Multicenter evaluation of hemoglobin A1c assay on capillary electrophoresis

被引:25
|
作者
Marinova, Mariela [1 ]
Altinier, Sara [1 ]
Caldini, Anna [2 ]
Passerini, Gabriella [3 ]
Pizzagalli, Giorgio [3 ]
Brogi, Marco [2 ]
Zaninotto, Martina [1 ]
Ceriotti, Ferruccio [3 ]
Plebani, Mario [1 ]
机构
[1] Univ Hosp Padova, Dept Lab Med, I-35128 Padua, Italy
[2] Careggi Univ Hosp, Gen Lab, Lab Diagnost Dept, I-50134 Florence, Italy
[3] Osped San Raffaele, Ist Sci, Diagnost & Ric San Raffaele, I-20123 Milan, Italy
关键词
Capillary electrophoresis; Diabetes; HPLC; HbA(1c); BIOLOGICAL VARIATION; HBA(1C); GLUCOSE; GOALS; A1C;
D O I
10.1016/j.cca.2013.06.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hemoglobin A(1c) (HbA(1c)) measurement is currently used for the routine monitoring of long-term glycemic status, thus playing a fundamental role in the management of this disease. Since this marker has recently been recommended as an additional tool for diagnosing diabetes, it's of the utmost importance to ensure that the precision and accuracy of HbA(1c) methods are satisfactory. Methods: We assessed the analytical performances of the Capillarys 2 Flex Piercing (R) analyzer and compared the results obtained with those from two other widely used HPLC instruments. Furthermore, we evaluated the convenience and ergonomics of the system in authentic routine work conditions in three centers. Results: Within-laboratory (n = 40) and between-laboratory (n = 120) imprecision CV% using four blood samples with different concentrations of HbA(1c) were <3.4% and <3.1% using IFCC units and <2.1% and <2.0% using NGSP units, respectively. The obtained trueness (<3 mmol/mol, <0.3%) was highly satisfactory, nor was HbA(1c) measurement compromised by the presence of the commonly present hemoglobinopathies. The comparison made with established methods revealed excellent agreement (r > 0.985). Conclusions: The evaluated method is precise, accurate and robust, with a high throughput. It also allows the identification of the most frequent Hb variants and therefore may be a valid alternative to other methods currently proposed for routine use in clinical laboratories. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 50 条
  • [1] Evaluation of an Enzymatic Hemoglobin A1C Assay
    Majeed, Numan
    Kanani, Fatima
    Zubairi, Adnan Mustafa
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2024, 30 (02): : 184 - 190
  • [2] Evaluation of an immunoturbidimetric assay for hemoglobin A1c
    Akan, P
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 187 - 193
  • [3] Analysis of glycated hemoglobin A1c by capillary electrophoresis and capillary isoelectric focusing
    Koval, Dusan
    Kasicka, Vaclav
    Cottet, Herve
    ANALYTICAL BIOCHEMISTRY, 2011, 413 (01) : 8 - 15
  • [4] A NOVEL MEANS OF IDENTIFYING HEMOGLOBIN TACOMA UTILIZING CAPILLARY ELECTROPHORESIS WITH HEMOGLOBIN A1C SOFTWARE PLATFORM
    Sandercock, Nicholas
    Merkeley, Hayley
    Halchuk, Linda
    Braga, Manoela
    Verhovsek, Madeleine
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 126 - 126
  • [5] Consolidation and evaluation of hemoglobin A1C, hemoglobin electrophoresis and serum protein electrophoresis on the Sebia Capillarys 2 platform
    Thomas, Dylan
    Mione, Anthony M.
    Schrader, Jeff
    Kim, Sarah
    Keillor, Aimee
    Prelich, Halina
    Grzelak, Ela
    Pasic, Maria
    CLINICAL BIOCHEMISTRY, 2015, 48 (15) : 1015 - 1015
  • [6] Evaluation of D10® hemoglobin testing system for hemoglobin A1C assay
    Marzullo, C.
    Minery, M.
    ANNALES DE BIOLOGIE CLINIQUE, 2008, 66 (01) : 95 - 99
  • [7] Evaluation of the Tosoh 2.2 plus hemoglobin A1c assay.
    Yeo, KT
    Linscott, J
    Fitzmaurice, T
    CLINICAL CHEMISTRY, 1998, 44 : A30 - A30
  • [8] Prevalence of Rare Hemoglobin Variants Identified During Measurements of Hb A1c by Capillary Electrophoresis
    Strickland, Sydney W.
    Campbell, Sean T.
    Little, Randie R.
    Bruns, David E.
    Bazydlo, Lindsay A. L.
    CLINICAL CHEMISTRY, 2017, 63 (12) : 1901 - 1902
  • [9] Hb A1c Determination by Capillary Electrophoresis is an Efficient Method for Detecting -Thalassemias and Hemoglobin Variants
    Orts, Juan A.
    Zuniga, Angel
    Bello, Yanis
    Fabregat, Aleix B.
    Vicente, Ana I.
    HEMOGLOBIN, 2016, 40 (05) : 335 - 340
  • [10] Hemoglobin Camperdown [β104Arg→Ser] Detection During Hemoglobin A1c Measurement via Capillary Electrophoresis
    Brunel, Valery
    Caneiro, Patrick
    Lahary, Agnes
    Hue, Guy
    Thuillez, Christian
    ANNALS OF LABORATORY MEDICINE, 2016, 36 (04) : 375 - 376