Comparison of optical low coherence reflectometry and ultrasound pachymetry in the measurement of central corneal thickness before and after photorefractive keratectomy

被引:17
|
作者
Spadea, Leopoldo [1 ]
Giammaria, Daniele [1 ]
Di Genova, Lucia [1 ]
Fiasca, Arianna [1 ]
机构
[1] Univ Aquila, I-67100 Laquila, Italy
关键词
D O I
10.3928/1081-597X-20070901-04
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare an ultrasound pachymeter with an optical low coherence reflectometry (OLCR) pachymeter for measuring pre- and postoperative central corneal thickness of patients undergoing photorefractive keratectomy (PRK). METHODS: In a prospective, noncomparative, interventional study, 48 myopic eyes (mean manifest refractive spherical equivalent: -4.93 +/- 2.93 diopters [D]) of 30 healthy patients underwent PRK Pre- and postoperative central corneal thickness was measured by two examiners (El, E2) with an ultrasound pachymeter and an OLCR pachymeter. Agreement and inter-rater repeatability were determined using the comparison method described by Bland and Altman. RESULTS: The limits of agreement between the two devices ranged from 17.8 mu m (E1) to 20.5 mu m (E2) preoperatively and from 22.4 mu m (E1) to 16.9 mu m (E2) postoperatively. The coefficient of inter-rater repeatability ranged from 9.1 mu m (ultrasound pachymeter) to 5.4 mu m (OLCR pachymeter) preoperatively and from 7.1 mu m (ultrasound pachymeter) to 4.7 mu m (OLCR pachymeter) postoperatively. CONCLUSIONS: The OLCR pachymeter seems to show better pre- and postoperative repeatability compared to the ultrasound pachymeter. The agreement between the two devices should be considered acceptable for clinical practice. Photorefractive keratectomy did not affect the postoperative agreement and repeatability of the pachymeters.
引用
收藏
页码:661 / 666
页数:6
相关论文
共 50 条
  • [1] Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy
    Schneider, Miklos
    Borgulya, Gabor
    Seres, Andras
    Nagy, Zoltan Z.
    Nemeth, Janos
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (02) : 180 - 187
  • [2] Comparison of optical low-coherence reflectometry and ultrasound pachymetry in measuring corneal graft thickness
    Gaujoux, Thomas
    Borderie, Vincent M.
    Yousfi, Hakim
    Bourcier, Tristan
    Touzeau, Olivier
    Laroche, Laurent
    CORNEA, 2007, 26 (02) : 185 - 189
  • [3] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1729 - 1735
  • [4] Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both Devices
    Koktekir, Bengu E.
    Gedik, Sansal
    Bakbak, Berker
    CORNEA, 2012, 31 (11) : 1278 - 1281
  • [5] Assessment of central corneal thickness using OCT, ultrasound, optical low coherence reflectometry and Scheimpflug pachymetry
    Beutelspacher, Sven C.
    Serbecic, Nermin
    Scheuerle, Alexander F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 132 - 137
  • [6] Evaluating central corneal thickness measurements with noncontact optical low-coherence reflectometry and contact ultrasound pachymetry
    Airiani, Suzanna
    Trokel, Stephen L.
    Lee, Shing M.
    Braunstein, Richard E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (01) : 164 - 165
  • [7] Reproducibility of the measurement of central corneal thickness in healthy subjects obtained with the optical low coherence reflectometry pachymeter and comparison with the ultrasonic pachymetry
    Garza-Leon, Manuel
    Plancarte-Lozano, Eduardo
    Del Valle-Penella, Agustin
    de Lourdes Guzman-Martinez, Maria
    Villarreal-Gonzalez, Andres
    CIRUGIA Y CIRUJANOS, 2018, 86 (01): : 44 - 49
  • [8] Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness
    Rainer, G
    Petternel, V
    Findl, O
    Schmetterer, L
    Skorpik, C
    Luksch, A
    Drexler, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2142 - 2145
  • [9] Central Corneal Thickness Measurement with Online Optical Coherence Pachymetry and Ultrasound Pachymetry in 513 Consecutive Eyes
    von Jagow, B.
    Kuehne, C.
    Kohnen, T.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (08) : 645 - 648
  • [10] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754