Annihilation gamma imaging for carbon ion beam range monitoring using Si/CdTe Compton camera

被引:30
|
作者
Parajuli, Raj Kumar [1 ]
Sakai, Makoto [1 ]
Kada, Wataru [2 ]
Torikai, Kota [1 ]
Kikuchi, Mikiko [1 ]
Arakawa, Kazuo [1 ]
Torikoshi, Masami [1 ]
Nakano, Takashi [1 ]
机构
[1] Gunma Univ, Heavy Ion Med Ctr, 3-39-22 Showa Machi, Maebashi, Gunma, Japan
[2] Gunma Univ, Grad Sch Sci & Technol, 1-5-1 Tenjin Cho, Kiryu, Gunma, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 05期
关键词
carbon ion radiotherapy; annihilation gamma imaging; compton camera; Beam monitoring; TUMOR-THERAPY; BRAGG PEAK; PROTON; VERIFICATION; RESOLUTION; EMISSION; PARTICLE;
D O I
10.1088/1361-6560/ab00b2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we performed on-beam monitoring of 511 keV annihilation gamma emissions using a Compton camera. Beam monitoring experiments were conducted using carbon ion beams of 290 MeV/u irradiated on a polymethyl methacrylate (PMMA) phantom. The intensity of the beams was 3 x 10(9) particles per pulse, with 20 pulses per minute. A Compton camera based on a silicon/cadmium telluride (Si/CdTe) detector was used to monitor the annihilation gamma rays emitted from the phantom. We successfully reconstructed the energy events of 511 keV annihilation gamma rays and developed Compton images using a simple back-projection method. The distribution of the annihilation gamma ray generation traced the beam trajectory and the peak intensity position was a few millimeters shorter than the Bragg peak position. Moreover, the effect of the beam range shifter with 30, 60, and 90 mm water equivalent thickness (WET) was clearly visualized in the reconstructed Compton images. The experimentally measured values of the corresponding range shifts in the PMMA phantom (28.70 mm, 52.49 mm, and 76.77 mm, respectively) were consistent with the shifts of the Bragg peak position (25.50 mm, 51.30 mm and 76.70 mm, respectively) evaluated by Monte Carlo simulation. The results show that the Si/CdTe Compton camera has strong potential for on-beam monitoring of annihilation gamma rays in particle therapy in clinical situations.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] IMAGING OF POINT SOURCES WITH A COMPTON CAMERA FOR IN-VIVO DOSE MONITORING OF ION BEAM IRRADIATION
    Kormoll, T.
    Fiedler, F.
    Golnik, C.
    Heidel, K.
    Kempe, M.
    Schoene, S.
    Sobiella, M.
    Zuber, K.
    Enghardt, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S41 - S42
  • [12] Test of Compton camera components for prompt gamma imaging at the ELBE bremsstrahlung beam
    Hueso-Gonzalez, F.
    Golnik, C.
    Berthel, M.
    Dreyer, A.
    Enghardt, W.
    Fiedler, F.
    Heidel, K.
    Kormoll, T.
    Rohling, H.
    Schoene, S.
    Schwengner, R.
    Wagner, A.
    Pausch, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [13] Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification
    Gutierrez, A.
    Baker, C.
    Boston, H.
    Chung, S.
    Judson, D. S.
    Kacperek, A.
    Le Crom, B.
    Moss, R.
    Royle, G.
    Speller, R.
    Boston, A. J.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [14] Tomographic Imaging by a Si/CdTe Compton Camera for 111In and 131I Radionuclides
    Yabu, Goro
    Yoneda, Hiroki
    Orita, Tadashi
    Takeda, Shin'ichiro
    Caradonna, Pietro
    Takahashi, Tadayuki
    Watanabe, Shin
    Moriyama, Fumiki
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (05) : 592 - 600
  • [15] Monte Carlo Simulation of Multi-Head Si/CdTe Compton Camera for Medical Imaging
    Yamaguchi, M.
    Kawachi, N.
    Watanabe, S.
    Odaka, H.
    Takeda, S.
    Ishikawa, S.
    Aono, H.
    Takahashi, T.
    Arakawa, K.
    Nakano, T.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3275 - +
  • [16] Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility
    Fontana, M.
    Ley, J. -L.
    Dauvergne, D.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Maxim, V.
    Richard, M. -H.
    Rinaldi, I.
    Testa, E.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 218 - 232
  • [17] Imaging of 99mTc-DMSA and 18F-FDG in humans using a Si/CdTe Compton camera
    Nakano, Takashi
    Sakai, Makoto
    Torikai, Kota
    Suzuki, Yoshiyuki
    Takeda, Shin'ichiro
    Noda, Shin-ei
    Yamaguchi, Mitsutaka
    Nagao, Yuto
    Kikuchi, Mikiko
    Odaka, Hirokazu
    Kamiya, Tomihiro
    Kawachi, Naoki
    Watanabe, Shin
    Arakawa, Kazuo
    Takahashi, Tadayuki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [18] Design Study of a Compton Camera for Prompt γ Imaging During Ion Beam Therapy
    Richard, M. -H.
    Chevallier, M.
    Dauvergne, D.
    Freud, N.
    Henriquet, P.
    Le Foulher, F.
    Letang, J. M.
    Montarou, G.
    Ray, C.
    Roellinghoff, F.
    Testa, E.
    Testa, M.
    Walenta, A. H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4172 - +
  • [19] SUBMILLIMETER NUCLEAR MEDICAL IMAGING WITH A COMPTON CAMERA USING TRIPLE COINCIDENCES OF COLLINEAR BETA plus -ANNIHILATION PHOTONS AND GAMMA RAYS
    Lang, C.
    Habs, D.
    Thirolf, P.
    Zoglauer, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S30 - S30
  • [20] The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
    Watanabe, Shin
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    Ichinohe, Yuto
    Takeda, Shin'ichiro
    Enoto, Teruaki
    Fukuyama, Taro
    Furui, Shunya
    Genba, Kei
    Hagino, Kouichi
    Harayama, Atsushi
    Kuroda, Yoshikatsu
    Matsuura, Daisuke
    Nakamura, Ryo
    Nakazawa, Kazuhiro
    Noda, Hirofumi
    Odaka, Hirokazu
    Ohta, Masayuki
    Onishi, Mitsunobu
    Saito, Shinya
    Sato, Goro
    Sato, Tamotsu
    Takahashi, Tadayuki
    Tanaka, Takaaki
    Togo, Atsushi
    Tomizuka, Shinji
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 765 : 192 - 201