Anterior chamber depth measurement before and after photorefractive keratectomy - Comparison between IOL master and Orbscan II

被引:24
|
作者
Rosa, N [1 ]
Lanza, M [1 ]
Capasso, L [1 ]
Lucci, M [1 ]
Polito, B [1 ]
Romano, A [1 ]
机构
[1] Univ Naples 2, Dept Ophthalmol, I-80100 Naples, Italy
关键词
D O I
10.1016/j.ophtha.2006.02.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure the anterior chamber depth (ACD) with 2 different devices before and after photorefractive keratectomy (PRK). Design: Noncomparative case series. Participants: One hundred forty-three eyes of 143 patients who had undergone PRK with refractive errors ranging from -13.13 diopters (D) to +7 D (mean, -3.67 +/- 3.58) were analyzed. Methods: The ACD values preoperatively and at 1, 3, and 6 months postoperatively were measured with the Orbscan II and IOL Master. The results were analyzed using the Pearson correlation. Main Outcome Measure: Anterior chamber depth. Results: The instruments showed good agreement between the measurements before and after surgery. A significant decrease between the preoperative and 1-month postoperative measurements was found in the ACD measured from the epithelium with Orbscan II (P < 0.01) and IOL Master (P < 0.01). A nonsignificant decrease with both IOL Master (P > 0.01) and Orbscan II (P > 0.01) was found between 3 and 6 months after surgery. The ACD measured from the endothelium using the Orbscan II showed a significant difference only between the 3- and 6-month follow-up data (P < 0.01). Conclusions: The 2 devices showed good agreement, and the changes detected postoperatively seem to be related not only to corneal thinning but also to anterior segment remodeling.
引用
收藏
页码:962 / 969
页数:8
相关论文
共 50 条
  • [21] Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth
    Haya Matuoq Al Farhan
    BMC Ophthalmology, 14
  • [22] A compative study: Orbscan II vs. ultrasound biomicroscopy as a method to assess the anterior chamber depth
    Perez, B
    Orlich, C
    Reyes, DS
    Velasco, CF
    Ozorno, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U9 - U9
  • [23] ULTRASOUND BASED MEASUREMENT OF INDIVIDUAL VARIATIONS IN ANTERIOR-CHAMBER DEPTH FOR IOL CALCULATION PURPOSES
    WOODS, S
    COLEMAN, DJ
    ALLEMANN, N
    SILVERMAN, R
    VINARSKY, E
    REINSTEIN, DZ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 885 - 885
  • [24] Comparison of anterior chamber depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and emmetropic eyes
    Utine, Canan Asli
    Altin, Feyza
    Cakir, Hanefi
    Perente, Irfan
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 386 - 391
  • [25] Comparison of optical low coherence reflectometry and ultrasound pachymetry in the measurement of central corneal thickness before and after photorefractive keratectomy
    Spadea, Leopoldo
    Giammaria, Daniele
    Di Genova, Lucia
    Fiasca, Arianna
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (07) : 661 - 666
  • [26] Endothelial cell loss after phacoemulsification according to different anterior chamber depths measured by IOL master
    Hwang, H.
    Lyu, B.
    Yim, H.
    Lee, N.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [27] MEASUREMENT OF INTRAOCULAR DISTANCES BY ULTRASOUND AND COMPARISON BETWEEN OPTICAL AND ULTRASONIC DETERMINATIONS OF DEPTH OF ANTERIOR CHAMBER
    JANSSON, F
    ACTA OPHTHALMOLOGICA, 1963, 41 (01): : 25 - &
  • [28] Comparison of the IOL Master and Pentacam in the measurement of anterior segment parameters in patients with high myopia and cataracts
    Li, L.
    Li, Y. J.
    Liu, M.
    Yu, F. L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (07):
  • [29] Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes
    Kriechbaum, K
    Findl, O
    Kiss, B
    Sacu, S
    Petternel, V
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 89 - 94
  • [30] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347