and improved precision, and the method is traceable to the Diabetes Control and Complications Trial.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [31] SEPARATION OF GLYCATED HEMOGLOBIN-A1C BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A NONPOROUS EXCHANGER
    NAKATANI, S
    KITAMURA, T
    YAMASAKI, Y
    KATO, Y
    CHROMATOGRAPHIA, 1991, 31 (9-10) : 505 - 506
  • [32] FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE ANALYSIS OF FREE CATECHOLAMINES IN URINE
    SAID, R
    ROBINET, D
    BARBIER, C
    SARTRE, J
    HUGUET, C
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01): : 11 - 18
  • [33] Performance evaluation of three automated high performance liquid chromatography HBA1C analysers
    Lim, M. H.
    Koh, B. M. Q.
    Yeo, C. P.
    CLINICA CHIMICA ACTA, 2022, 530 : S293 - S293
  • [34] Evaluation of D10® hemoglobin testing system for hemoglobin A1C assay
    Marzullo, C.
    Minery, M.
    ANNALES DE BIOLOGIE CLINIQUE, 2008, 66 (01) : 95 - 99
  • [35] Evaluation of Three Turbidimetric Assays for Automated Determination of Hemoglobin A1c
    Barrot, Amandine
    Dupuy, Anne Marie
    Badiou, Stephanie
    Bargnoux, Anne Sophie
    Cristol, Jean Paul
    CLINICAL LABORATORY, 2012, 58 (11-12) : 1171 - 1177
  • [36] Performance of the BM/Hitachi 912 hemoglobin A1c assay.
    Altaffer, MB
    Velazquez, FR
    Thomson, J
    Ng, KM
    CLINICAL CHEMISTRY, 1997, 43 : 224 - 224
  • [37] Evaluation of the Tosoh 2.2 plus hemoglobin A1c assay.
    Yeo, KT
    Linscott, J
    Fitzmaurice, T
    CLINICAL CHEMISTRY, 1998, 44 : A30 - A30
  • [38] Automated method development in high-performance liquid chromatography
    Snyder, LR
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A: FUNDAMENTALS, 1996, 270 : 151 - 175
  • [39] Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype: a case report
    Sadriani, Nadia
    Marpaung, Ferdy Royland
    BIOCHEMIA MEDICA, 2023, 33 (03)
  • [40] Assay of amikacin in the skin by high-performance liquid chromatography
    Nicoli, S
    Santi, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 994 - 997