Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments

被引:33
|
作者
Mancuso, Gordon M. [2 ,3 ]
Fontenot, Jonas D. [1 ,2 ,3 ]
Gibbons, John P. [1 ,2 ,3 ]
Parker, Brent C. [4 ]
机构
[1] Mary Bird Perkins Canc Ctr, Dept Phys, Baton Rouge, LA 70809 USA
[2] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[3] Agr & Mech Coll, Baton Rouge, LA 70803 USA
[4] Univ Texas Med Branch, Dept Radiat Oncol, Galveston, TX 77555 USA
关键词
volumetric modulated arc therapy; intensity modulated radiation therapy; quality assurance; action levels; PASSING RATES; IMRT; VMAT; DOSIMETRY; DELIVERY; QA; VERIFICATION; TOMOTHERAPY; PHANTOM;
D O I
10.1118/1.4729738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. Methods: Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by AAPM Task Group 119. The plans were repeatedly delivered across multiple measurement sessions, and the resulting dose distributions were measured with (1) radiochromic film and ionization chamber and (2) a commercial two-dimensional diode array. The resulting QA measurements from each delivery technique were then analyzed, compared, and tested for statistically significant differences. Results: Although differences were noted between QA results for some plans, neither modality showed consistently better agreement of measured and planned doses: of the 22 comparisons, IMRT showed better QA results in 11 cases, and VMAT showed better QA results in 11 cases. No statistically significant differences (p < 0.05) between IMRT and VMAT QA results were found for point doses measured with an ionization chamber, planar doses measured with radiochromic film, or planar doses measured with a two-dimensional diode array. Conclusions: These results suggest that it is appropriate to apply patient-specific QA action levels derived from fixed-beam IMRT to VMAT. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729738]
引用
收藏
页码:4378 / 4385
页数:8
相关论文
共 50 条
  • [21] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [22] A management method for the statistical results of patient-specific quality assurance for intensity-modulated radiation therapy
    Nakamura, Satoshi
    Okamoto, Hiroyuki
    Wakita, Akihisa
    Umezawa, Rei
    Takahashi, Kana
    Inaba, Koji
    Murakami, Naoya
    Kato, Toru
    Igaki, Hiroshi
    Ito, Yoshinori
    Abe, Yoshihisa
    Itami, Jun
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (04) : 572 - 578
  • [23] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [24] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275
  • [25] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Han, Ce
    Zhang, Ji
    Yu, Bing
    Zheng, Haoze
    Wu, Yibo
    Lin, Zhixi
    Ning, Boda
    Yi, Jinling
    Xie, Congying
    Jin, Xiance
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [26] Dosimetric Validation for Patient-specific Quality Assurance using the Delta44 Phantom with Volumetric Modulated Arc Therapy
    Arino Gil, A.
    Calvo, O.
    Gutierrez, A.
    Papanikolau, N.
    Hdez-Armas, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S717 - S717
  • [27] Machine learning and lean six sigma for targeted patient-specific quality assurance of volumetric modulated arc therapy plans
    Lambri, Nicola
    Dei, Damiano
    Goretti, Giulia
    Crespi, Leonardo
    Brioso, Ricardo Coimbra
    Pelizzoli, Marco
    Parabicoli, Sara
    Bresolin, Andrea
    Gallo, Pasqualina
    La Fauci, Francesco
    Lobefalo, Francesca
    Paganini, Lucia
    Reggiori, Giacomo
    Loiacono, Daniele
    Franzese, Ciro
    Tomatis, Stefano
    Scorsetti, Marta
    Mancosu, Pietro
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [28] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Ce Han
    Ji Zhang
    Bing Yu
    Haoze Zheng
    Yibo Wu
    Zhixi Lin
    Boda Ning
    Jinling Yi
    Congying Xie
    Xiance Jin
    Radiation Oncology, 18
  • [29] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184
  • [30] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy vs Intensity Modulated Radiation Therapy for Anal Cancer
    Hibbitts, K.
    Chiang, B.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E623 - E623