Anterior chamber depth measurement before and after photorefractive keratectomy - Comparison between IOL master and Orbscan II

被引:24
|
作者
Rosa, N [1 ]
Lanza, M [1 ]
Capasso, L [1 ]
Lucci, M [1 ]
Polito, B [1 ]
Romano, A [1 ]
机构
[1] Univ Naples 2, Dept Ophthalmol, I-80100 Naples, Italy
关键词
D O I
10.1016/j.ophtha.2006.02.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure the anterior chamber depth (ACD) with 2 different devices before and after photorefractive keratectomy (PRK). Design: Noncomparative case series. Participants: One hundred forty-three eyes of 143 patients who had undergone PRK with refractive errors ranging from -13.13 diopters (D) to +7 D (mean, -3.67 +/- 3.58) were analyzed. Methods: The ACD values preoperatively and at 1, 3, and 6 months postoperatively were measured with the Orbscan II and IOL Master. The results were analyzed using the Pearson correlation. Main Outcome Measure: Anterior chamber depth. Results: The instruments showed good agreement between the measurements before and after surgery. A significant decrease between the preoperative and 1-month postoperative measurements was found in the ACD measured from the epithelium with Orbscan II (P < 0.01) and IOL Master (P < 0.01). A nonsignificant decrease with both IOL Master (P > 0.01) and Orbscan II (P > 0.01) was found between 3 and 6 months after surgery. The ACD measured from the endothelium using the Orbscan II showed a significant difference only between the 3- and 6-month follow-up data (P < 0.01). Conclusions: The 2 devices showed good agreement, and the changes detected postoperatively seem to be related not only to corneal thinning but also to anterior segment remodeling.
引用
收藏
页码:962 / 969
页数:8
相关论文
共 50 条
  • [31] Ultrasound biomicroscopic measurement of anterior chamber biometry between before and after pupil dilation in children
    Tsuchiya, A. K.
    Tanaka, K.
    Sakurada, I.
    Oba, S.
    Mizuki, N.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (04) : 532 - 539
  • [32] Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith’s technique, and van Herick’s method
    Frank Eperjesi
    Claire Holden
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 449 - 454
  • [33] Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith's technique, and van Herick's method
    Eperjesi, Frank
    Holden, Claire
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) : 449 - 454
  • [35] A comparison between Goldmann applanation tonometry and dynamic contour tonometry after photorefractive keratectomy
    Sadigh, Afshin Lotfi
    Fouladi, Rohollah F.
    Hashemi, Hassan
    Beheshtnejad, Amir Houshang
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (02) : 603 - 608
  • [36] A comparison between Goldmann applanation tonometry and dynamic contour tonometry after photorefractive keratectomy
    Afshin Lotfi Sadigh
    Rohollah F. Fouladi
    Hassan Hashemi
    Amir Houshang Beheshtnejad
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 603 - 608
  • [37] Comparison of Corneal and Anterior Chamber Parameters following Myopic Laser in Situ Keratomileusis and Photorefractive Keratectomy by Pentacam as A New Imaging Technique
    Zare, Mohammad Ali
    Hashemi, Hassan
    Jamali, Mahtab
    Tafti, Mohammadreza Fallah
    Hashemian, Mohammad Naser
    Kheirkhah, Ahmad
    Z-Mehrjardi, Hadi
    Mohammadpour, Mehrdad
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2011, 23 (01): : 27 - 32
  • [38] Agreement on Anterior Chamber Depth Measurement between Three Commercially Available Devices
    Noya-Padin, Veronica
    Pena-Verdeal, Hugo
    Garcia-Queiruga, Jacobo
    Sampedro-Marino, Irene
    Giraldez, Maria Jesus
    Yebra-Pimentel, Eva
    PHOTONICS, 2024, 11 (04)
  • [39] Measurement of the anterior chamber depth and ocular axial length: transpalpebral B-mode ultrasound using an 18-MHz linear probe compared with the IOL Master 500
    Gutierrez-Vazquez, Julia
    Ismael Perez-Sanchez, Lorenzo
    Satrustegui-Lapetra, Maria
    Jose Arevalo-Manso, Juan
    Jesus Gomez-Herrera, Juan
    Jose Criado-Alvarez, Juan
    MEDICAL ULTRASONOGRAPHY, 2021, 23 (01) : 48 - 54
  • [40] Comparison between IOL MASTER 500 and MYAH with vector analysis in low and mild anterior corneal astigmatism
    Camellin, Umberto
    Franchina, Francesco
    Latino, Gianluigi
    Ninotta, Ivan
    Palino, Paola
    Meduri, Alessandro
    Aragona, Pasquale
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (04) : 1046 - 1052