Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c

被引:0
|
作者
Khuu, HM [1 ]
Robinson, CA [1 ]
Goolsby, K [1 ]
Hardy, RW [1 ]
Konrad, RJ [1 ]
机构
[1] Univ Alabama Birmingham, Dept Pathol, Div Lab Med, Birmingham, AL 35233 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction.-Measurement of hemoglobin A(1c) (HbA(1c)) is used as an objective measure of long-term blood glucose control in diabetic patients. Recent improvements in automation combined with new recommendations for precision and accuracy have caused us to reevaluate our methods for measuring HbA(1c). Objective,We evaluated a newly automated high-performance liquid chromatography (HPLC) instrument for measurement of HbA(1c) (Tosoh A(1c) 2.2 Plus Glycohemoglobin Analyzer, Tosoh Medics, Foster City, Calif) and compared the results obtained by HPLC to those obtained with an immunoassay (Hitachi 911, Boehringer Mannheim Corporation, Indianapolis, Ind). Results.-The Tosoh analyzer was found to be linear in a range of 5.3% to 17% and had a throughput of 20 samples per hour. HbA(1c) results for 102 patient samples by the 2 techniques showed good correlation, with a slope of 0.87 and an intercept at 1.27% +/- 0.15%. Both the total and within-run coefficients of variation were consistently lower for the HPLC method compared with the immunoassay method. The HPLC method produces a chromatogram that shows the different hemoglobin fractions, allowing identification of abnormal hemoglobin variants. in heterozygous individuals, HbA(1c) measurements are made with no interference from the hemoglobin variant. In the case of homozygous or doubly heterozygous hemoglobin variants, the Tosoh HPLC identifies the hemoglobin variants as such and correctly does not report a HbA(1c) value in the presence of a markedly decreased amount of hemoglobin A. Conclusions.-The Tosoh HPLC provides adequate throughput and improved precision, and the method is traceable to the Diabetes Control and Complications Trial.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [41] AUTOMATED OPTIMIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BERRIDGE, JC
    ANALYTICA CHIMICA ACTA, 1986, 191 : 243 - 259
  • [42] ASSAY OF GALACTOSYLTRANSFERASE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HYMES, AJ
    MULLINAX, F
    ANALYTICAL BIOCHEMISTRY, 1984, 139 (01) : 68 - 72
  • [43] ASSAY OF ASPARTYLGLYCOSYLAMINASE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KAARTINEN, V
    MONONEN, I
    ANALYTICAL BIOCHEMISTRY, 1990, 190 (01) : 98 - 101
  • [44] A pitfall in hemoglobin A1c measurement with high performance liquid chromatography method in the diagnosis of onset of fulminant type 1 diabetes mellitus
    Oe, Yasuharu
    Anno, Takatoshi
    Katsuhara, Yukari
    Sugahara, Ryo
    Kobayashi, Miki
    Yakusue, Mieko
    Tamura, Masayo
    Kimura, Yukiko
    Kawasaki, Fumiko
    Kaku, Kohei
    Kaneto, Hideaki
    Kitanaka, Akira
    JOURNAL OF DIABETES INVESTIGATION, 2022, 13 (11) : 1943 - 1944
  • [45] Degradation analysis of human hemoglobin by high-performance liquid chromatography
    Row, KH
    Lee, SK
    Polyakova, Y
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2004, 10 (03) : 478 - 483
  • [46] DETERMINATION OF CARBAMYLATED HEMOGLOBIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KWAN, JTC
    CARR, EC
    BENDING, MR
    BARRON, JL
    CLINICAL CHEMISTRY, 1990, 36 (04) : 607 - 610
  • [47] DEVELOPMENT OF AN ASSAY FOR HISTAMINE USING AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    JENSEN, TB
    MARLEY, PD
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 670 (02): : 199 - 207
  • [48] EVALUATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR ROUTINE ESTIMATION OF HEMOGLOBIN-A(2) AND HEMOGLOBIN-F
    TAN, GB
    AW, TC
    DUNSTAN, RA
    LEE, SH
    JOURNAL OF CLINICAL PATHOLOGY, 1993, 46 (09) : 852 - 856
  • [49] Performance Evaluation of the Bio-Rad D-100 System for Hemoglobin A1c Assay
    Jeong, Tae-Dong
    Park, Sholhui
    Hong, Ki-Sook
    CLINICAL LABORATORY, 2017, 63 (11-12) : 1923 - 1928
  • [50] CONTINUOUS BODY-FLUID MONITORING FOR ZOMEPIRAC BY FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MULLER, H
    ZULLIGER, HW
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1985, 35 (01): : 152 - 154