Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments

被引:33
|
作者
Mancuso, Gordon M. [2 ,3 ]
Fontenot, Jonas D. [1 ,2 ,3 ]
Gibbons, John P. [1 ,2 ,3 ]
Parker, Brent C. [4 ]
机构
[1] Mary Bird Perkins Canc Ctr, Dept Phys, Baton Rouge, LA 70809 USA
[2] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[3] Agr & Mech Coll, Baton Rouge, LA 70803 USA
[4] Univ Texas Med Branch, Dept Radiat Oncol, Galveston, TX 77555 USA
关键词
volumetric modulated arc therapy; intensity modulated radiation therapy; quality assurance; action levels; PASSING RATES; IMRT; VMAT; DOSIMETRY; DELIVERY; QA; VERIFICATION; TOMOTHERAPY; PHANTOM;
D O I
10.1118/1.4729738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. Methods: Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by AAPM Task Group 119. The plans were repeatedly delivered across multiple measurement sessions, and the resulting dose distributions were measured with (1) radiochromic film and ionization chamber and (2) a commercial two-dimensional diode array. The resulting QA measurements from each delivery technique were then analyzed, compared, and tested for statistically significant differences. Results: Although differences were noted between QA results for some plans, neither modality showed consistently better agreement of measured and planned doses: of the 22 comparisons, IMRT showed better QA results in 11 cases, and VMAT showed better QA results in 11 cases. No statistically significant differences (p < 0.05) between IMRT and VMAT QA results were found for point doses measured with an ionization chamber, planar doses measured with radiochromic film, or planar doses measured with a two-dimensional diode array. Conclusions: These results suggest that it is appropriate to apply patient-specific QA action levels derived from fixed-beam IMRT to VMAT. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729738]
引用
收藏
页码:4378 / 4385
页数:8
相关论文
共 50 条
  • [31] Comparison of Dosimetric Analysis of Volumetric Modulated Arc Therapy Vs Intensity Modulated Radiation Therapy for Anal Cancer
    Chiang, B.
    Hibbitts, K.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E305 - E305
  • [32] Dosimetric Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Soft Tissue Sarcoma of the Extremities
    Lawless, Anna K.
    Fangupo, Nonga
    Estoesta, Reuben Patrick
    Perez, Gino
    Alzaidi, Samara
    Heller, Gillian
    Hill, Robin
    Hong, Angela M.
    PRACTICAL RADIATION ONCOLOGY, 2022, 12 (04) : E306 - E311
  • [33] Dosimetric Comparison of Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy in Craniospinal Radiotherapy of Childhood
    Ozer, Elif Eda
    Coban, Yasin
    Cifter, Fulya
    Karacam, Songul
    Uzel, Omer
    Turkan, Tahir Sedat
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 96 - 103
  • [34] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [35] The role of volumetric modulated arc therapy (VMAT) in gynaecological radiation therapy: A dosimetric comparison of intensity modulated radiation therapy versus VMAT
    Knapp, Penelope
    Eva, Belinda
    Reseigh, Gemma
    Gibbs, Adrian
    Sim, Lucy
    Daly, Tiffany
    Cox, Judith
    Bernard, Anne
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2019, 66 (01) : 44 - 53
  • [36] Multileaf Collimator Quality Assurance for Volumetric Modulated Arc Therapy
    Lin, T.
    Hossain, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3598 - U31
  • [37] Quality assurance of dynamic parameters in volumetric modulated arc therapy
    Manikandan, A.
    Sarkar, B.
    Holla, R.
    Vivek, T. R.
    Sujatha, N.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : 1002 - 1010
  • [38] Evidence based quality assurance of volumetric modulated arc therapy
    Tuemmler, H.
    Bellmann, C.
    Schilling, P.
    Schreiber, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S117 - S117
  • [39] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [40] A TPS integrated machine learning tool for predicting patient-specific quality assurance outcomes in volumetric-modulated arc therapy
    Noblet, Caroline
    Maunet, Mathis
    Duthy, Marie
    Coste, Frederic
    Moreau, Matthieu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118