Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments

被引:33
|
作者
Mancuso, Gordon M. [2 ,3 ]
Fontenot, Jonas D. [1 ,2 ,3 ]
Gibbons, John P. [1 ,2 ,3 ]
Parker, Brent C. [4 ]
机构
[1] Mary Bird Perkins Canc Ctr, Dept Phys, Baton Rouge, LA 70809 USA
[2] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[3] Agr & Mech Coll, Baton Rouge, LA 70803 USA
[4] Univ Texas Med Branch, Dept Radiat Oncol, Galveston, TX 77555 USA
关键词
volumetric modulated arc therapy; intensity modulated radiation therapy; quality assurance; action levels; PASSING RATES; IMRT; VMAT; DOSIMETRY; DELIVERY; QA; VERIFICATION; TOMOTHERAPY; PHANTOM;
D O I
10.1118/1.4729738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. Methods: Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by AAPM Task Group 119. The plans were repeatedly delivered across multiple measurement sessions, and the resulting dose distributions were measured with (1) radiochromic film and ionization chamber and (2) a commercial two-dimensional diode array. The resulting QA measurements from each delivery technique were then analyzed, compared, and tested for statistically significant differences. Results: Although differences were noted between QA results for some plans, neither modality showed consistently better agreement of measured and planned doses: of the 22 comparisons, IMRT showed better QA results in 11 cases, and VMAT showed better QA results in 11 cases. No statistically significant differences (p < 0.05) between IMRT and VMAT QA results were found for point doses measured with an ionization chamber, planar doses measured with radiochromic film, or planar doses measured with a two-dimensional diode array. Conclusions: These results suggest that it is appropriate to apply patient-specific QA action levels derived from fixed-beam IMRT to VMAT. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729738]
引用
收藏
页码:4378 / 4385
页数:8
相关论文
共 50 条
  • [41] Establishing an optimized patient-specific verification program for volumetric modulated arc therapy
    Serna, Alfredo
    Mata, Fernando
    Puchades, Vicente
    MEDICAL DOSIMETRY, 2013, 38 (03) : 274 - 279
  • [42] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Yixiao Guo
    Jinyan Hu
    Yang Li
    Juntao Ran
    Hongyi Cai
    Scientific Reports, 13
  • [43] Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT
    Sasaki, Motoharu
    Sugimoto, Wataru
    Ikushima, Hitoshi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (05) : 793 - 800
  • [44] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Guo, Yixiao
    Hu, Jinyan
    Li, Yang
    Ran, Juntao
    Cai, Hongyi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] Dosimetric Comparison of Volumetric Modulated Arc Therapy, Tomotherapy, and Intensity Modulated Radiation Therapy for Radiation Dose Escalation of Hepatic Malignancies
    Bota, K.
    Lock, M.
    Ahmad, B.
    Fisher, B.
    Yartsev, S.
    Wong, E.
    Gaede, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S381 - S382
  • [46] Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer
    Li, Zhiping
    Zeng, Jianshuang
    Wang, Zi
    Zhu, Hong
    Wei, Yuquan
    ONCOLOGY LETTERS, 2014, 8 (04) : 1427 - 1434
  • [47] An Improved Statistical Model for Gamma Index Pass Rates in Intensity Modulated Radiation Therapy Patient-Specific Quality Assurance
    Jensen, P. James
    Donahue, William
    Chen, Zhe
    MEDICAL PHYSICS, 2021, 48 (06)
  • [48] Quality assurance of intensity-modulated radiation therapy
    Palta, Jatinder R.
    Li, Chihray
    Li, Jonathan G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S108 - S112
  • [49] Dosimetric Evaluation of Noncoplanar Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery Techniques for Cervical Stereotactic Body Radiation Therapy Treatments
    Cohen, D.
    Delgado, A. Brito
    Eng, T. Y.
    Gutierrez, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E666 - E667
  • [50] Strategies for quality assurance of intensity modulated radiation therapy
    Benedek, Hunor
    Isacsson, Ulf
    Olevik-Dunder, Maria
    Westermark, Mathias
    Hallstrom, Per
    Olofsson, Jorgen
    Gustafsson, Magnus
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573